Example: tourism industry

Hoval Primo (20/160) - .:Energia-BG:.

Hoval Primo (20/160). Oil/Gas-Boiler Description Subject to alterations Hoval Primo b-i (Oil burner integrated). Boiler 3-pass steel boiler for oil firing Thermolytic secondary heating surface Double joint boiler door Insulation for boiler body with mineral wool mat and special fabric Flue gas outlet on the boiler Casing made of steel plates, red/orange powder coated Instruction manual Calorifier Made of chrome steel and integrated in the boiler Water capacity 128 l Boiler water capacity 180 l Control panel Main switch on/off Safety limit temperature switch 110 . Fuse Trouble indication burner . Plug connection for 1 stage burner Boiler sensor Outdoor sensor Flow sensor VF 100N.

2 Subject to alterations Hoval Primo (20/160) Price Boiler Primo b-i 3-pass steel boiler for oil firing, calorifier made of chrome steel 1.4571 and control panel.

Tags:

  6 2001, Primo, Hoval, Hoval primo

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Hoval Primo (20/160) - .:Energia-BG:.

1 Hoval Primo (20/160). Oil/Gas-Boiler Description Subject to alterations Hoval Primo b-i (Oil burner integrated). Boiler 3-pass steel boiler for oil firing Thermolytic secondary heating surface Double joint boiler door Insulation for boiler body with mineral wool mat and special fabric Flue gas outlet on the boiler Casing made of steel plates, red/orange powder coated Instruction manual Calorifier Made of chrome steel and integrated in the boiler Water capacity 128 l Boiler water capacity 180 l Control panel Main switch on/off Safety limit temperature switch 110 . Fuse Trouble indication burner . Plug connection for 1 stage burner Boiler sensor Outdoor sensor Flow sensor VF 100N.

2 Regulator TopTronic 23S. For 1 mixing circuit Operation switch Temperature adjustment Day/Night . Adaption with Microcomputer Automatic switch summer/winter Regulation of boiler temperature Calorifier loading control Digital display Burner running time meter and count-up Primo Output counter Type kW. Heating armature group 20/160 16-20. Already mounted at the boiler with: Heating circuit pump Motorized 4 way mixing valve 2 ball valves with thermostat Non return valve Piping with fittings Hoval Primo Oil burner Automatic 1-stage oil burner As Primo b-i but without burner With motorized air damper Pre-wired with 7 pin connection Delivery Oil burner tested by Hoval Boiler insulated and cased Adjusted by Hoval for < 1000 m above sea output reduction per 100 m higher level Optional Absorber hood for burner and boiler door Delivery Boiler and burner packed and delivered separately 1.

3 Hoval Primo (20/160). Price Subject to alterations Boiler Primo b-i Part no. 3-pass steel boiler for oil firing, calorifier made of chrome steel and control panel. Oil burner separately packed and delivered. Control panel with TopTronic 23S and sensors are included. Primo Oilburner Out put Type Type kW Pump b-i 20/160 R1-V-L 16-20 M12-1. Boiler Primo 3-pass steel boiler for oil-/gas firing, calorifier made of chrome steel and control panel. (Without burner). Control panel with TopTronic 23S and sensors are included. Primo Output Type kW Pump 20/160 16-20 M12-1 8000529. 2. Hoval Primo (20/160). Price Subject to alterations Control panel with TopTronic regulator Part no.

4 23S for 1 mixing circuit Control panel integrated and in boiler price included. M. Accessories for control system Room station RS 10. for 1 mixing circuit, with room sensor, information, program and correction key 242634. Remote control RFF 60S. for 1 mixing circuit with room sensor, easy program switch and temperature adjustment 2000754. Room temperature sensor RF 40. for 1 mixing circuit 242679. Temperature sensor KT 10-40 S. with 4m cable, for separate delivered calorifier 691215. Flow temperature guard RAM for floor heating with cable and socket 6001889. 3. Hoval Primo (20/160). Price Subject to alterations Heating armature group HAP 25-4R 1''.

5 Part no. For heating circuit with max 60 C. Already in the boiler integrated Accessories Burner cover cap For heat and sound absorbation L = 400 mm 639323. Transport frame For delivery 6000787. Oil volume counter VZO 4K. With filter 6003163. Oil filter OVENTROP 25-40 CG0107. 4. Hoval Primo (20/160). Price Subject to alterations Service Part no. Commissioning 5. Hoval Primo (20/160). Technical data Subject to alterations Primo Type 20/160. Nominal output 1 kW 20. Range of output kW 16-20. Max. firing output kW 21,7. Max. boiler operation temperature2 C 90. Min. boiler operation temperature C 48. Min. boiler return temperature C no min. limit Min.

6 Flue gas temperature C 130. Boiler safety limit temperature C 110. Working- / Test pressure bar 3,0 /4,5. Boiler efficiency at 80/60 C % 92. Nominal efficiency 75/60 C (EN 303) % 92,9. Stand-by deficiency qB at 70 C Watt 288. Flue gas resistance at nominal output, 160 C flue gas temperature, 12,5% CO2, 500m above sea level (+/- 20%) 3 mbar 0,08. Flue gas mass flow 12,5% CO2 (heat oil EL) kg/h 34. Flow resistance boiler4 z-Wert 6,5. Water resistance at 10K mbar 19,2. Water resistance at 20K mbar 4,8. Water flow volume at 10K m h 1,72. Water flow volume at 20K m h 0,86. Boiler water capacity Liter 180. Gas volume m Insulation boiler body mm 80.

7 Weight (incl. casing) kg 200. 3. Acoustic capacity incl. cover cap Heating noise dB(A) 66. Chimney noise dB(A) 80. Fire room dimension x length mm 250x470. Fire room volume m 0,0196. Dimension width mm 654. (with burner and cover cap) length mm 1379. height mm 1660. Calorifier Type 20/160. Water capacity Liter 128. Heating surface m 1,55. Working temperature max. 2 C 65. Working-/Test pressure bar 10/15. Calorifier continuous output dm /h 45 C 484. Calorifier max. output dm /10 min. 45 C 158. dm /10 min. 60 C. Power characteristic number NL 1,5. 1. kW= flue gas losses (LRV 92), boiler water 80 C. 2. Limited to 70 C with control unit 3. Valid for b-i version 4.

8 Flow resistance boiler in mbar = volume flow (m3/h)2 x z 6. Hoval Primo (20/160). Technical data / Flue gas - output - diagram Subject to alterations Heating armature group Flow resistance Primo with heating mbar = (m3/h)2 x z armature group mbar = Flow resistance HAM-25-3-R/L z = 3,43 m3/h = Volume flow Flue gas - output - diagram 190. 180. 170. 160. 150. 140. 130. 120. 110. 16 17 18 19 20. kW= Boiler output with Oil EL. C = Flue gas temperature (DIN 4702) = 1,22 at burner full load (CO2 Oil EL = 12,5%). Oil burner 1-stage to Primo b-i 20. Oil burner Type R1-V-L. Output kW 18-22. Fuel consumption kg/h 1,85. 7. Hoval Primo (20/160). Dimension Subject to alterations Primo (20/160).

9 (all measurements in mm). 87 330. 12 10. 40. 9. 96 1640. 400 129 1553. 120 150. 11. (293) 125. 225. 560 667. 656. 5. 298 4xM8. 103 121 98. 418 336 654 20-30. (verstellbar). 740. 754. 1 Flow R 1". 2 Return R 1". 4 6 3 Cold water R 3/4". 4 Hot water R 3/4". 1 7 5 Drain R 1". 6 Flue gas outlet 129 (outer). 450 125 230 7 Safety flow (expansion). 2 8 Cleaning opening 9 Control panel 3 10 Hand hole cover 13 11 Pocket Boiler 12 Pocket Calorifier 13 Cable connection 14 Burner connection cable 1045. 15 Fire safety switch 1267. 8. Hoval Primo (20/160). Engineering Subject to alterations Standards and Guidelines Outside temperature < 30 C. Following standards and guidelines must be Electric connection of the burner respected: - 1 x 230 V, 50 Hz, 10 A.

10 M 1. - Technical information and installation - For safety reasons the electric cable of 20 100. manual of company Hoval the burner must be that short that the plug 15 100. must be removed when swivelling boiler 10 100. - Hydraulic and technical control regulations door. 5 100. of the local gas supply authority Primo 20/160. - Firing guidelines of local gas works Sound absorption Sound absorption is possible through the m = Chimney height (m). - Fire protection standards following steps: 1 = Min, of chimney and flue gas tube. - Gas directives G1 of the SVGW - Walls, ceilings and floor should be very solidly built, a sound absorber should be - Directives SWKI 97-1 Water treatment for mounted into the air inlet.


Related search queries