Example: confidence

High-Temperature High-Cycle Fatigue (HCF) Standard …

High-Temperature High-Cycle Fatigue (HCF) Standard Solution Designed and validated to speed implementation of High-Temperature materials testing Confidently test to ASTM E466-07, BSI For years, leading researchers have relied Representing decades of MTS materials 3518-3, DIN EN 6072:2011 and ISO on state-of-the-art components, advanced testing expertise and technology leadership, 1099:2006 systems integration expertise and custom the new High-Temperature High-Cycle engineering from MTS to pioneer the Fatigue (HCF) Standard Solution includes Quickly add High-Temperature testing frontiers of High-Temperature materials everything required to test to the ASTM.

High-Temperature High-Cycle Fatigue (HCF) Standard Solution Designed and validated to speed implementation of high-temperature materials testing

Tags:

  High, Solutions, Standards, Temperatures, Cycle, Fatigue, Standard solutions, High temperature high cycle fatigue

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of High-Temperature High-Cycle Fatigue (HCF) Standard …

1 High-Temperature High-Cycle Fatigue (HCF) Standard Solution Designed and validated to speed implementation of High-Temperature materials testing Confidently test to ASTM E466-07, BSI For years, leading researchers have relied Representing decades of MTS materials 3518-3, DIN EN 6072:2011 and ISO on state-of-the-art components, advanced testing expertise and technology leadership, 1099:2006 systems integration expertise and custom the new High-Temperature High-Cycle engineering from MTS to pioneer the Fatigue (HCF) Standard Solution includes Quickly add High-Temperature testing frontiers of High-Temperature materials everything required to test to the ASTM.

2 Capacity with little risk testing. However, configuring and E466-07 Standard , immediately. The Streamline test setup and operations integrating complex High-Temperature solution's configuration is validated by MTS. with easy-to-use HCF subsystem setups can prove a time-consuming, research and development engineers to meet expensive and risky endeavor especially the requirements of ASTM E466-07, using Enhance testing efficiency with for developing labs. Standard cylindrical metallic specimens predefined MTS TestSuite templates (nominal lengths of 100 to 150 mm; reduced To help labs overcome these challenges, Establish a viable, adaptable section diameters of to 10 mm; depending MTS offers a new selection of Standard High-Temperature test platform on grip and furnace configuration) at testing solutions that are engineered to nominal test temperatures ranging from Leverage decades of MTS materials provide an economical, low-risk means 300 to 1000 C.

3 Testing expertise and technology for establishing High-Temperature (up to leadership 1000 C) materials testing capabilities quickly and confidently. Faster Deployment, Lower Risk The MTS High-Temperature HCF Standard Solution is specifically engineered to perform highly accurate and repeatable HCF testing at temperatures from 300 to 1000 C. It comprises the highest-quality components, seamlessly integrated and validated for testing to ASTM E466-07 requirements (with thermal performance to ASTM E606-04e1) so you can commence testing immediately with the highest measure of confidence in the results.

4 This Standard solution includes a compact, easy-to-use HCF subsystem, full-featured MTS TestSuite software with standards -compliant test templates, a high -performance MTS Landmark test system with a robust Model 370 servohydraulic load frame and versatile FlexTest controls, and a clean, quiet SilentFlo hydraulic power unit. The HCF thermal subsystem features a tightly integrated assembly of high -quality MTS. components, including a Model three-zone furnace and Model 646 hydraulic grips with High-Temperature furnace extensions. This subsystem can be purchased independent of a load frame system.

5 Installation can be performed by MTS Technicians or can be self-installed, using our new video manuals. A Model 370 Load Frame C Model 661 Force Transducer of results. The ADV HCF module packages the test and report templates high -performance MTS 370 load This high -output, fully Fatigue -rated and calculations required to perform frames feature extremely stiff and load cell features noise-reducing wiring, HCF testing up to 60 Hz in load control. lightweight crossheads with high temperature compensation, low hysteresis New predefined test templates provide natural frequencies, and precision- and long-term stability.

6 Automated control of temperature machined columns for consistently ramping (minimal overshoot) and tight alignment. Fatigue -rated MTS D MTS TestSuite MP Elite Software improved gradient accuracy. actuators and smooth-ramping hydraulic service manifolds deliver MTS TestSuite MP Elite Software makes superior reliability and precise control. it easy for researchers to create and run E FlexTest Controller tests, as well as report and conduct analysis Scalable and easy-to-use FlexTest B MTS Alignment Solution controllers provide the high -speed closed-loop control, data acquisition, This compact, easy-to-use kit includes a function generation and transducer precision fixture, strain-gaged specimens, conditioning needed to perform a full and the software, data acquisition and spectrum of materials testing with conditioning required to achieve efficiency and confidence.

7 Proper load frame alignment and ensure compliance with numerous industry standards . F SilentFlo Hydraulic Power Unit B Trouble-free SilentFlo hydraulic power units (HPUs) are quiet enough C. to be located directly in the lab. They are designed to handle continuous-duty servohydraulic applications, so they F perform reliably, year after year. D. E. A. High-Temperature HCF Thermal Subsystem 1 Model Furnace 3 Model 646 Hydraulic Grips with Three independently controlled Furnace Extensions THERMAL PERFORMANCE. temperature zones Hot grip with maximum temperature Nominal test temperature between Capable of achieving temperatures rating of 1000 C (1800 F), minimum 300 C and 1000 C (cylindrical specimen).

8 Up to 1400 C (2550 F)(non-testing of 20 C (70 F) temperatures below 300 C are achievable environment) Dynamic operating rating of 66 kN up with lower performance Capable of achieving 1000 C (1800 F) to 700 C, 9 kN up to 1000 C. in validated testing conditions with Buttonhead and threaded specimen Gradient of 1% nominal test temperature Standard solution adapters across reduced section Durable, low-maintenance furnace Improved cooling circuit enhances Gage length temperature changes no more insulation with pre-cut design reduces equipment safety than 1% nominal temperature during heat loss Compact, economical grip supply multiple-day period Clamshell design streamlines test (mounted to load frame).

9 Setup, furnace alignment, and 1000 C test temperature achieved in 30. specimen changeover 4 Thermal Gradient Verification Kit minutes with automated ramps to minimize Stainless steel shell Type K thermocouple kit overshoot Thermocoupled specimen 2 Model 409 Temperature Controller Thermal Data Acquisition (links with PC. Features individual controls and to analyze specimen thermal gradient). displays for three heating zones 1. 4. 3. 2. A Choice of Installation Support Levels for the High-Temperature HCF Thermal Subsystem Meaningful High-Temperature testing requires confidence in the integrity of the test setup.

10 To help labs pursue testing programs with a high degree of certainty, MTS offers three levels of installation support with the High-Temperature HCF thermal subsystem. Level 1 Installation Support Level 2 Installation Support Level 3 Installation Support MTS will install and integrate our Standard Features the added benefit of MTS Features the added benefit of MTS. Solution in your lab, and conduct a technicians validating the thermal technicians validating the thermal functional check of the integrated thermal performance of this Standard solution performance of your customized solution subsystem to confirm its operation.


Related search queries