Honeywell Controls Cross Reference

PARTSQuICk REfEREnCEhoneywell Cross referenCeHONEYWELL # Cross REFERENCEUNIVERSAL IGNITION MODULES8910U1000 Robertshaw: HS780-17NL 104A, 306A, 308A, HS780-17NR 104A, 306A, 308A, HS780-34NL 108A, 304A, 306A, 308A, 312A, HS780-34NR 104A, 306A, 308A, 312A, HS780-34PL 308A White-Rodgers: 50E47 1-79, 101-179, 201-279, 301-379, 5047F 1-79, 101-179, 201-279, 301-379 S8610U3009 Johnson Controls : CSA42, 43, 44, 45, 46, 48, 49, G60, G65, G67, G770 Series Robertshaw: 780-701, 710-713, 715, 735-737, SP710, SP715, SP720, SP730, SP735, SP750 Series White-Rodgers: 50D50-843unIVERSAL IGnITIOn MODuLES8910u1000 Provide electronic control of direct hot surface ignition systems used on gas fired furnaces, boilers, and other heating appliancesSpecifications Ignition System Type: Direct Hot Surface Ignition Typical Gas Control: VR8205, VR8305 Type of Gas: Natural or LP Flame Sense: Single Rod or Two Rods Ignition Source: Line Voltage (120 VAC) Hot Surface Element (Norton Model 201 or 270) PrePurge: 32 seconds Ignition Trials To Lockout: 1 or 3 Model or Two Rod Intermittent Pilot Control with continuous retry

HONEYWELL # CROSS REFERENCE UNIVERSAL GAS VALVE VR8300A3500 Robertshaw: 720-406 (7200ER) White-Rodgers: 36C01-405 VR8345M4302 White-Rodgers: 36E36-304, 36C68-423 SMART VALVE VR8300A3500 24 Vac Dual Standing Pilot Gas Valve with 1/2" x 3/4" inlet/outlet, standard opening and 3.5" wc pressure regulator

Tags:

  Cross, Reference, Valves, Cross reference

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Honeywell Controls Cross Reference

1 PARTSQuICk REfEREnCEhoneywell Cross referenCeHONEYWELL # Cross REFERENCEUNIVERSAL IGNITION MODULES8910U1000 Robertshaw: HS780-17NL 104A, 306A, 308A, HS780-17NR 104A, 306A, 308A, HS780-34NL 108A, 304A, 306A, 308A, 312A, HS780-34NR 104A, 306A, 308A, 312A, HS780-34PL 308A White-Rodgers: 50E47 1-79, 101-179, 201-279, 301-379, 5047F 1-79, 101-179, 201-279, 301-379 S8610U3009 Johnson Controls : CSA42, 43, 44, 45, 46, 48, 49, G60, G65, G67, G770 Series Robertshaw: 780-701, 710-713, 715, 735-737, SP710, SP715, SP720, SP730, SP735, SP750 Series White-Rodgers: 50D50-843unIVERSAL IGnITIOn MODuLES8910u1000 Provide electronic control of direct hot surface ignition systems used on gas fired furnaces, boilers, and other heating appliancesSpecifications Ignition System Type: Direct Hot Surface Ignition Typical Gas Control: VR8205, VR8305 Type of Gas: Natural or LP Flame Sense: Single Rod or Two Rods Ignition Source: Line Voltage (120 VAC) Hot Surface Element (Norton Model 201 or 270) PrePurge: 32 seconds Ignition Trials To Lockout: 1 or 3 Model or Two Rod Intermittent Pilot Control with continuous retry trial time with configurable lockout timing of 15 or 90 seconds and configurable prepurge of 30 seconds or no prepurgeSpecifications Ignition System Type.

2 Intermittent Pilot Typical Gas Control: VR8204, VR8304 Type of Gas: Natural or LP Flame Sense: Single Rod or Two Rods Ignition Source: Internal high voltage spark generator PrePurge: Configurable to 30 seconds or no prepurge Ignition Trials To Lockout: Continuous retry Model hOT SuRfACE IGnITIOnunIVERSAL ELECTROnIC fAn TIMERST9120u1011 Application: Integrates control of combustion blower and circulating fan operations for a gas warm air applianceSpecifications Electrical Ratings: 18 to 30 Vac Heat Fan On Delay: Adj. 30, 60 sec (set at 30 sec) Heat Fan Off Delay: Adj. 60, 120, 150, 180 sec (set at 120 sec) Cool Fan On Delay: Adj. 4, 30 sec (set at 4 sec) Cool Fan Off Delay: Adj. 30, 60 sec (set at 30 sec)Replaces all ST9101's, all ST9120's, all ST9141's, and all ST9160'sModel Hot Surface Ignition Integrated Furnace Control.

3 Controls a standard induction-type circulating fan motor. Universal single stage heating & coolingSpecifications Line Voltage: 120 Vac (97-132 Vac) Low Voltage: 24V (18-30 Vac) Operating Temperature: -40 F to +175 F PrePurge: 30 seconds Trial For Ignition: 4, 6, or 8 seconds PostPurge: 15 seconds Interpurge: 60 seconds Ignition Trials: Three, two tries if flame is not sensed Heat On Fan Delay: 30 or 60 seconds Heat Off Fan Delay: 60, 90, 120, or 180 Seconds Cool Fan On Delay: 5 seconds Cool Fan Off Delay: 0 or 60 seconds Model VALVESV9520h85131/2" NPT x 1/2" NPT Direct Hot Surface Ignition SmartValve Control with fast-slow opening and " wc pressure regulator settingSpecifications Flame Sense: Two Rod Type of Gas: Natural Ignition System Type.

4 Direct Hot Surface Ignition Ignition Trials To Lockout: 4 trials PrePurge: 15 seconds Body Pattern: Straight-through Opening Characteristics (standard, step): Fast-Slow Opening Ignition Trial Time (sec): 7 sec Model " NPT x 1/2" NPT Intermittent Hot Surface Pilot Ignition SmartValve Control with standard opening and " wc pressure regulator settingSpecifications Flame Sense: Electrode Type of Gas: Natural Ignition System Type: Intermittent Hot Surface Pilot Ignition Ignition Sequence: Intermittent Pilot Ignition Source: Pilot Ignition Trials To Lockout: Continuous retry PrePurge: None Body Pattern: Straight-through Opening Characteristics (standard, step): Standard Opening Ignition Trial Time (sec): 90 sec Model Controls88 Prices & Specifications subject to change without PARTSQuICk REfEREnCEhoneywell Cross referenCeHONEYWELL # Cross REFERENCEUNIVERSAL GAS VALVEVR8300A3500 Robertshaw: 720-406 (7200ER) White-Rodgers: 36C01-405 VR8345M4302 White-Rodgers: 36E36-304, 36C68-423 SMART VALVEVR8300A350024 Vac Dual Standing Pilot Gas Valve with 1/2" x 3/4" inlet/outlet, standard opening and " wc pressure regulator settingSpecifications Type: Single Stage Ignition Type: Standing Pilot Type of Gas: Natural Body Pattern: Straight through with integral tapping; with flange Opening Characteristics (standard, step): Standard Capacity @ 1 in.

5 : 190,000 BTU/hr; 30,000 BTU/hr minimum Pressure Ratings (psi): 1/2 psi Pilot Gas Outlet: Compression fitting for 1/4" OD tubing Pressure Tapping: 1/8" NPT with plug Temperature Range: 0 to 175 FL6006A1145 Circulator Control, High Limit or Low Limit Aquastat Controller with 100 F to 240 F operating temperature and 5 F to 30 F adj. DifferentialModel Vac Dual Direct Ignition/Intermittent pilot Gas Valve with 3/4" x 3/4" inlet/outlet, standard opening and " wc pressure regulator settingSpecifications Type: Single Stage Ignition Type: Direct Ignition / Intermittent Pilot Type of Gas: Natural Body Pattern: Straight-through Opening Characteristics (standard, step): Standard Capacity @ 1 in. : 300,000 BTU/hr; 30,000 BTU/hr minimum Pressure Ratings (psi): 1/2 psi Pressure Tapping: 1/8" NPT with plug Temperature Range: -40 to 175 FModel Bulb Size: 3/8" x 2-7/8" copper Capillary Length: 3" Switching Action: SPDT Maximum Ambient Temperature (F): 150 F Case Dimensions: 5-5/8" high x 2" wide x 2 -/8" deep Mounting: Horizontal Model Control, High Limit or Low Limit Aquastat Controller with 65 F to 200 F operating temperature and 5 F to 30 F adj.

6 DifferentialSpecifications Bulb Size: 3/8" x 2-7/8" copper Switching Action: SPDT Maximum Ambient Temperature (F): 150 F Case Dimensions: 5-5/8" high x 2" wide x 2-3/4" deep Mounting: Horizontal or Vertical or Strap-on-mounting Model Relay with 8 F fixed differentialSpecifications Operating Range, High Limit: 120F to 240F Capillary Length: 4-1/2" Switching Action: SPST: High Limit & Circulator Mounting: Horizontal or VerticalModel Materials: Copper Spud Thread Size: 3/4" x 14 NPT Insertion Length: 3" Insulation Depth: 3" Shell (internal diameter): 3/8"WELL ASSEMbLy123871 AModel " NPT x 1/2" NPT Intermittent Hot Surface Pilot Ignition SmartValve Control with slow opening and " wc pressure regulator settingSpecifications Flame Sense: Electrode Type of Gas: Natural Ignition System Type: Intermittent Hot Surface Pilot Ignition Ignition Sequence: Intermittent Pilot Ignition Source: Pilot Ignition Trials To Lockout: Continuous retry PrePurge: 15 seconds Body Pattern: Straight-through Opening Characteristics (standard, step): Slow Opening Ignition Trial Time (sec): 90 sec Model GAS VALVEAQuASTAT COnTROLLERS & RELAyShoneywell PARTSQuICk REfEREnCEICM Cross Reference for oeM and afterMarket ProduCtsICM # Cross REFERENCEFAN BLOWER CONTROLSICM270 CEvcon.

7 2702-300 Rheem: 47-22827-01, 47-22827-81/82/83,47-22828-01/02 Robertshaw: 695-003 ICM271 CCarrier: 302075-3, CES0110017, CES0110018, HH84AA010/011/012/013/020, P771-7002 Robertshaw: 695-100 ICM272 CCarrier: HK61GA001, HK61GA003 Texas Instruments: 2FD-1 ICM275 CCarrier: CES0110019, HH84AA001/003/005/009/014/015/021 Robertshaw: 695-101 ICM276 Carrier: HK51GA003 Rheem: 47-23619-02, 47-23619-03 Robertshaw: 457-23619-03, RS100-833-02 FURNACE CONTROL BOARDSICM280 CGoodman: B18099-06/08/10/13/13S Texas Instruments: 41F-5 UTEC: 1012-933D White-Rodgers: 50T35-730, 50T35-743 ICM281 Carrier: CES0110057-00/01/02 ICM282 Carrier: HK42FZ-004/007/008/009/011/013/014/016, 325878-751 GAS IGNITOR CONTROLSICM283 Honeywell : S8910U-100 Robertshaw: H5780 White-Rodgers: 50E47, 50F47 ICM290 Honeywell : S861U (and compatible Camstat, Fenwal, HSC, Penn-Johnson, Robertshaw and White-Rodgers models)HEAD PRESSURE CONTROLSICM326 HNACT: FM4000 Hoffman: 800, 800A, 800AA, 814-50, 816-10 Ranco: E31 Features & Application Dual function fan delay timer Controls the circulating fan in a heat pump, A/C and forced air systems OFF delay purges ducts of residual air ON delay allows air to reach the proper comfort level prior to energizing the fanSpecifications Voltage: 18-30 VAC Contact ratings: Heat/Cool Speed : 20 amps @ 240 VAC : 10 amps @ 240 VAC Time Delays: Blower ON delay: 30 seconds Blower OFF delay.

8 90, 120, 150, 180 secondsModel & Application Specifically designed to replace popular gas furnace centers Pin selectable blower delays High power, relay output Dual function fan delay timer Controls the circulating fan in heat pump, A/C and forced air systems OFF delay purges ducts for residual air ON delay allows air to reach the proper comfort level prior to energizing the fanSpecifications Voltage: 18-30 VAC Contact ratings: : 20 amps : 10 amps Time Delays: Heat ON delay: 75 seconds Heat OFF delay: 105 seconds Cool OFF delay: 90 secondsModel bLOWER COnTROLSICM272 CFeatures & Application Cooling control module with fan delay Integral low voltage terminal board with field thermostat wiring Electronic air cleaner output High power, relay output DC output for fan relays and 1st stage of electric heater control Interlock circuitry prevents 2nd and 3rd stage electric heat energization without proper fan operation Specifications Voltage: 18-30 VAC Contact ratings: : 20 amps : 10 amps Time Delays: Blower OFF delay: 60 secondsModel & Application Heavy duty heat relay Purges ducts of residual air Integral short cycle protection Specifications Voltage: 18-30 VAC Contact ratings: High.

9 20 amps @ 240 VAC Low: 10 amps @ 240 VAC Time Delays: Heat ON delay: 60 seconds Heat OFF delay: 60-240 seconds Cool OFF delay: 90 secondsICM Controls90 Prices & Specifications subject to change without PARTSICM280 CFeatures & Application Microprocessor-based fan blower Inducer fan outputs Hot surface ignitor output Flame sensor output Gas valve output Status LED for fault codes Twinning compatible with another ICM280 boardSpecifications Voltage: Line (98-132 VAC) @ 60 Hz Fan: 2 HP @ 240 VAC Inducer motor: 7 amps @ 250 VAC Gas valve: 1 amps @ 24 VAC Ignitor: 5 amps @ 120 VACM odel bLOWER COnTROLSF eatures & Application Microprocessor-based fan blower Inducer fan outputs Controls the circulation fan in gas/heat & A/C systems OFF delay purges ducts of residual air Specifications Voltage: 18-30 VAC Outputs: Fan: 20 amps @ 240 VAC Inducer fan: 2 amps Time Delays: Heat ON delay: 60 seconds Heat OFF delay: 120, 150, 180 seconds Cool OFF delay.

10 60 secondsModel COnTROL bOARDSICM281 Features & Application Control gas valve, ignitor, blower motor, inducer, humidifier & air cleaner Microprocessor-based Designed for 100% gas shutoff in case of ignition failure Model selection of 80+ & 90+ furnace operation Reverse polarity protection Secondary brownout voltage protection Heating & cooling fan functions in response to standard thermostat Provides diagnostic LEDs to aid in troubleshooting Twinning compatible with a