HPE ProLiant DL360 Gen10 Server UserGuidePart Number: 869840-006 Published: April 2019 Edition: 6 AbstractThis document is for the person who installs, administers, and troubleshoots servers and storagesystems. hewlett packard Enterprise assumes you are qualified in the servicing of computerequipment and trained in recognizing hazards in products with hazardous energy levels. Copyright 2018-2019 hewlett packard Enterprise Development LPNoticesThe information contained herein is subject to change without notice. The only warranties for hewlett PackardEnterprise products and services are set forth in the express warranty statements accompanying suchproducts and services.

more information, see the latest HPE iLO 5 User Guide on the Hewlett Packard Enterprise website. Front panel LED power fault codes The following table provides a list of power fault codes, and the subsystems that are affected. Not all power faults are used by all servers. Subsystem LED behavior System board 1 flash Processor 2 flashes Memory 3 ...

Tags:

  Guide, User, User guide, Packard, Hewlett packard, Hewlett

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of HPE ProLiant DL360 Gen10 Server User Guide - GfK Etilize

1 HPE ProLiant DL360 Gen10 Server UserGuidePart Number: 869840-006 Published: April 2019 Edition: 6 AbstractThis document is for the person who installs, administers, and troubleshoots servers and storagesystems. hewlett packard Enterprise assumes you are qualified in the servicing of computerequipment and trained in recognizing hazards in products with hazardous energy levels. Copyright 2018-2019 hewlett packard Enterprise Development LPNoticesThe information contained herein is subject to change without notice. The only warranties for hewlett PackardEnterprise products and services are set forth in the express warranty statements accompanying suchproducts and services.

2 Nothing herein should be construed as constituting an additional warranty. HewlettPackard Enterprise shall not be liable for technical or editorial errors or omissions contained computer software. Valid license from hewlett packard Enterprise required for possession, use,or copying. Consistent with FAR and , Commercial Computer Software, Computer SoftwareDocumentation, and Technical Data for Commercial Items are licensed to the Government undervendor's standard commercial to third-party websites take you outside the hewlett packard Enterprise website.

3 hewlett PackardEnterprise has no control over and is not responsible for information outside the hewlett packard and Windows are either registered trademarks or trademarks of Microsoft Corporation in theUnited States and/or other 7 Front panel panel LEDs and button panel LED power fault Insight Display Insight Display combined LED panel 14 Rear panel board maintenance switch slot 18 DIMM label LED drive LED SSD LED drive components and Smart Array P824i-p MR Gen10 up the 30 Powering down the the Server from the 30 Remove the Server from the the access the access 31 Remove the hot-plug the primary PCI riser the primary PCI riser 34 Removing the secondary PCI riser the secondary PCI riser the 8 SFF drive 37 Releasing the cable management arm.

4 And airflow grounding a DC power cable to a DC power the contents of the Server shipping hardware options ..43 Installing the Server into the 44 Installing the operating system with Intelligent boot options in UEFI Boot boot the 46 Hardware options 47 hewlett packard Enterprise product a redundant hot-plug power and NVDIMM population 48 HPE SmartMemory speed a 16GB NVDIMM a high-performance drive the hard drive a hot-plug SAS or SATA a hot-plug SAS or SATA hard 58 Installing the NVMe and replacing an NVMe a uFF drive and SCM drive 60 Removing and replacing a uFF an 8 SFF optical media bay 63 Installing a 2

5 SFF SAS/SATA drive a 2 SFF NVMe drive cage 66 Installing a 2 SFF HPE Smart Carrier (SCM) drive an 8 SFF display port/USB/optical blank the 4 LFF optical drive the rear drive riser cage PCI riser cage an optional primary PCI riser board ..79 Installing the SATA 2280 riser an expansion board in the primary riser 83 Installing an accelerator or GPU in the primary riser 85 Secondary PCI riser a secondary full-height PCI riser cage a secondary low-profile PCIe slot riser cage 90 Installing an expansion board in the secondary riser an accelerator or GPU in the secondary riser 96 Installing an HPE Smart Array P408i-a SR Gen10 Controller 97 Installing an HPE Smart Array P408i-p SR Gen10 Controller 99 Installing an HPE Smart Array P816i-a SR Gen10 Controller 102

6 Installing an HPE Smart Array P824i-p MR Gen10 controller in a configured the operating system with the HPE Smart Array MR Gen10 P824i-p and heatsink 106 Installing a processor heatsink a high-performance , heatsink, and socket the Systems Insight Display power the 4 LFF display port/USB the serial cable the Chassis Intrusion Detection switch a FlexibleLOM 122 Energy pack Smart Storage Smart Storage Hybrid 125 Minimum firmware pack option Trusted Platform Module Gen10 Trusted Platform Module and enabling the HPE TPM Gen10 overview.

7 136 SFF 136 SFF configuration cable SFF configuration cable LFF and configuration Health System 143 Active Health iLO Service RESTful Interface Amplifier Management 146 Intelligent Provisioning Toolkit for Windows and System the boot mode ..149 Secure the Embedded UEFI Shell ..150 HPE Smart Storage MR Storage 152 USB USB ROM and security the system firmware or system 155 Software and system version Pointnext and replacing the system 160 Environmental 160 Power supply 161 HPE 500W Flex Slot Platinum Hot-plug Low Halogen Power 161 HPE 800W Flex Slot Platinum Hot-plug Low Halogen Power 162 HPE 800W Flex Slot Titanium Hot-plug Low Halogen Power 163 HPE 800W Flex Slot Universal Hot-plug Low Halogen Power 164 HPE 800W Flex Slot -48 VDC Hot-plug Low Halogen Power 164 HPE 1600W Flex Slot

8 Platinum Hot-plug Low Halogen Power 166 Hot-plug power supply and other 168 Accessing hewlett packard Enterprise 168 Customer self 169 Regulatory 169 Documentation and 1716 Component identificationFront panel components8 SFFItemDescription1 Serial label pull tab2 Display port (optional)3 Optical drive (optional)4 USB port (optional)5 USB port6iLO Service PortThe operating system does not recognize this port as aUSB drive bays4 LFFItemDescription1 Optical drive blank (optional)2 Serial label pull tab3 Display port (optional)4 USB port (optional)Table ContinuedComponent identification7 ItemDescription5iLO Service PortThe operating system does not recognize this port as aUSB port7 SAS/SATA drive bays10 SFF NVMe/SAS ComboItemDescription1 Serial label pull tab2 Systems Insight Display (optional)3 USB port4 SAS/SATA/NVMe drive baysWhen the 10 SFF NVMe/SAS backplane option is installed,NVMe drives must be installed in bays 9 and 10.

9 The otherbays support a mix of NVMe and SAS panel LEDs and buttons8 SFF/10 SFF8 Component identificationItemDescriptionStatus1 UID button/LED*Solid blue = ActivatedFlashing blue: 1 Hz = Remote management or firmware upgrade inprogress 4 Hz = iLO manual reboot sequence initiated 8 Hz = iLO manual reboot sequence in progressOff = Deactivated2 Power On/Standby button andsystem power LED*Solid green = System onFlashing green = Performing power on sequenceSolid amber = System in standbyOff = No power present**3 Health LED*Solid green = NormalFlashing green = iLO is rebootingFlashing amber = System degradedFlashing red = System critical 4 NIC status LED*Solid green = Link to networkFlashing green = Network activeOff = No network

10 Activity*When all four LEDs described in this table flash simultaneously, a power fault has occurred.**Facility power is not present, power cord is not attached, no power supplies are installed, power supplyfailure has occurred, or the power button cable is disconnected. If the health LED indicates a degraded or critical state, review the system IML or use iLO to review thesystem health identification94 LFFItemDescriptionStatus1 UID button/LED*Solid blue = ActivatedFlashing blue: 1 Hz = Remote management or firmware upgrade inprogress 4 Hz = iLO manual reboot sequence initiated 8 Hz = iLO manual reboot sequence in progressOff = Deactivated2 NIC status LED*Solid green = Link to networkFlashing green = Network activeOff = No network activity3 Health LED*Solid green = NormalFlashing green = iLO is rebootingFlashing amber = System degradedFlashing red = System critical**4 Power On/Standby button andsystem power LED*Solid green = System onFlashing green = Performing power on sequenceSolid amber = System in standbyOff = No power