Example: dental hygienist

heat-flex hi-temp 1200 7.10 - Sherwin Williams …

Revised 8/12 heat - flex hi-temp 1200 COATING UNDER INSULATION B59A225 GRAY B59A226 DARK GRAYP rotective & DESCRIPTIONHEAT- flex hi-temp 1200 is the next generation single-component inert multipolymeric matrix coating that outperforms alternatives in combating corrosion under insulation (CUI) and in high heat applications.

7.10 HEAT-FLEX® HI-TEMP 1200 COATING UNDER INSULATION Marine B59A225 GRAY B59A226 DARK GRAY Protective & Coatings www.sherwin-williams.com/protective SURFACE PREPARATION Surface …

Tags:

  2010, Heat, Flex, Temp, Heat flex hi temp 1200, Heat flex, 174 hi temp 1200

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of heat-flex hi-temp 1200 7.10 - Sherwin Williams …

1 Revised 8/12 heat - flex hi-temp 1200 COATING UNDER INSULATION B59A225 GRAY B59A226 DARK GRAYP rotective & DESCRIPTIONHEAT- flex hi-temp 1200 is the next generation single-component inert multipolymeric matrix coating that outperforms alternatives in combating corrosion under insulation (CUI) and in high heat applications.

2 Resists corrosion under insulation Resists stress corrosion cracking Application surface temperatures from ambient to 500 F (260 C) Operating surface temperatures cryogenic to 1200 F (649 C) heat curing not required to cure and provide corrosion resistance Self priming, single component No maximum recoat timePRODUCT CHARACTERISTICSF inish: Low SheenColor: Gray and Dark GrayVolume Solids: 57% 2% (calculated) Weight Solids: 81% 2% VOC (EPA Method 24): <375 g/L; lb/galRecommended Spreading Rate per coat:MinimumMaximumWet mils (microns) (200) (250)Dry mils (microns) (125) (150)~Coverage sq ft/gal (m2/L)152( )182( )Theoretical coverage sq ft/gal (m2/L) @ 1 mil / 25 microns dft912( )NOTE: Brush or roll application may require multiple coats to achieve maximum fi lm thickness and uniformity of Schedule @ mils wet (200 microns):@ 50 F/10 C@ 77 F/25 C@ 120 F/49 C50% RHTo touch:30 minutes20 minutes10 minutesTo handle:90 minutes60 minutes30 minutesTo recoat:3 hours2 hours1 hourTo ship.

3 24 hours*24 hours24 hours*Higher fi lm build effects cure speed and increases ship time at lower time is temperature, humidity, and fi lm thickness Life:12 months, unopened at 77 F (25 C)Store indoors at 40 F ( C) to 100 F (31 C)Flash Point: 87 F (31 C) SETAR educer:Not normally recommended*Clean Up:Xylene, R2K4*Please see Performance Tips section continued on backRECOMMENDED USES Direct to steel or stainless steel As a coating under insulation Cyclic service up to 1200 F (649 C) Acceptable for use on cryogenic equipment For use over properly prepared steel surfaces, either insulated or uninsulated: Power Plants Refi neries Chemical Facilities Offshore/Marine Pulp & PaperPERFORMANCE CHARACTERISTICSS ubstrate.

4 Carbon Steel / Stainless Steel, 304, 316 Surface Preparation: SSPC-SP10 System Tested: 2 cts. heat - flex hi-temp 1200 @ 5-6 mils (125-150 microns) NameTest MethodResultsAbrasion ResistanceASTM D968, Falling L/mil*AbrasionResistanceASTM D4060, Milligram Loss189 AdhesionASTM D6677 Rating 10 Blocking ResistanceASTM D4946 Rating 10 Boiling WaterDry 1000 F/537 CWet 210 F/99 C16 weeks, 80 cyclesNo adhesion lossCorrosion Under Insulation (Carbon Steel)Dry 350 F/177 CWet 150 F/66 C12 weeks, 6 cycles (calcium silicate and mineral wool)Rating 10 per ASTM D714 for blistering.

5 Rating 10 per ASTM D610 for rustingCorrosion Weathering (Carbon Steel)ASTM D5894, 8 cycles, 2,688 hoursRating 10 per ASTM D714 for blistering; Rating 10 per ASTM D610 for rustingDirect ImpactResistanceASTM D279480 in lbDry heat ResistanceASTM D24851200 F (649 C)Exterior Durability (Carbon Steel)1 year at 45 SouthIn-ProcessFlexibilityASTM D522, 180 bend, 1 " mandrelPassesPencil HardnessASTM D33632 HSalt Fog Resistance (Carbon Steel)ASTM B117, 1,848 hoursRating 10 per ASTM D714 for blistering; Rating 8 per ASTM D610 for rusting*Falling sand is very practical for indication of coating abrasion in the fi hi-temp 1200 COATING UNDER INSULATION B59A225 GRAY B59A226 DARK GRAYP rotective & PREPARATIONS urface must be clean, dry, and in sound condition.

6 Remove all oil, dust, grease, dirt, loose rust, and other foreign material to ensure adequate to product Application Bulletin for detailed surface prepara-tion recommended surface preparation: Iron & Steel: SSPC-SP6, mil (40-63 micron) profi le Or SSPC-SP11, mil (25-63 micron) profi le Stainless Steel: SSPC-SP1, Do not use chlorinated solvents for cleaningSurface Preparation StandardsCondition of SurfaceISO 8501-1BS7079:A1 Swedish NACEW hite MetalSa 3Sa 3SP 51 Near White MetalSa 10 2 Commercial BlastSa 2Sa 2SP 63 Brush-Off BlastSa 1Sa 1SP 74 Hand Tool CleaningRustedC St 2C St 2SP 2-Pitted & Rusted D St 2D St 2SP 2-Power Tool CleaningRustedC St 3C St 3SP 3-Pitted & Rusted D St 3D St 3SP 3-TINTINGDo not CONDITIONST emperature: surface 50 F (10 C) minimum, 500 F (260 C) maximum air and material 50 F (10 C) minimum, 120 F (49 C) maximum At least 5 F ( C) above dew pointRelative humidity.

7 85% maximumRefer to product Application Bulletin for detailed application INFORMATIONP ackaging: 1 gallon ( ) in a gallon ( ) container and 3 gallons ( ) in a 5 gallon ( ) : lb/gal ; Kg/LSAFETY PRECAUTIONSR efer to the MSDS sheet before technical data and instructions are subject to change without notice. Contact your Sherwin - Williams representative for additional technical data and Sherwin - Williams Company warrants our products to be free of manufactur-ing defects in accord with applicable Sherwin - Williams quality control procedures.

8 Liability for products proven defective, if any, is limited to replacement of the defec-tive product or the refund of the purchase price paid for the defective product as determined by Sherwin - Williams . NO OTHER WARRANTY OR GUARANTEE OF ANY KIND IS MADE BY Sherwin - Williams , EXPRESSED OR IMPLIED, STATUTORY, BY OPERATION OF LAW OR OTHERWISE, INCLUDING MER-CHANTABILITY AND FITNESS FOR A PARTICULAR INFORMATIONRECOMMENDED SYSTEMS Dry Film Thickness / ct. Mils (Microns)Carbon Steel or Stainless Steel - Atmospheric: Ambient or Hot Steel up to 500 F/260 C* :2 cts.

9 heat - flex hi-temp 1200 (125-150)Carbon Steel or Stainless Steel - Insulated Service: Ambient or Hot Steel up to 500 F/260 C* :2 cts. heat - flex hi-temp 1200 (125-150)*During application to hot steel, apply coating in several thinpasses to allow solvent to escape and to prevent at least 15-20 minutes between each systems listed above are representative of the product's use, other systems may be information and recommendations set forth in this Product Data Sheet are based upon tests conducted by or on behalf of The Sherwin - Williams Company.

10 Such information and recommendations set forth herein are subject to change and pertain to the product offered at the time of publication. Consult your Sherwin - Williams representative to obtain the most recent Product Data Information and Application 8/12 heat - flex hi-temp 1200 COATING UNDER INSULATION B59A225 GRAY B59A226 DARK GRAYP rotective & PREPARATIONSS urface must be clean, dry, and in sound condition.


Related search queries