Example: dental hygienist

HMX Network Audio System SYSTEMS - EVAX

Distributed Panel (HMX-DP) 4 Output Zones (may be configured for 8) Dual Channel Audio Interface Dual/Single Channel Amplification Amplifier Options: 25 / 50 / 100W Dual Channel 25 / 50 / 100 / 200W Single Channel Optional Integrated Fire Phone 4 Circuits expandable to 8, 12 or 16 Fiber Optic Network capable Maximum System Configuration Up to 256 Distributed Panels (HMX-DP)EVAX HMX-DPDistributed PanelTB1TB3TB212345678123456781234567891 011 MESSAGEGAINMICGAINFAULTNORMALALARMYELGRN REDJ2123J1P2S1SN1TB1TB3TB212345678123456 781234567891011 MESSAGEGAINMICGAINFAULTNORMALALARMYELGRN REDJ2123J1P2S1SN1 DCCTB1TB2P1P2P3P4J1123 DCCMBRTB2TB3TB4TB5TB6TB7TB81 2 3 4TB11 2 3 41 2 3 41 2 3 41 2 3 41 2 3 41 2 3 41 2 3 41 2 3 4 AMIMBKEVX-25 EEVX-25E18 B 4 A PAGING CONTROLSYSTEMRESETPAGEALL-CALLFAULTSILEN CEEVAX HMX-MPMaster PanelMaster Panel (HMX-MP) Master Mic Control 16 Switch

Specifications are subject to change without notice. Specifications are provided for information only and no responsibility is assumed by Evax Systems, Inc. for their use.

Tags:

  System, Audio

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of HMX Network Audio System SYSTEMS - EVAX

1 Distributed Panel (HMX-DP) 4 Output Zones (may be configured for 8) Dual Channel Audio Interface Dual/Single Channel Amplification Amplifier Options: 25 / 50 / 100W Dual Channel 25 / 50 / 100 / 200W Single Channel Optional Integrated Fire Phone 4 Circuits expandable to 8, 12 or 16 Fiber Optic Network capable Maximum System Configuration Up to 256 Distributed Panels (HMX-DP)EVAX HMX-DPDistributed PanelTB1TB3TB212345678123456781234567891 011 MESSAGEGAINMICGAINFAULTNORMALALARMYELGRN REDJ2123J1P2S1SN1TB1TB3TB212345678123456 781234567891011 MESSAGEGAINMICGAINFAULTNORMALALARMYELGRN REDJ2123J1P2S1SN1 DCCTB1TB2P1P2P3P4J1123 DCCMBRTB2TB3TB4TB5TB6TB7TB81 2 3 4TB11 2 3 41 2 3 41 2 3 41 2 3 41 2 3 41 2 3 41 2 3 41 2 3 4 AMIMBKEVX-25 EEVX-25E18 B 4 A PAGING CONTROLSYSTEMRESETPAGEALL-CALLFAULTSILEN CEEVAX HMX-MPMaster PanelMaster Panel (HMX-MP)

2 Master Mic Control 16 Switch Control points Dual Channel DMR High Speed communication loop Optional Integrated Master Fire Phone Fiber Optic Network capable Maximum System Configuration Up to 1000 switch/input pointsHMX Network Audio SystemSystem Configuration:LISTED#S5661277-96-E6911-1 446:103 SYSTEMSSOUND SOLUTIONS20 McDermott Road Branford, CT 06405 PH: 203-315-5116 FAX: 315-5118 are subject to change without notice. Specificationsare provided for information only and no responsibility is assumedby Evax SYSTEMS , Inc. for their Panel Configurations:HMX-DPS25 Distributed Panel, Single Channel, 25 WHMX-DPS50 Distributed Panel, Single Channel, 50 WHMX-DPS100 Distributed Panel, Single Channel, 100 WHMX-DPS25/PDistributed Panel, Single Channel, 25W, Fire PhoneHMX-DPS50/PDistributed Panel, Single Channel, 50W, Fire PhoneHMX-DPS100/PDistributed Panel, Single Channel, 100W, Fire PhoneHMX-DP25 Distributed Panel, Dual Channel, 25 WHMX-DP50 Distributed Panel, Dual Channel, 50 WHMX-DP100 Distributed Panel, Dual Channel, 100W, Single Channel 200W HMX-DP25/PDistributed Panel, Dual Channel, 25W, Fire PhoneHMX-DP50/PDistributed Panel, Dual Channel, 50W.

3 Fire PhoneHMX-DP100/PDistributed Panel, Dual Channel, 100W, Fire Phone, Single Channel 200W Panel Options: Cards may be added as job requirements demandMX-MBK Motherboard Relay CardExpands MBR output 8 Class B or 4 Class A circuitsMX-FPI Fire Phone Interface CardIncluded in /P panels, up to 3 additional cards may be addedMX-FPO Fire Phone Output CardUsed with additional MX-FPIs for terminationMX-AMI Audio Module Interface CardIncluded with basic panel, additional cards give the ability to control multiple modules Technical Characteristics:Primary Power: 120 VAC24 VDC Battery Power Backbox Dim: x 27 x 4 whdColor: Charcoal Greystd Redoptional Electrical Ratings: All Circuits @ 24 VDC.

4 Communications Bus: RS-485 Standard, 1M Baud data rate, Low Capacitance : 5V peak-to-peak max. Frequency: : 50mA max. Impedance: 120 Ohms (max. imp. between panels) Battery Charging: Maximum charging current from EVX-25/50 is 800mA. Maximum battery size is 17 AhEVX-100 is 1A. Maximum battery size is 24 AhDCCMBRAMIFPI 55 mA10 mA10 mA13 mA Distributed Panel55 mA55 mA10 mA13 mA Standby Alarm Master Panel Configurations:HMX-MP16 Master Panel, 16 Switch ControlHMX-MP32 Master Panel, 32 Switch ControlHMX-MP48 Master Panel, 48 Switch ControlHMX-MP64 Master Panel, 64 Switch ControlHMX-MP80 Master Panel, 80 Switch ControlHMX-MP96 Master Panel, 96 Switch ControlHMX-MP16/PMaster Panel, 16 Switch Control, Master Fire PhoneHMX-MP32/PMaster Panel, 32 Switch Control, Master Fire PhoneHMX-MP64/PMaster Panel, 64 Switch Control, Master Fire PhoneHMX-MP80/PMaster Panel, 80 Switch Control, Master Fire PhoneHMX-MP96/PMaster Panel, 96 Switch Control, Master Fire PhonePanel Options.

5 Cards may be added as job requirements demandMX-MFP Master Fire PhoneEnables System to incorporate 2 way communication. Included with /P Switch Scan CardIncluded in basic panels, up to 7 additional cards may be Switch LED Card16 Switch LED Bank, up to 8 per Audio Module Interface CardOne included with basic panel, additional cards give 16 control inputs each. Maximum of mA30 mA10 mA25 mA 6 mA45 mA20 mAMaster PanelDCCASCMFPSSCSLCMMCIOI80 mA30 mA10 mA25 mA 6 mA45 mA20 mAStandbyAlarm SYSTEMSSOUND SOLUTIONS20 McDermott Road Branford, CT 06405 PH: 203-315-5116 FAX: 315-5118