Example: stock market

HMX Network Audio System SYSTEMS - EVAX

Distributed Panel (HMX-DP) 4 Output Zones (may be configured for 8) Dual Channel Audio Interface Dual/Single Channel Amplification Amplifier Options: 25 / 50 / 100W Dual Channel 25 / 50 / 100 / 200W Single Channel Optional Integrated Fire Phone 4 Circuits expandable to 8, 12 or 16 Fiber Optic Network capable Maximum System Configuration Up to 256 Distributed Panels (HMX-DP) evax HMX-DPDistributed PanelTB1TB3TB212345678123456781234567891 011 MESSAGEGAINMICGAINFAULTNORMALALARMYELGRN REDJ2123J1P2S1SN1TB1TB3TB212345678123456 781234567891011 MESSAGEGAINMICGAINFAULTNORMALALARMYELGRN REDJ2123J1P2S1SN1 DCCTB1TB2P1P2P3P4J1123 DCCMBRTB2TB3TB4TB5TB6TB7TB81 2 3 4TB11 2 3 41 2 3 41 2 3 41 2 3 41 2 3 41 2 3 41 2 3 41 2 3 4 AMIMBKEVX-25 EEVX-25E18 B 4 A PAGING CONTROLSYSTEMRESETPAGEALL-CALLFAULTSILEN CEEVAX HMX-MPMaster PanelMaster Panel (HMX-MP) Master Mic Control 16 Switch Control points Dual Channel DMR High Speed communication loop Optional Integrated Master

Distributed Panel (HMX-DP) 4 Output Zones (may be configured for 8) Dual Channel Audio Interface Dual/Single Channel Amplification High Speed communication loop

Tags:

  Network, System, Audio, Evax, Hmx network audio system systems evax

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of HMX Network Audio System SYSTEMS - EVAX

1 Distributed Panel (HMX-DP) 4 Output Zones (may be configured for 8) Dual Channel Audio Interface Dual/Single Channel Amplification Amplifier Options: 25 / 50 / 100W Dual Channel 25 / 50 / 100 / 200W Single Channel Optional Integrated Fire Phone 4 Circuits expandable to 8, 12 or 16 Fiber Optic Network capable Maximum System Configuration Up to 256 Distributed Panels (HMX-DP) evax HMX-DPDistributed PanelTB1TB3TB212345678123456781234567891 011 MESSAGEGAINMICGAINFAULTNORMALALARMYELGRN REDJ2123J1P2S1SN1TB1TB3TB212345678123456 781234567891011 MESSAGEGAINMICGAINFAULTNORMALALARMYELGRN REDJ2123J1P2S1SN1 DCCTB1TB2P1P2P3P4J1123 DCCMBRTB2TB3TB4TB5TB6TB7TB81 2 3 4TB11 2 3 41 2 3 41 2 3 41 2 3 41 2 3 41 2 3 41 2 3 41 2 3 4 AMIMBKEVX-25 EEVX-25E18 B 4 A PAGING CONTROLSYSTEMRESETPAGEALL-CALLFAULTSILEN CEEVAX HMX-MPMaster PanelMaster Panel (HMX-MP)

2 Master Mic Control 16 Switch Control points Dual Channel DMR High Speed communication loop Optional Integrated Master Fire Phone Fiber Optic Network capable Maximum System Configuration Up to 1000 switch/input pointsHMX Network Audio SystemSystem Configuration:LISTED#S5661277-96-E6911-1 446:103 SYSTEMSSOUND SOLUTIONS20 McDermott Road Branford, CT 06405 PH: 203-315-5116 FAX: 315-5118 are subject to change without notice. Specificationsare provided for information only and no responsibility is assumedby evax SYSTEMS , Inc. for their Panel Configurations:HMX-DPS25 Distributed Panel, Single Channel, 25 WHMX-DPS50 Distributed Panel, Single Channel, 50 WHMX-DPS100 Distributed Panel, Single Channel, 100 WHMX-DPS25/PDistributed Panel, Single Channel, 25W, Fire PhoneHMX-DPS50/PDistributed Panel, Single Channel, 50W, Fire PhoneHMX-DPS100/PDistributed Panel, Single Channel, 100W, Fire PhoneHMX-DP25 Distributed Panel, Dual Channel, 25 WHMX-DP50 Distributed Panel, Dual Channel, 50 WHMX-DP100 Distributed Panel, Dual Channel, 100W, Single Channel 200W HMX-DP25/PDistributed Panel, Dual Channel, 25W, Fire PhoneHMX-DP50/PDistributed Panel, Dual Channel, 50W, Fire PhoneHMX-DP100/PDistributed Panel, Dual Channel, 100W, Fire Phone.

3 Single Channel 200W Panel Options: Cards may be added as job requirements demandMX-MBK Motherboard Relay CardExpands MBR output 8 Class B or 4 Class A circuitsMX-FPI Fire Phone Interface CardIncluded in /P panels, up to 3 additional cards may be addedMX-FPO Fire Phone Output CardUsed with additional MX-FPIs for terminationMX-AMI Audio Module Interface CardIncluded with basic panel, additional cards give the ability to control multiple modules Technical Characteristics:Primary Power: 120 VAC24 VDC Battery Power Backbox Dim: x 27 x 4 whdColor: Charcoal Greystd Redoptional Electrical Ratings: All Circuits @ 24 VDC. Communications Bus: RS-485 Standard, 1M Baud data rate, Low Capacitance : 5V peak-to-peak max.

4 Frequency: : 50mA max. Impedance: 120 Ohms (max. imp. between panels) Battery Charging: Maximum charging current from EVX-25/50 is 800mA. Maximum battery size is 17 AhEVX-100 is 1A. Maximum battery size is 24 AhDCCMBRAMIFPI 55 mA10 mA10 mA13 mA Distributed Panel55 mA55 mA10 mA13 mA Standby Alarm Master Panel Configurations:HMX-MP16 Master Panel, 16 Switch ControlHMX-MP32 Master Panel, 32 Switch ControlHMX-MP48 Master Panel, 48 Switch ControlHMX-MP64 Master Panel, 64 Switch ControlHMX-MP80 Master Panel, 80 Switch ControlHMX-MP96 Master Panel, 96 Switch ControlHMX-MP16/PMaster Panel, 16 Switch Control, Master Fire PhoneHMX-MP32/PMaster Panel, 32 Switch Control, Master Fire PhoneHMX-MP64/PMaster Panel, 64 Switch Control, Master Fire PhoneHMX-MP80/PMaster Panel, 80 Switch Control, Master Fire PhoneHMX-MP96/PMaster Panel, 96 Switch Control, Master Fire PhonePanel Options: Cards may be added as job requirements demandMX-MFP Master Fire PhoneEnables System to incorporate 2 way communication.

5 Included with /P Switch Scan CardIncluded in basic panels, up to 7 additional cards may be Switch LED Card16 Switch LED Bank, up to 8 per Audio Module Interface CardOne included with basic panel, additional cards give 16 control inputs each. Maximum of mA30 mA10 mA25 mA 6 mA45 mA20 mAMaster PanelDCCASCMFPSSCSLCMMCIOI80 mA30 mA10 mA25 mA 6 mA45 mA20 mAStandbyAlarm SYSTEMSSOUND SOLUTIONS20 McDermott Road Branford, CT 06405 PH: 203-315-5116 FAX: 315-5118