Example: barber

Heating Basics – Gas Valve Systems

2010 Invensys. All Rights names, logos, and taglines identifying the products and services of Invensys are proprietary marks of Invensys or its subsidiaries. All third party trademarks and service marks are the proprietary marks of their respective Basics Gas Valve SystemsUNI-LINE PRODUCT KNOWLEDGES ubjects We Will Cover In This Session Fuel and Pressure Characteristics Gas Valve Applications Gas Valve Actuator Types Gas Valve Characteristics Gas Valve Manufacturers Ignition control System Ignition Manufacturers Flame Rectification Pilot Basics Thermocouple and Thermopile Basics Installation and Troubleshooting Tips Website Tools When You Have Questions Q&A2 AcronymsBTU=British Thermal UnitsLC=Low CapacityLP=Liquid PropaneMV =

Ignition Control System 1. Thermostat calls for heat 2. Ignition controller requests a spark to the electrode which ignites the gas 3. Control uses flame rectification or sensor to identify if flame is present 4. Ignition controller sends signal to open gas valve 5. When thermostat is satisfied, gas valve closes to shut off main burner gas 28

Tags:

  Control, Valves

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Heating Basics – Gas Valve Systems

1 2010 Invensys. All Rights names, logos, and taglines identifying the products and services of Invensys are proprietary marks of Invensys or its subsidiaries. All third party trademarks and service marks are the proprietary marks of their respective Basics Gas Valve SystemsUNI-LINE PRODUCT KNOWLEDGES ubjects We Will Cover In This Session Fuel and Pressure Characteristics Gas Valve Applications Gas Valve Actuator Types Gas Valve Characteristics Gas Valve Manufacturers Ignition control System Ignition Manufacturers Flame Rectification Pilot Basics Thermocouple and Thermopile Basics Installation and Troubleshooting Tips Website Tools When You Have Questions Q&A2 AcronymsBTU=British Thermal UnitsLC=Low CapacityLP=Liquid PropaneMV =

2 Main ValveNAT=Natural GasPD=Pressure DropPV = Pilot ValveSLC=Snap-action Low CapacitymV=milliVoltsWC=Water Column3 Fuel Characteristics Natural gas is lighter than air and rises gas is heavier and puddlesin the lowest area it can findNatural GasCharacteristicsLiquid Propane (LP) / Cubic Feet25007 WC WCService Pressure Range11 WC 14 WC1200 FIgnition Temperature950 F10/1 Combustion Air/Gas Ratio24/14 Fuel Characteristics of British Thermal Units Definition of BTU: The quantity of heat required to raise the temperature of one pound of water one degree Fahrenheit Many gas appliances are rated depending on BTU output The more heat needed, the higher the BTU rating Residential gas water heaters (regardless of fuel)

3 Are rated between 15,000 and 75,000 BTU Over 75,000 BTU is considered Commercial Water Heater Commercial Water Heaters rated between 75,000 and 750,000 BTU5 Pressure Characteristics Excessive inlet pressure will not necessarily cause the gas Valve to lock up However, the Valve will not regulate pressure correctly Gas line pressure from utilities vary seasonally with demand During peak usage, inlet pressure can drop below the 7 WC Natural gas shown above High rise buildings may experience low pressure on upper floors Especially during cold weather, many times a 2 psig system is used to compensate In some instances OEMs will specify higher outlet pressures To obtain BTU rates beyond the capabilities of the gas Valve at 1 pressure dropPressure SideNatural GasLiquid PropaneInlet Pressure7 10 WC14 17 WCOutlet Pressure3 4 WC @ 1 PD10 11 WC @ 1 PD6 Central Heating ApplicationsFactory Model(Uni-Line Part)BTU @ 1 PDMin - Max BTU CapacityStandingIntermittentDirect7000 STD(Uni-Line 700)Nat 300,00010,000 720,000999LP 485,00010,000 900,0009997000 HC(Uni-Line 700)

4 Nat 600,000200,000 800,000999LP 972,000300,000-1,150,0009997200(Uni-Line 720)Nat 150,00015,000 200,000999LP 240,00015,000 320,0009997 Space Heating And Hearth ApplicationsFactory ModelBTU @ 1 PDMin - Max BTU CapacityStandingIntermittentDirect7000 STD(Uni-Line 700)Nat 300,00010,000 720,000999LP 485,00010,000 900,0009997200(Uni-Line 720)Nat 150,00015,000 200,000999LP 240,00015,000 320,0009992000(Uni-Line 722)Nat 125,00025,000 170,000899LP 200,00025,000 272,0008997500 (Uni-Line 722)Nat 100,0006,700 160,000988LP 162,0006,700 226,0009887000 LC (Uni-Line 710)Nat 40,0005,000 70,000988LP 65,0005,000 100,0009887000 ST(Uni-Line 700)Nat 100,00010,000 160,000988LP 162,00010,000 225,0009888 Commercial Water Heating ApplicationsFactory ModelBTU @ 1 PDMin - Max BTU CapacityStandingIntermittentDirect7000 STD(Uni-Line 700)Nat 300,00010,000 720,000999LP 485,00010,000 900,0009997200(Uni-Line 720)Nat 150,00015,000 200,000999LP 240,00015,000 320,0009992000(Uni-Line 722)Nat 125,00025,000 170,000899LP 200,00025,000 272,0008997000 HC (Uni-Line 700)

5 Nat 600,000200,000 800,000999LP 972,000300,000 1,150,0009999 Commercial Cooking ApplicationsFactory ModelBTU @ 1 PDMin - Max BTU CapacityStandingIntermittentDirectTemp Rating7000 STD(Uni-Line 700)Nat 300,00010,000 720,000999-40 to 175 FLP 485,00010,000 900,0009997200(Uni-Line 720)Nat 150,00015,000 200,000999-40 to 175 FLP 240,00015,000 320,0009992000(Uni-Line 722)Nat 125,00025,000 170,000899-40 to 175 FLP 200,00025,000 272,0008997500 (Uni-Line 722)Nat 100,0006,700 160,0009880 to 185 FLP 162,00012,000 226,0009887000 LC (Uni-Line 710)Nat 40,0005,000 70,000988-40 to 225 FLP 65,0005,000 100,000988TS11 J &K(Uni-Line 700)Nat 210,000NA98832 to 300 FLP 340,000NA98810 Residential Water Heating ApplicationsFactory ModelBTU @ 1 PDMin - Max BTU CapacityStandingIntermittentDirectTemp Rating220R(Uni-Line 110)Nat 86,00010,700 107,00098832 to 175 FLP 100,0007,000 140,000988R103RV(Uni-Line 110)Nat NANA98832 to 175 FLP > 35,0003,500 35,0009882000(Uni-Line 722)Nat 125,00025,000 170,000899-40 to 175 FLP 200,00025,000 272,000899R110R(Uni-Line 110)

6 Nat 86,00010,700 107,00098832 to 175 FLP 100,0007,000 140,00098811 Gas Valve Actuator Types Manual Standing pilot Valve manually turned ON and OFF for each Heating cycle. Millivolt Wall thermostat actuated with manual gas cock, automatic pilot safety Valve and a Millivolt operator. The automatic pilot safety is separate from gas cock and provides shutoff in case of pilot outage. Millivolt gas valves do not require external power source. 24 Volt, 120 Volt, and 240 Volt Combines a manual main and pilot gas Valve , a separate automatic safety pilot Valve , pilot filtration, and automatic electric Valve .

7 Hydraulic Temperature is sensed by a capillary bulb. The bulb in the return air stream is actuated open and close by the hydraulic CockPilot andThermopileECO Limit(Energy Cut Off)SafetyWall ThermostatOperatorPilot Line Millivolt Actuated Gas Valve13TH/TPTHTPTHTPOPERATOROPERATORRWRW TP1950 SeriesTwo-LeadThermopile1951 SeriesCoaxialThermopileSafetyMagnetSafet yMagnetTH/TPRobertshaw 700 & 710 Millivolt Wiring14 Gas CockPilot andThermocoupleECO(Limit)Wall ThermostatOperatorFan control NOHigh Limit NCTransformer120 VAC24 VACFanMotorMost popular Uni-Line part is 710-402, Factory Part7000-ERLC24 Volt Actuated Standing Pilot System15 Gas CockPilot andThermocoupleECO(Limit)

8 56F LO 1 2 3 4 5 6 7 8 HI 90 FTemperatureControl KnobSafetySensing BulbHydraulic Actuated Standing Pilot System16 Additional Gas Valve Characteristics Combination Gas valves Open Valve Options Standard Opening Slow Opening Step Opening Two-stage Models Close Valve Options Snap Action Snap Throttle17 Combination Gas ValvesCombination valves include three components Regulation Safety Valve Main Valve actuated by thermostat or bulb18 Additional Gas Valve CharacteristicsRobertshaw Gas Valve Opening Characteristics050,000100,000150,000200, 000250,000300,000350,000400,000450,0000 1 5 10152025303540 Time (s)BTUS tandard OpenSlow OpenStep OpenLEGENDOPENING CHARACTERISTICSSTANDARD OPEN instant full flowSLOW OPENS7A = 0 - 5 sec.

9 To full flowS7B = 5 - 10 sec. to full flowS7C = 10 - 30 sec. to full flowSTEP OPENSO1 = 30% of full flowSO2 = 40% of full flowSO3 = 50% of full flowSO4 = 60% of full flowSO5 = 70% of full flow19 Additional Characteristics for Two-Stage Robertshaw two-stage gas valves use a two-stage, two-pressure regulator which responds to a two-stage controller (thermostat) Available in capacities from 29,000 to 960,000 BTU/Hr Piping sizes from 3/8 to 1 inch Can be used with either natural gas or liquid propane Two-stage has the ability to vary the gas pressure delivered to the main burner(s) through the use of a solenoid operated two-pressure regulator First stage actuator of the gas Valve is energized When heat demand increases.

10 The second stage regulator is energized First stage setting is determined as a percentage of the full output of the Valve and is factory set Second stage pressure regulator setting is nominal WC for natural gas and 11 for LP20 Snap-Action And Snap-Throttle Hydraulic Valves21 Gas Valve ManufacturersAttributesRobertshaw HoneywellWhite-RodgersDexenSITUS Based Engineering99988US Based Technical Services99888 Space & Central99999 Residential Water99988 Hearth Products99899 Pilot, Thermocouple and Ignition Controls9998 922 Ignition control Systems Standing Pilot Intermittent Pilot Ignition (IPI) Direct Spark Ignition (DSI) Hot Surface Ignition (HSI)23 Four Types of Ignition Systems Standing pilot Pilot is manually ignited and stays on constantly.