HR-36 Roof and Wall - AEP Span

HR-36 roof and WallPropertiesStandard FinishesGaugeBase Steel Thickness (in)Yield (ksi)Tensile(ksi)Wt.(lbs/ft2)I+(in4/ft)S +(in3/ft)I-(in4/ft)S-(in3/ft)MetallicCoa tingPaint Dura Tech Dura Tech 5000(polyvinylidene fluoride) orDura Tech mx(metallic polyvinylidene) : The moments of inertia, I+ and I-, presented for determining deflection are: (2 IEffective + IGross)/3HR-36 roof & Wall36 Net Coverage73 16"11 2"Painted side21 16"For most current versions of literature please , WA Phone: 800-733-4955 Fax: 253-272-0791 Customer Service CentersHR-36 is an economical, structural, exposed-fastener roof and wall panel suitable for general is ideal for architectural, commercial, industrial and agricultural roof and wall applications.

All information stated in the product sheet is correct at time of printing and subject to change without notice, check our website for the latest version.

Tags:

  Walls, Roof, Hr 36 roof and wall

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of HR-36 Roof and Wall - AEP Span

1 HR-36 roof and WallPropertiesStandard FinishesGaugeBase Steel Thickness (in)Yield (ksi)Tensile(ksi)Wt.(lbs/ft2)I+(in4/ft)S +(in3/ft)I-(in4/ft)S-(in3/ft)MetallicCoa tingPaint Dura Tech Dura Tech 5000(polyvinylidene fluoride) orDura Tech mx(metallic polyvinylidene) : The moments of inertia, I+ and I-, presented for determining deflection are: (2 IEffective + IGross)/3HR-36 roof & Wall36 Net Coverage73 16"11 2"Painted side21 16"For most current versions of literature please , WA Phone: 800-733-4955 Fax: 253-272-0791 Customer Service CentersHR-36 is an economical, structural, exposed-fastener roof and wall panel suitable for general is ideal for architectural, commercial, industrial and agricultural roof and wall applications.

2 Can be installed as a vertical or horizontal wall. HR-36 is also well suited for open framed canopy or carports features n 36" coverage roof and wall Minimum recommended slope 1 Gauges: 22ga, 24ga and 26ga in standard finishes and 20ga available in ZINCALUME Refer to AEP Span Color Charts for full range of color options and paint Custom manufactured panel lengths: 6'-0" to 50'-0".n Matching fiberglass panels Testing: ASTM E1680 (air infiltration) and ASTM E1646 (water infiltration).n roof assemblies Class A Fire Rated when installed on non-combustible deck or framing per IBC or IRC or when installed in accordance to UL listings (UL790). Wall assemblies rated for fire resistance (UL263) when installed in accordance with UL Building Code Approval Report: # Manufactured in Fontana, CA and Tacoma, features n Short cut sheets from 6'-0" to 1'-0".

3 Additional fees and lead times may 20ga available in standard colors subject to a minimum order size of 4,500 square feet and longer lead 18ga available in bare G-90 galvanized and standard colors subject to a minimum order size of 4,500 square feet and longer lead Custom colors, thick film primer and/or clear coat paint finishes available. Subject to 4,500 square feet minimum order.* (See back)n Perforation options available for an additional charge. Minimum order size 1,500 square feet. Select from standard perforation patterns with open areas of , , , or Crimp curving: GaugeMaximum Length Minimum Outside Radius2430'-0"12"2230'-0"24"2030'-0"24"1 820'-0"48"n Stucco embossed available on 29ga, 26ga, 24ga and 22ga. Subject to minimum order size of 1,500 square DetailPainted sideAll information stated in the product sheet is correct at time of printing and subject to change without notice, check our website for the latest version.

4 2010-2018 ASC Profiles LLC All rights reserved. ZINCALUME is a registered trademark of BlueScope Steel Ltd. 0318 Printed in USA (PS165) 150HR-36 roof and Inward Loads (lbs/ft2) per Span ( )2'-0"2'-6"3 -0"4'-0"5'-0"6'-0"7'-0"8'-0"10'-0"29 Single SpanASD, W/ 300192134754833251912L/180-----2818126 Double SpanASD, W/ 18913296573727201410L/180---------Triple SpanASD, W/ 218154114694532241811L/180---------26 Single SpanASD, W/ 4562922031147351372918L/180----623623158 Double SpanASD, W/ 301205149875740292214L/180---------Tripl e SpanASD, W/ 3512441781077049362818L/180--------1524 Single SpanASD, W/ 63540628215910271524025L/180----89513222 11 Double SpanASD, W/ 5053352371368861453522L/180---------Trip le SpanASD, W/ 60540629016810976564427L/180-------41212 2 Single SpanASD, W/ 87856239021914098725535L/180---219112654 12714 Double SpanASD, W/ 71547133218912285634830L/180---------Tri ple SpanASD.

5 W/ 866576409235152106786039L/180------77522 620 Single SpanASD, W/ 947606421237151105775938L/180----1408151 3417 Double SpanASD, W/ 77851036020513192685133L/180---------Tri ple SpanASD, W/ 946626443254164114846441L/180--------331 8 Single SpanASD, W/ 12618075613152021401037950L/180----18210 5664423 Double SpanASD, W/ 1094720508291187130967347L/180---------T riple SpanASD, W/ 13228806253602331631209259L/180-------84 43 For most current versions of literature please , WA Phone: 800-733-4955 Fax: 253-272-0791 Oil Canning : All flat metal surfaces can display waviness commonly referred to as oil canning . Oil canning is an inherent characteristic of steel products, not a defect, and therefore is not a cause for panel rejection. Customer Service CentersInward LoadsSingle SpanNOTES: Top values based on allowable stress (ASD).

6 Bottom values based on a deflection limit of L/180. - denotes that the allowable load is limited by the panel stress vs. deflection conforms to ASTM A653 (Galvanized) or ASTM A792 (ZINCALUME) structural values are for positive (inward) uniform loading are based on the American Iron and Steel Institute Cold Formed Steel Design Manual (AISI S100-12).Refer to for more complete HR-36 performance SpanTriple Spanw, distributed loadL, spanLLwLLLw* Inquire with AEP Span representative.