Example: bankruptcy

HiTrap HIC columns - S. Mansy

Page 1 Thursday, March 19, 2009 3:23 PM. GE Healthcare Instructions 11-0034-52 AF HiTrap HIC columns HiTrap HIC columns HiTrap Phenyl FF (high sub), 1 ml and 5 ml HiTrap Phenyl FF (low sub), 1 ml and 5 ml HiTrap Phenyl HP, 1 ml and 5 ml HiTrap Butyl FF, 1 ml and 5 ml HiTrap Butyl-S FF, 1 ml and 5 ml HiTrap Butyl HP, 1 ml and 5 ml HiTrap Octyl FF, 1 ml and 5 ml HiTrap HIC Selection Kit HiTrapTM Phenyl FF (high sub), HiTrap Phenyl FF (low sub), HiTrap Phenyl HP, HiTrap Butyl FF, HiTrap Butyl-S FF, HiTrap Butyl HP, and HiTrap Octyl FF are prepacked 1 ml and 5 ml, ready to use hydrophobic interaction chromatography (HIC) columns . The column together with modern chromatography media, provides fast, reproducible and easy separation in a convenient format. HiTrap HIC Selection Kit consists of seven Hydrophobic Interaction Chromatography media (HIC) with different hydrophobic characteristics.

11-0034-52 AF 7 Butyl-S Sepharose 6 Fast Flow is based on a 90 µm matrix. The main differences between Butyl-S Sepharose 6 Fast Flow and Butyl Sepharose 4 Fast Flow lie in the length of their spacer arms, the

Tags:

  Between, Differences, Columns, Differences between, Hitrap hic columns, Hitrap

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of HiTrap HIC columns - S. Mansy

1 Page 1 Thursday, March 19, 2009 3:23 PM. GE Healthcare Instructions 11-0034-52 AF HiTrap HIC columns HiTrap HIC columns HiTrap Phenyl FF (high sub), 1 ml and 5 ml HiTrap Phenyl FF (low sub), 1 ml and 5 ml HiTrap Phenyl HP, 1 ml and 5 ml HiTrap Butyl FF, 1 ml and 5 ml HiTrap Butyl-S FF, 1 ml and 5 ml HiTrap Butyl HP, 1 ml and 5 ml HiTrap Octyl FF, 1 ml and 5 ml HiTrap HIC Selection Kit HiTrapTM Phenyl FF (high sub), HiTrap Phenyl FF (low sub), HiTrap Phenyl HP, HiTrap Butyl FF, HiTrap Butyl-S FF, HiTrap Butyl HP, and HiTrap Octyl FF are prepacked 1 ml and 5 ml, ready to use hydrophobic interaction chromatography (HIC) columns . The column together with modern chromatography media, provides fast, reproducible and easy separation in a convenient format. HiTrap HIC Selection Kit consists of seven Hydrophobic Interaction Chromatography media (HIC) with different hydrophobic characteristics.

2 The kit provides the possibility to screen for the most appropriate HIC. medium for specific applications. The recommended test procedures help optimize salt concentration, sample loading, resolution and other chromatographic parameters. The seven different media are prepacked in ready to use 1 ml HiTrap columns . Separations are easily performed with a syringe, a pump or a chromatography system such as KTATM design. Page 2 Thursday, March 19, 2009 3:23 PM. Code No. Product No. supplied 17-1355-01 HiTrap Phenyl FF (high sub) 5 1 ml 17-5193-01 HiTrap Phenyl FF (high sub) 5 5 ml 17-1353-01 HiTrap Phenyl FF (low sub) 5 1 ml 17-5194-01 HiTrap Phenyl FF (low sub) 5 5 ml 17-1351-01 HiTrap Phenyl HP 5 1 ml 17-5195-01 HiTrap Phenyl HP 5 5 ml 17-1357-01 HiTrap Butyl FF 5 1 ml 17-5197-01 HiTrap Butyl FF 5 5 ml 17-0978-13 HiTrap Butyl-S FF 5 1 ml 17-0978-14 HiTrap Butyl-S FF 5 5 ml 28-4110-01 HiTrap Butyl HP 5 1 ml 28-4110-05 HiTrap Butyl HP 5 5 ml 17-1359-01 HiTrap Octyl FF 5 1 ml 17-5196-01 HiTrap Octyl FF 5 5 ml Connector kit Connectors Usage No.

3 Supplied supplied 1/16" male/ Connection of syringe to top of 1. luer female HiTrap column Tubing connector Connection of tubing ( Peristaltic 1. flangeless/ Pump P1) to bottom of HiTrap M6 female column1. Tubing connector Connection of tubing ( Peristaltic 1. flangeless/M6 male Pump P1) to top of HiTrap column2. Union 1/16" Connection to original FPLCTM 1. female/M6 male System through bottom of HiTrap column Union M6 female/ Connection to original FPLC System 1. 1/16" male through top of HiTrap column Stop plug female, Sealing bottom of HiTrap column 2, 5 or 7. 1/16". 1 Union 1/16" female/M6 male is also needed. 2 Union M6 female/1/16" male is also needed. 2 11-0034-52 AF. Page 3 Thursday, March 19, 2009 3:23 PM. Code No. Product No. supplied 28-4110-07 HiTrap HIC Selection Kit Including: HiTrap Phenyl FF (high sub) 1 1 ml HiTrap Phenyl FF (low sub) 1 1 ml HiTrap Phenyl HP 1 1 ml HiTrap Butyl FF 1 1 ml HiTrap Butyl-S FF 1 1 ml HiTrap Butyl HP 1 1 ml HiTrap Octyl FF 1 1 ml Connector kit Connectors Usage No.

4 Supplied supplied 1/16" male/ Connection of syringe to top of 1. luer female HiTrap column Tubing connector Connection of tubing ( Peristaltic 1. flangeless/ Pump P1) to bottom of HiTrap M6 female column1. Tubing connector Connection of tubing ( Peristaltic 1. flangeless/M6 male Pump P1) to top of HiTrap column2. Union 1/16" Connection to original FPLC System 1. female/M6 male through bottom of HiTrap column Union M6 female/ Connection to original FPLC System 1. 1/16" male through top of HiTrap column Stop plug female, Sealing bottom of HiTrap column 7. 1/16". 1 Union 1/16" female/M6 male is also needed. 2 Union M6 female/1/16" male is also needed. 11-0034-52 AF 3. Page 4 Thursday, March 19, 2009 3:23 PM. Table of contents 1. Media 5. 2. Column .. 8. 3. Hydrophobic Interaction 9. 4. 19. 5. Determination of binding capacity .. 22. 6. Cleaning and regeneration .. 23. 7. Scaling 23. 8.

5 Storage .. 23. 9. Intended use .. 23. 10. Ordering information .. 24. 4 11-0034-52 AF. Page 5 Thursday, March 19, 2009 3:23 PM. 1 Media properties The HIC media are based on the highly cross-linked beaded agarose matrices, SepharoseTM Fast Flow and Sepharose High Performance. The media have excellent flow properties with high physical and chemical stabilities. All Sepharose matrices show virtually no non- specific adsorption and are resistant to microbial degradation due to the presence of the unusual sugar, 3,6-anhydro-L-galactose. The hydrophobic ligands are coupled to the monosaccharide units via glycidylethers. The resulting ether bonds are both stable and uncharged. Characteristics of the different HiTrap HIC media are listed in Table 1 and their chemical stability is described on page 7. Phenyl Sepharose High Performance is based on a 34 m matrix and is ideal for laboratory and intermediate process scale separations and for final step purifications where high resolution is needed.

6 The degree of substitution gives Phenyl Sepharose High Performance a selectivity similar to that of Phenyl Sepharose 6 Fast Flow (low sub). Butyl Sepharose High Performance is based on a 34 m matrix. The small beads with high rigidity gives high resolution at high flow rate, and make the product excellent for polishing steps. Even though the ligand concentration is higher than for the other Butyl media, it shows a similar selectivity as for those products for the test proteins used in the functional test. Phenyl Sepharose 6 Fast Flow (low sub) and Phenyl Sepharose 6 Fast Flow (high sub) are based on a 90 m matrix. They are ideal for initial and intermediate step purifications requiring a matrix with medium to high hydrophobicity. The availability of two degrees of substitution grades increases the possibility of finding the best selectivity and capacity for a given application. Butyl Sepharose 4 Fast Flow is based on a 90 m matrix.

7 It is intended for initial and intermediate step purifications requiring a matrix with low to medium hydrophobicity. Butyl Sepharose 4 Fast Flow often works efficiently with rather low salt concentrations. The mechanism of adsorption and desorption onto the butyl ligand is different from that onto the phenyl ligand, giving a different selectivity. 11-0034-52 AF 5. 6. Media Hydrophobic Ligand Average pH stability, pH stability, ligand density particle size short term long term Phenyl Sepharose Phenyl 25 mol/ml 34 m 2 to 14 3 to 13. High Performance medium Phenyl Sepharose Phenyl 25 mol/ml 90 m 2 to 14 3 to 13. 6 Fast Flow (low sub) medium Phenyl Sepharose Phenyl 40 mol/ml 90 m 2 to 14 3 to 13. 6 Fast Flow (high sub) medium Butyl Sepharose Butyl 50 mol/ml 34 m 2 to 14 3 to 13. High Performance medium Butyl Sepharose Butyl 40 mol/ml 90 m 2 to 14 3 to 13. 4 Fast Flow medium Table 1. HiTrap HIC media characteristics Butyl-S Sepharose Butyl-S 10 mol/ml 90 m 2 to 14 3 to 13.

8 6 Fast Flow medium Octyl Sepharose Octyl 5 mol/ml 90 m 2 to 14 3 to 13. 4 Fast Flow medium Page 6 Thursday, March 19, 2009 3:23 PM. Please note the following: pH stability, long term: pH interval where the medium can be operated without significant change in function. pH stability, short term: pH interval to which the medium can be subjected for cleaning- or sanitization-in-place (accumulated 90 100 hours at room temperature) without significant change in function. Matrices: All media are based on 6% crosslinked agarose with spherical beads except for the two Sepharose 4 Fast Flow with the Butyl and Octyl ligands, which are based on 4% crosslinked agarose, spherical beads. Storage: M NaOH or 20% ethanol. 11-0034-52 AF. Page 7 Thursday, March 19, 2009 3:23 PM. Butyl-S Sepharose 6 Fast Flow is based on a 90 m matrix. The main differences between Butyl-S Sepharose 6 Fast Flow and Butyl Sepharose 4 Fast Flow lie in the length of their spacer arms, the concentration of the immobilized ligands, and the type of connector atom (O-ether or S-ether) linking each ligand to the Sepharose base matrix.

9 Butyl-S Sepharose 6 Fast Flow contains a sulfur atom as a linker between the spacer arm and the butyl ligand. It is the least hydrophobic medium in the GE Healthcare portfolio and is intended for purification or removal of strongly hydrophobic biomolecules at low salt concentrations, with high recovery and low risk of denaturation. Octyl Sepharose 4 Fast Flow is based on a 90 m matrix. It has a different hydrophobic character from the phenyl and butyl ligands and is an important complement to the other hydrophobic matrices. Chemical stability Good chemical stability allows the use of the prepacked columns with most commonly used buffers and organic solvents, like for example 1 M NaOH, 70% ethanol, 30% isopropanol, 6 M GuHCl and 8 M urea. The compatibility with other solvents have been verified by conducting stability test for some of the media with 1 M acetic acid, 3 M (NH4) SO4 and 1 M HCl.

10 11-0034-52 AF 7. Page 8 Thursday, March 19, 2009 3:23 PM. 2 Column The column is made of polypropylene, which is biocompatible and noninteractive with biomolecules. The top and bottom frits are manufactured from porous polyethylene. It is delivered with a stopper on the inlet and a snap-off end on the outlet. The separation can be easily achieved using a syringe together with the supplied luer connector, a peristaltic pump, or in a chromatography system such as KTA design. Note: To prevent leakage it is essential to ensure that the connector is tight. Note: The column cannot be opened or refilled. Characteristics of HiTrap column are listed in Table 2. Table 2. Characteristics of HiTrap column. Column volume 1 ml or 5 ml Column dimension cm (1 ml) or cm (5 ml). Recommended flow rate HiTrap 1 ml: 1 ml/min HiTrap 5 ml: 5 ml/min Maximum flow rate1 HiTrap 1 ml: 4 ml/min HiTrap 5 ml: 20 ml/min Maximum back pressure MPa, 3 bar 1 Room temperature, aqueous buffers.


Related search queries