Control valvesTechnical dataMedium:Filtered, non-lubricated and driedcompressed air, instrument air, nitrogenand or other non-flammable neutral, dryfluidsOperating pressure:2,5 to 8 bar with internal air supply0 to 8 bar with external air supplyMounting position:Optional; impulse valves preferablyhorizontallyAmbient temperature:Valve: -40 C to +65 CSolenoid: see solenoid tableFor temperatures below 0 C use conditioned dry air. If installedoutdoors protect all connections against the penetration ofmoisture Consult our Technical Service for use below +2 CMaterialsBody: aluminium surface treatment for roughenvironmental conditions Condensate test with alternatingtemperatures in sulphuric environment, Salt spray test with different sodiumchloride solutions, tested in ammoniaenvironmentSeals: NBR (S)

145 Herion 97105 In-line Series Indirect solenoid actuated soft seal spool valves For single and double acting actuators 6 mm orifice (ND) 3/2, 5/2, 5/3, NC/APB, GÊ, Ê …

Tags:

  Series, Line, Herion 97105 in line series, Herion, 97105

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Herion 97105 In-line Series - IMI Precision

1 Control valvesTechnical dataMedium:Filtered, non-lubricated and driedcompressed air, instrument air, nitrogenand or other non-flammable neutral, dryfluidsOperating pressure:2,5 to 8 bar with internal air supply0 to 8 bar with external air supplyMounting position:Optional; impulse valves preferablyhorizontallyAmbient temperature:Valve: -40 C to +65 CSolenoid: see solenoid tableFor temperatures below 0 C use conditioned dry air. If installedoutdoors protect all connections against the penetration ofmoisture Consult our Technical Service for use below +2 CMaterialsBody: aluminium surface treatment for roughenvironmental conditions Condensate test with alternatingtemperatures in sulphuric environment, Salt spray test with different sodiumchloride solutions, tested in ammoniaenvironmentSeals.

2 NBR (Special perbunan)CCrroossssoovveerr--ffrreeee sswwiittcchhiinngg,, sswwiittcchh--oovveerrffuunnccttiioonn gguuaarraanntteeeedd eevveenn wwiitthh ssmmaallll ccrroosssssseeccttiioonnRReesstt ppoossiittiioonn iinn tthhee eevveenntt ooff ppoowweerr ffaaiilluurreepprroovviiddeedd bbyy mmeecchhaanniiccaall rreettuurrnn sspprriinngg((mmoonnoossttaabbllee)) ddeessiiggnnAAdddd--oonn mmaannuuaall oovveerrrriiddeeSSuuiittaabbllee ffoorr oouuttddoooorr iinnssttaallllaattiioonn iiff eeqquuiippppeeddwwiitthh ccoorrrreessppoonnddiinngg ssoolleennooiiddMMiinniimmaall eelleeccttrriiccaall ppoowweerr ccoonnssuummppttiioonn tthheerreeffoorree mmaannyy pprrootteeccttiioonn ccllaasssseess ppoossssiibbllee,, EEEExx iiSSoolleennooiiddss aarree AATTEEXX aanndd FFMM,, CCSSAA,, XXPP aapppprroovveeddG 1/43/2 Solenoid/Spring1,300,519713535xxxx**G 1/23/2 Solenoid/Spring2,600.

3 529713555xxxx**G 1/45/2 Solenoid/Spring1,300,739710535xxxx**G 1/25/2 Solenoid/Spring2,600,749710555xxxx**G 1/45/2 Solenoid/Solenoid1,300,759711535xxxx**G 1/45/3 Solenoid/Solenoid mid position APB 0,950,7 69712535xxxx**1/4 NPT3/2 Solenoid/Spring1,300,519713545xxxx**1/2 NPT3/2 Solenoid/Spring2,600,529713565xxxx**1/4 NPT5/2 Solenoid/Spring1,300,739710545xxxx**1/2 NPT5/2 Solenoid/Spring2,600,749710565xxxx**1/4 NPT5/2 Solenoid/Solenoid1,300,759711545xxxx**1/ 4 NPT5/3 Solenoid/Solenoid mid position APB 0,950,7 69712545xxxx**Port sizekgDrawing value (m3/h)*FunctionActuationPort sizekgDrawing value (m3/h)

4 *FunctionActuationG 1/43/2 Solenoid/Spring1,301,019713635xxxx**G 1/23/2 Solenoid/Spring2,601,029713655xxxx**G 1/45/2 Solenoid/Spring1,301,739710635xxxx**G 1/25/2 Solenoid/Spring2,601,749710655xxxx**G 1/45/2 Solenoid/Solenoid1,301,759711635xxxx**1/ 4 NPT3/2 Solenoid/Spring1,301,019713645xxxx**1/2 NPT3/2 Solenoid/Spring2,601,029713665xxxx**1/4 NPT5/2 Solenoid/Spring1,301,739710645xxxx**1/2 NPT5/2 Solenoid/Spring2,601,749710665xxxx**1/4 NPT5/2 Solenoid/Solenoid1,301,759711645xxxx**G 1/43/2 Solenoid/Spring1,301,119713735xxxx**G 1/23/2 Solenoid/Spring2,601,129713755xxxx**G 1/45/2 Solenoid/Spring1,301,839710735xxxx**G 1/25/2 Solenoid/Spring2,601,849710755xxxx**G 1/45/2 Solenoid/Solenoid1,301,859711735xxxx**1/ 4 NPT3/2 Solenoid/Spring1,301,119713745xxxx**1/2 NPT3/2 Solenoid/Spring2,601,129713765xxxx**1/4 NPT5/2 Solenoid/Spring1,301,839710745xxxx**1/2 NPT5/2 Solenoid/Spring2,601,849710765xxxx**1/4 NPT5/2 Solenoid/Solenoid1,301,859711745xxxx**xx xx Insert solenoid codes from table below.

5 ** Insert voltage codes from table below* Cv (US) kv x 1,2 APB = All Ports BlockedHerion 97105 In-line SeriesIndirect solenoid actuated soft seal spool valvesFor single and double acting actuators6 mm orifice (ND)3/2, 5/2, 5/3, NC/APB, G , NPT, G , NPTA luminium anodized bodyBrass bodyStainless steel bodyPort sizekgDrawing value (m3/h)*FunctionActuationOther voltages on requestOptions selector 971 XXXX SSoolleennooiiddSee solenoid tablesVVoollttaaggeeSSuubbssttiittuuttee 24 V V V V 97105 In-line SeriesIndirect solenoid actuated soft seal spool valvesFor single and double acting actuators6 mm orifice (ND)3/2, 5/2, 5/3, NC/APB, G , NPT, G , NPTC able gland selecting an intrinsically safe power supply, the permissible maximum values according to the Certificate of Conformity should be taken in account.

6 Thelow effective inductivity and capacity can be selecting an intrinsically safe power supply, the permissible maximum values according to the FM approval should be taken into low effective inductivity and capacity can be ignored.* RW 65 is the solenoid coil resistance at an temperature of +65 C , including internal heat generation, with max. permissble power. 200332408-40 .. +80 -40 .. +70 0,85 131020503912447011-40 .. +80 -40 .. +70 0,85 131020517361788015-40 .. +80 -40 .. +70 0,85 13102052122013146019-40.

7 +80 -40 .. +70 0,85 13102053 ModelkgSolenoiddrawingno.#Circuitdiagram no.#Solenoid actuators for intrinsically-safe circuits, protection class EEx ia IICT5/T6, G, II 2 D, IP66, T90 C,EC type examin. certificate KEMA 03 ATEX 1051 XNominal resistancecoil RN( )Resistancecoil RW60( )*Required voltage atterminal (RW60)Min. requiredswitching current(mA)Temperature rangeAmbient/fluid CT5T6124431506,4-40 .. +650,83 31102040159381937,3-40 .. +650,83 31102041198342408,2-40 .. +650,83 31102042248303019,0-40 .. +650,83 311020433062737110,0-40.

8 +650,83 311020443782545811,5-40 .. +650,83 311020454672356613,0-40 .. +650,83 311020465662168614,4-40 .. +650,83 311020476921983915,9-40 .. +650,83 31102048 ModelkgSolenoiddrawingno.#Circuitdiagram no.#Solenoid actuators with FM approvalIntrinsically safe: IS/I, II, III/1/ABCDEFG/T6 Ta = 65 C; I/0 AEx ia IIC/T6 Ta = 65 C - 0588672/B; EntityNonincendive: NI/I/2/ABCD/T6 Ta = 65 C; S/II,III/2/FG/T6 Ta = 65 C; NEMA Type 4 Nominal resistancecoil RN ( )Resistance coilRW65 ( )*Required voltage atterminal (RW65)Min. requiredswitching current (mA)Temperature rangeAmbient/fluid C# For solenoid dimensional drawings andcircuit diagrams, see page 143# For solenoid dimensional drawings and circuitdiagrams, see page 143 ModelVoltageProtection classTemperature rangeAmbient/fluid CkgSolenoiddrawingno.

9 #Circuitdiagramno.#Power consumption230 V (VA)24 V (W)230 V (mA)24 V (mA)Solenoid actuatorsElectrical connection1,9 2,178 IP00 w/o connector5)-25 .. +60 DIN EN 175 301-803 0,3 10107637)IP65 with connector5)Form A3,6 301 II2 GEEx m II T41)-20 .. +703 m cable0,4 12402988)II2 DIP66 T110 C 4,6 18II2 GEEx m II T41)-20 .. +703 m cable0,4 12702998)II2 DIP66 T110 C0,8 33 II2 GEEx me II T5/T62)-40 .. +80 (T5) M20 X 1,56)0,85 13442008)II2 DIP66 T130 C-40 .. +70 (T6) 1,3 26II2 GEEx me II T4/T62)-40 .. +80 (T4) M20 X 1,56)0,85 13742018)II2 DIP66 T130 C-40.

10 +55 (T6)0,8 33 II2 GEEx me II T5/T63)-40 .. +80 (T5) 1/2 NPT6)0,85 14446008)II2 DEEx md II T5/T63)-40 .. +70 (T6)0,8 33 IP66 T130 CM20 X 1,56)46028) 1,3 26II2 GEEx me II T5/T63)-40 .. +80 (T5) 1/2 NPT 6)0,85 14746018)II2 DEEx md II T5/T63)-40 .. +70 (T6) 1,3 26IP66 T130 CM20 X 1,56)46038)1,4 59 XP (NEMA)4)-20 .. +60 Flying leads 450 mm 0,4 1513720 4, 4X, 6, 6P, 7, 9 3 Standard voltages 24 V , 230 V Other voltages on request. Design acc. to VDE 0580, EN 50014/50028. 100% duty ) Category II 2 GD, EC-Type-Examination-Certificate KEMA 02 ATEX 1347X2) Category II 2 GD, EC-Type-Examination-Certificate KEMA 98 ATEX 4452 X3) Category II 2 GD, EC-Type-Examination-Certificate PTB 02 ATEX 2085 X4) CSA-LR 57643-6, FM approved, for hazardous locations: Div.