Example: bankruptcy

Helical Coil Heaters - CEI Enterprises

Helical Coil HeatersHelical Coil HeatersCEI EnterprisesHC-SERIES HEATER WITH MANIFOLD FOR MULTIPLE CIRCUITS2 OPERATION & FEATURESABCS tandard model without stack heat exchangerHCS-series heaterFillOverflow PipeControl PanelExpansion TankLow Level ControlCoil OutletOil ReturnHelical CoilCoil InletStack Heat Exchanger (optional)Full Modulation BurnerCirculating PumpDHelical Coil Hot Oil HeatersHelical Coil Heaters are available in two basic configurations: HCS-series for single hot oil circuits, and HC-series for multiple hot oil circuits. Four standard models are available in each series, with outputs from million to 4 million Btu/hour. All Heaters can be customized to meet your specific Circuit Systems: Small plants with only one or two liquid asphalt tanks usually need only one hot oil circuit with one pump.

TEMPERATURE CONTROLLERS & DIGITAL ANNUNCIATOR HELICAL COIL HC-SERIES HEATER WITH MANIFOLD FOR MULTIPLE CIRCUITS 2 3 General Dimensions and Specifi cations

Tags:

  Heaters, Coils, Helical, Helical coil heaters

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Helical Coil Heaters - CEI Enterprises

1 Helical Coil HeatersHelical Coil HeatersCEI EnterprisesHC-SERIES HEATER WITH MANIFOLD FOR MULTIPLE CIRCUITS2 OPERATION & FEATURESABCS tandard model without stack heat exchangerHCS-series heaterFillOverflow PipeControl PanelExpansion TankLow Level ControlCoil OutletOil ReturnHelical CoilCoil InletStack Heat Exchanger (optional)Full Modulation BurnerCirculating PumpDHelical Coil Hot Oil HeatersHelical Coil Heaters are available in two basic configurations: HCS-series for single hot oil circuits, and HC-series for multiple hot oil circuits. Four standard models are available in each series, with outputs from million to 4 million Btu/hour. All Heaters can be customized to meet your specific Circuit Systems: Small plants with only one or two liquid asphalt tanks usually need only one hot oil circuit with one pump.

2 HCS-series Heaters are well-suited for such plants. One circulating pump, mounted on the heater skid, circulates the heat transfer oil through the heater and through heated plant Circuit Systems: Plants with storage silos, multiple asphalt tanks, and additional components can usually benefit from using multiple hot oil circuits. HC-series Heaters are designed for such applications. They feature a manifold on the output connection that supplies oil to multiple additional pumps. Each of these side pumps is dedicated to an independent hot oil multiple circuits reduces the load on each pump, its motor, and its operating pressure. This system is much more flexible than a single-circuit system because each circuit can be operated independently.

3 Centrifugal Circulating Pump, mounted on the heater skid, circulates heat transfer oil through the heater. Viton shaft seal rings provide a reliable seal with virtually no the heater is equipped with an optional stack heat exchanger, the oil first enters the exchanger, where it is heated by hot exhaust gases. Oil then exits the stack heat exchanger and enters the Helical coil, where it is heated by hot gases from the Burner conserves fuel, reduces temperature overshooting and eliminates constant on-off burner burner fires into the open center of the Helical coil, creating the first pass of hot burner gases. Burner gases then turn at the end of the coil, making a second pass along the coil s outer CONTROLLERS & DIGITAL ANNUNCIATORHELICAL COIL3 General Dimensions and SpecificationsHeater ModelOutput Btu/hrMax.

4 Fuel UsagePump Motor HPVolume Flow Rate (gpm)Expansion Tank (gallons)LengthAWidthBHeightCPipe SizeDApproximate Weight (lbs) (gph)Gas (cfph)Single-Circuit HeatersHCS-1001,200,000111,5601010017512 -9 5 -10 8 -11 2 5,000 HCS-1752,000,000182,6001515028014 -9 6 -4 9 -9 2-1/2 6,500 HCS-2503,000,000273,9001515028015 11 7 -4 10 -6 3 9,300 HCS-3504,000, -7 8 -2 11 -2 3 10,700 Multi-Circuit HeatersHC-1201,200,000111,5601010017512 -9 6 -8 8 -11 2 5,100HC-2002,000,000182,6001515028014 -10 6 -6 9 -9 2-1/2 6,600HC-3003,000,000273,9001515028015 -11 7 -6 10 -6 3 9,500HC-4004,000,000365,2001520040018 -7 8 -4 11 -2 3 amount of fuel used is for a thermal efficiency of 85% and one hour of operation at maximum output.

5 A properly sized heater normally runs for intermittent periods at lower outputs. No. 2 fuel usage is based on 132,000 Btu per gallon, its LHV (low heating value). Natural gas usage is based on 905 Btu per cubic foot, its LHV. Heights include the exhaust stack without a stack heat exchanger. The stack heat exchanger for the HCS-350 and HC-400 weighs 800 pounds and adds 2 -7 to their height. For all other models it weighs 460 pounds and adds 1 -9 to their height. NOTE: Specifications are subject to change without prior notice or OutletHelical Coil Hot Oil HeatersHelical Coil is designed and built to ASME code. It is designed to provide a large heat transfer surface area, low flux rates, and an ideal fluid velocity of 7 to 11 feet per second.

6 ASME stamp is available as an option. Stack Heat Exchanger is an available option that can boost the heater s thermal efficiency by 5%. Hot burner gases exiting the heater pass around a densely packed set of serrated finned tubes inside the heat exchanger. Thermal oil flowing inside the tubes is heated before entering the Helical option reduces fuel usage by reducing the output demand placed on the burner. This can reduce fuel consumption by 261 gallons of fuel oil or 345 therms of natural gas per month. A stack heat exchanger usually pays for itself in one year, or , NEMA 4 Control Panel is the nerve center of the heater s temperature control and safety systems.

7 Compliance to UL standards not only assures you of the quality of the electrical system, it also puts your insurance company at ease, potentially bringing you lower premiums. The NEMA 4 enclosure provides watertight protection against splashing water, hose-directed water, rain, sleet, snow, ice, dirt, and windblown that meet CSA specifications, and other NEMA standard enclosures are available Controllers: Two microprocessor-based controllers provide control over output temperatures. The Temperature Controller regulates the flow of fuel and combustion air to the burner to efficiently maintain the temperature set point on the High Media Controller is a safety control.

8 It will shut down the burner if the heat transfer oil reaches the temperature limit set on this Monitor is a microprocessor-based burner management control system. The monitor provides proper burner sequencing, ignition and flame monitoring protection. In conjunction with limit and operating controls it sequences the burner/blower motor, ignition, and fuel valves to provide for proper and safe burner operation. Other features include: Self-diagnostic for safety and reliability. Non-volatile memory retains information even when power is interrupted. Microprocessor-based for accurate timing, comprehensive diagnostics and precision control. 4 EfficiencyGallons / hourGallons / MonthGallons / Life 50% ,8302,020,96960% ,0081,680,80670% ,7731,450,48480% ,8151,271,66185% ,4061,195,30788% ,1981,156,565 These usages are based on a 1-million Btu/hr heat load, operating 24 hrs/day, 7 days/week, 40 weeks/yr, a 20 year heater life and No.

9 2 fuel oil with a heating value of 132,000 Btu/gallon (LHV).HCS-SERIES HEATER FOR SINGLE HOT OIL CIRCUIT. SHOWN WITH OPTIONAL STACK HEAT Coil Hot Oil HeatersDigital Annunciator visible on the front of the control panel displays heater status at all times. Any safety limit that is exceeded will immediately shut down the burner. The cause will be clearly displayed on the LCD screen, reducing down time and assisting CEI Service personnel diagnose any heater issues remotely, if necessary. Wireless Monitoring Systems are optionally available for additional convenience and reduced down time. These systems communicate any heater shut-down issues to your cell phone, so you will know what s happening with your heater, no matter where you : The Heaters operate on natural gas, LPG, or No.

10 2 commercial grade fuel oil, depending on the burner used. An optional combination burner allows switching between two different Efficiency: Aside from safety and reliability, thermal efficiency is probably the most important aspect of any heater. CEI s Helical coil heater approaches the theoretical limits of thermal efficiency possible in a fired 2-pass heater. Even without the stack heat exchanger, its efficiency is 85 Transfer Fluid SpecsThe heat transfer oil should be paraffin base, solvent refined and recommended for operating temperature to 450 : Do not mix paraffin base oils with aromatic base oils. Mixing will clog and severely damage the heater and heating API28-30 Flash Point420 FViscosity at 100 F200 SSUV iscosity at 210 F50 SSUV iscosity Index95 Point5 FCarbon Options: Low-NOx burners (30ppm).