17 molded case Circuit Breakers 17/1 Smart Infrastructure, Industrial Control Catalog 2019 Siemens / Industrial Controls Previous folio: new pagec o n t e n t s240V Circuit Breakers600/347V Circuit BreakersBQ BreakersSelection and ordering data 240 VBQ 10 KAICBQH 22 KAICHBQ 65 KAIC1-, 2- & 3-pole up to 125A forcircuit protection up to 240 voltcircuits (UL)QR BreakersSelection and ordering data 240 VQR2 10 KAICQRH-2 25 KAICQR2-H 65 KAICHQR2-H 100 KAIC2- & 3-pole up to 225A for Circuit protection up to 240 voltcircuits (UL)CQD BreakersSelection and ordering data 480/277V 600/347 VCQD 14 KAIC CQD-6 10 KAIC1-, 2- & 3-pole up to 100A for Circuit protection up to 600/347V (CSA) &480/277V (UL) circuitsInformation PageGeneral Data 17/6 17/7 Accessories 17/108 17/110 Information PageGeneral Data 17/8 Accessories 17/108 17/110 Information PageGeneral Data 17/10 Internal Accessories 17/108 17/110 External Accessories 17/111 17/116600/347V Circuit Breakers600V Circuit BreakersGG BreakersSelection and ordering data 480V 600/347 VNGG 25 KAIC 14 KAICHGG 35 KAIC 22 KAICLGG 65 KAIC 25 KAIC1-, 2- & 3-pole up to 125A for Circuit protection up to 600/347 volt circuits (UL/CSA/IEC) 3VA51 BreakersSelection and ordering dataUL Type 480V 600Y/347 VSEAS 25 KAIC 14 KAICMEAS 35 KAIC 18 KAICHEAS 65 KAIC 25 KAIC1-, 2-, 3- & 4-pole up to 125A for Circuit protection u

Jul 23, 2019 · Molded Case Circuit Breakers contents 600V Circuit Breakers Sentron ED Breakers Selection and ordering data 240V 480V 600V ED2 10KAIC — — ED4 65KAIC 18KAIC — ED6 65KAIC 25KAIC 18KAIC 1-, 2- & 3-pole up to 125A for circuit protection up to 600 volt circuits (UL/CSA/IEC) Sentron HED/CED Breakers Selection and ordering data 480V 600/V

Tags:

  Case, Circuit, Molded, Molded case circuit

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of IC Catalog - Section 17 - Circuit Breakers

1 17 molded case Circuit Breakers 17/1 Smart Infrastructure, Industrial Control Catalog 2019 Siemens / Industrial Controls Previous folio: new pagec o n t e n t s240V Circuit Breakers600/347V Circuit BreakersBQ BreakersSelection and ordering data 240 VBQ 10 KAICBQH 22 KAICHBQ 65 KAIC1-, 2- & 3-pole up to 125A forcircuit protection up to 240 voltcircuits (UL)QR BreakersSelection and ordering data 240 VQR2 10 KAICQRH-2 25 KAICQR2-H 65 KAICHQR2-H 100 KAIC2- & 3-pole up to 225A for Circuit protection up to 240 voltcircuits (UL)CQD BreakersSelection and ordering data 480/277V 600/347 VCQD 14 KAIC CQD-6 10 KAIC1-, 2- & 3-pole up to 100A for Circuit protection up to 600/347V (CSA) &480/277V (UL) circuitsInformation PageGeneral Data 17/6 17/7 Accessories 17/108 17/110 Information PageGeneral Data 17/8 Accessories 17/108 17/110 Information PageGeneral Data 17/10 Internal Accessories 17/108 17/110 External Accessories 17/111 17/116600/347V Circuit Breakers600V Circuit BreakersGG BreakersSelection and ordering data 480V 600/347 VNGG 25 KAIC 14 KAICHGG 35 KAIC 22 KAICLGG 65 KAIC 25 KAIC1-, 2- & 3-pole up to 125A for Circuit protection up to 600/347 volt circuits (UL/CSA/IEC) 3VA51 BreakersSelection and ordering dataUL Type 480V 600Y/347 VSEAS 25 KAIC 14 KAICMEAS 35 KAIC 18 KAICHEAS 65 KAIC 25 KAIC1-, 2-, 3- & 4-pole up to 125A for Circuit protection up to 600/347 volt circuits (UL/CSA/IEC))

2 3VA61 BreakersSelection and ordering dataUL Type 480Va 600Y/347 VMDAE 35 KAIC 18 KAICHDAE 65 KAIC 22 KAICCDAE 100 KAIC 35 KAICLDAE 150 KAIC 50 KAIC3- & 4-pole up to 150A for Circuit protection up to 600Y/347 volt circuits (UL/CSA/IEC) Information PageGeneral Data 17/11 Internal Accessories 17/12 External Accessories 17/111 17/116 Information PageBreakers 17/14 17/17 Internal Accessories 17/42 External Accessories 17/43 17/65 Information PageBreakers 17/18 17/21 Internal Accessories 17/42 External Accessories 17/43 17/65 molded case Circuit Breakers Industrial Control Product Catalog 2019 Section ( Section was last modified on 07/23/19)17 molded case Circuit Breakers 17/2 Smart Infrastructure, Industrial Control Catalog 2019 c o n t e n t s600V Circuit Breakers3VA52 BreakersSelection and ordering dataUL Type 480V 600 VMFAS 35 KAIC 18 KAICHFAS 65 KAIC 25 KAICCFAS 100 KAIC 35 KAIC1-, 2-, 3- & 4-pole up to 250A for Circuit protection up to 600 volt circuits (UL/CSA/IEC)3VA62 BreakersSelection and ordering dataUL Type 480V 600Y/347 VMDAE 35 KAIC 18 KAICHDAE 65 KAIC 22 KAICCDAE 100 KAIC 35 KAICLDAE 150 KAIC 50 KAIC3- & 4-pole up to 150A for Circuit protection up to 600Y/347 volt circuits (UL/CSA/IEC) 3VA53 BreakersSelection and ordering dataUL Type 480V 600 VMJAS 35 KAIC 18 KAICHJAS 65 KAIC 25 KAICCJAS 100 KAIC 35 KAIC2(3)-, 3- & 4-pole up to 400A for Circuit protection up to 600 volt circuits (UL/CSA/IEC)

3 Information PageBreakers 17/22 17/23 Internal Accessories 17/42 External Accessories 17/43 17/65 Information PageBreakers 17/24 17/27 Internal Accessories 17/42 External Accessories 17/43 17/65 Information PageBreakers 17/28 17/29 Internal Accessories 17/42 External Accessories 17/43 17/65600V Circuit Breakers3VA63 BreakersSelection and ordering dataUL Type 480V 600 VMJAE 35 KAIC 18 KAICHJAE 65 KAIC 22 KAICCJAE 100 KAIC 35 KAICLJAE 150 KAIC 50 KAIC3- & 4-pole up to 400A for Circuit protection up to 600 volt circuits (UL/CSA/IEC) 3VA54 BreakersSelection and ordering dataUL Type 480V 600Y/347 VMLAS 35 KAIC 20 KAICHLAS 65 KAIC 25 KAICCLAS 100 KAIC 35 KAIC3- & 4-pole up to 600A for Circuit protection up to 600 volts volt circuits (UL/CSA/IEC)3VA64 BreakersSelection and ordering dataUL Type 480V 600 VMLAE 35 KAIC 18 KAICHLAE 65 KAIC 22 KAICCLAE 100 KAIC 35 KAICLLAE 150 KAIC 50 KAIC3- & 4-pole up to 600A for Circuit protection up to 600 volt circuits (UL/CSA/IEC)Information PageBreakers 17/30 17/33 Internal Accessories 17/42 External Accessories 17/43 17/65 Information PageBreakers 17/34 17/35 Internal Accessories 17/42 External Accessories 17/43 17/65 Information PageBreakers 17/36 17/39 Internal Accessories 17/42 External Accessories 17/43 17/65 molded case Circuit Breakers 17 molded case Circuit Breakers 17/3 Smart Infrastructure, Industrial Control Catalog 2019 Siemens / Industrial Controls Previous folio.

4 New pageMolded case Circuit Breakers c o n t e n t s600V Circuit BreakersSentron ED BreakersSelection and ordering data 240V 480V 600 VED2 10 KAIC ED4 65 KAIC 18 KAIC ED6 65 KAIC 25 KAIC 18 KAIC1-, 2- & 3-pole up to 125A for Circuit protection up to 600 volt circuits (UL/CSA/IEC) Sentron HED/CED BreakersSelection and ordering data 480V 600/VHED4 42 KAIC CED6 200 KAIC 100 KAIC1-, 2- & 3-pole up to 125A for Circuit protection up to 600 volt circuits (UL/CSA/IEC) Sentron FD BreakersSelection and ordering data 480V 600 VFD6 35 KAIC 22 KAIC HFD6 65 KAIC 25 KAICHHFD6 100 KAIC 25 KAICCFD6 200 KAIC 100 KAIC2- & 3-pole up to 250A for Circuit protection up to 600 volt circuits (UL/CSA/IEC) Information PageGeneral Data 17/70 Internal Accessories 17/72 External Accessories 17/108 17/115 Information PageGeneral Data 17/71 Internal Accessories 17/72 External Accessories 17/108 17/115 Information PageGeneral Data 17/73 17/74 Internal Accessories 17/75 External Accessories 17/108 17/115600V Circuit BreakersSentron JD BreakersSelection and ordering data 240V 480V 600V JD2 65 KAIC JD6, SJD6-A 65 KAIC 35 KAIC 25 KAICHHJD6 200 KAIC 100 KAIC 50 KAICCJD6,SCJD6-A 200 KAIC 150 KAIC 100 KAICHJD6, SHJD6-A 100 KAIC 65 KAIC 35 KAIC2- & 3-pole up to 400A for Circuit protection up to 600 volt circuits (UL/CSA) Sentron LD BreakersSelection and ordering data 480V 600 VLD6, SLD6-A 35 KAIC 25 KAIC HLD6, SHLD6-A 65 KAIC 25 KAICHHLD6 100 KAIC 50 KAICCLD6, SCLD6-A 150 KAIC 100 KAIC2- & 3-pole up to 600A for Circuit protection up to 600 volt circuits (UL/CSA)

5 Sentron LMD BreakersSelection and ordering data 480V 600/VLMD6 50 KAIC 25 KAICHLMD6 65 KAIC 50 KAIC 2- & 3-pole up to 800A for Circuit protection up to 600 volt circuits (UL/CSA) Information PageGeneral Data 17/76 17/78 Internal Accessories 17/79 External Accessories 17/108 17/115 Information PageGeneral Data 17/80 17/82 Internal Accessories 17/83 External Accessories 17/108 17/115 Information PageGeneral Data 17/84 17/85 Internal Accessories 17/86 External Accessories 17/108 17/11517 molded case Circuit Breakers 17/4 Smart Infrastructure, Industrial Control Catalog 2019 Siemens / Industrial Controls Previous folio: new pageMolded case Circuit Breakers c o n t e n t s600V Circuit BreakersSentron MD BreakersSelection and ordering data 480V 600 VMD, SMD6 50 KAIC 25 KAIC HMD, SHMD6 65 KAIC 50 KAICCMD, SCMD6 100 KAIC 65 KAIC2- & 3-pole up to 800A for Circuit protection up to 600 volt circuits (UL/CSA) Sentron ND BreakersSelection and ordering data 480V 600 VND, SND6 50 KAIC 25 KAICHND, SHND6 65 KAIC 50 KAICCND, SCND6 100 KAIC 65 KAIC2- & 3-pole up to 1600A for Circuit protection up to 600 volt circuits (UL/CSA) Sentron PD BreakersSelection and ordering data 480V 600 VPD, SPD6 50 KAIC 25 KAIC HPD, SHPD6 65 KAIC 50 KAICCPD 100 KAIC 65 KAIC2- & 3-pole up to 1600A for Circuit protection up to 600 volt circuits (UL/CSA)

6 Information PageGeneral Data 17/87 17/89 Internal Accessories 17/90 Information PageGeneral Data 17/91 17/93 Internal Accessories 17/94 Information PageGeneral Data 17/95 17/96 Internal Accessories 17/97600V Circuit Breakers600V Circuit Breakers VL SeriesSentron Circuit Breakers :Additional Information Contents PageCatalog Numbering System 17/69 Magnetic Trip Only ETI Motor Circuit Protectors 7-127 7-129 Adjustable Instantaneous Magnetic Trip Settings 17/98 17/100 molded case Switch Circuit Disconnect 17/101 Digital Solid State Sentron Sensitrip IV Series Trip Units 17/102 17/103WL Power Circuit Breakers 7-136 7-139 Lug Information 17/104 17/106 Breaker Modifications 17/107 Internal Accessories Feature Combinations 17/108 External Accessories 17/111 17/116 Unusual Operating Conditions 17/117 17/118DG VL BreakersSelection and ordering data 480V 600Y/347 VNDG 35 KAIC 18 KAICHDG 65 KAIC 18 KAICLDG 100 KAIC 18 KAIC2- & 3-pole up to 150A for Circuit protection up to 600 voltcircuits (UL/CSA/IEC)

7 FG VL BreakersSelection and ordering data 480V 600 VNFG 35 KAIC 18 KAIC HFG 65 KAIC 20 KAICLFG 100 KAIC 25 KAIC2- & 3-pole up to 150A for Circuit protection up to 600 volt circuits (UL/CSA/IEC) Information PageBreakers & Trip Units 17/125 17/127 Internal Accessories 17/128 External Accessories 17/155 17/166 Information PageGeneral Data 17/129 17/131 Internal Accessories 17/132 External Accessories 17/155 17/16617 molded case Circuit Breakers 17/5 Smart Infrastructure, Industrial Control Catalog 2019 Siemens / Industrial Controls Previous folio: new pageVL Series Circuit Breakers c o n t e n t s600V Circuit Breakers VL SeriesJG VL BreakersSelection and ordering data 480V 600 VNJG 35 KAIC 25 KAIC HJG 65 KAIC 25 KAICLJG 100 KAIC 25 KAIC2- & 3-pole up to 400A for Circuit protection up to 600 volt circuits (UL/CSA/IEC) LG VL BreakersSelection and ordering data 480V 600 VNLG 35 KAIC 18 KAIC HLG 65 KAIC 18 KAIC LLG 100 KAIC 18 KAIC 2- & 3-pole up to 600A for Circuit protection up to 600 volt circuits (UL/CSA/IEC) MG VL BreakersSelection and ordering data 480V 600 VNMG 35 KAIC 25 KAICHMG 65 KAIC 35 KAICLMG 100 KAIC 50 KAIC2- & 3-pole up to 800A for Circuit protection up to 600 volt circuits (UL/CSA/IEC)

8 Information PageGeneral Data 17/133 17/135 Internal Accessories 17/136 External Accessories 17/155 17/166 Information PageGeneral Data 17/137 17/139 Internal Accessories 17/140 External Accessories 17/155 17/166 Information PageGeneral Data 17/141 17/143 Internal Accessories 17/144 External Accessories 17/155 17/166600V Circuit Breakers VL SeriesVL Circuit Breakers :Additional Information Contents PageCatalog Numbering System 17/119 17/120 Technical Overview 17/121 17/122 Trip Unit Overview 17/123 17/124 molded case Switch 17/152 Motor Circuit Protector 17/153VL 600 Volt DC Circuit Breakers 17/154 External Accessories 17/155 17/169 Accessory Locations 17/170 Suffix for Factory Mounted Internal Accessories 17/171 Technical Data 17/172 17/173 Unusual Operating Conditions 17/174 17/175NG VL BreakersSelection and ordering data 480V 600 VNNG 35 KAIC 25 KAIC HNG 65 KAIC 35 KAICLNG 100 KAIC 65 KAIC2- & 3-pole up to 1200A for Circuit protection up to 600 volt circuits (UL/CSA/IEC) PG VL BreakersSelection and ordering data 480V 600 VNPG 35 KAIC 25 KAIC HPG 65 KAIC 35 KAICLPG 100 KAIC 65 KAIC2- & 3-pole up to 1600A for Circuit protection up to 600 volt circuits (UL/CSA/IEC)

9 Information PageGeneral Data 17/145 17/147 Internal Accessories 17/148 External Accessories 17/155 17/166 Information PageGeneral Data 17/149 17/150 Internal Accessories 17/151 External Accessories 17/155 17/16617 molded case Circuit Breakers 17/6 Smart Infrastructure, Industrial Control Catalog 2019 Siemens / Speedfax Previous folio: 6-26 Updated by TA 02/03/11 Circuit BreakersLug-In/Lug-Out with INSTA-WIRE Selection All BQ/BQH/HBQ Circuit Breakers are supplied with load side lugs. If line side lugs are required, add suffix L to Catalog number. Consult Siemens for any additional charge. All standard Circuit Breakers are calibrated for 40 C maximum ambient Built to order. Allow 2-3 weeks for deliverya UL Listed for use with 60/75 wire through 40 amps, UL listed for use with 75 wire only for 50 amps and above, HACR 1A and 1B UL Listed for use on 3-phase grounded B systems 10,000 for this UL Listed for frequent switching applications (SWD).

10 120V AC Fluorescent Shipped 12 per Shipped 6 per Shipped 4 per UL Listed 5KA IR. Refer to Table A on page 17/104 Description Catalog Number Field/Factory Installed120 VAC Shunt Trip add Factory24 VAC Shunt Trip add Factory120V Auxiliary Switch add FactoryBQ / BQH / HBQ Internal Accessories Description Catalog NumberLine Side Lugs add Connect Lug add 400Hz Calibration add hMarine 50 C Ambient add Proofing add ModificationsContinuousCurrent Rating@ 40 CType BQaType BQHType HBQ10,000A IR22,000A IR65,000A IRCatalog NumberCatalog NumberCatalog Number1-Pole (120/240V AC)e15BQ1B015dBQ1B015 HdHB1B015nd20BQ1B020dBQ1B020 HdHB1B020nd25BQ1B025BQ1B025 HnHB1B025n30BQ1B030BQ1B030 HHB1B030n35BQ1B035nBQ1B035 HnHB1B035n40BQ1B040BQ1B040 HHB1B040n45BQ1B045n HB1B045n50BQ1B050BQ1B050 HHB1B050n60BQ1B060n BQ1B060 HnHB1B060n70BQ1B070nBQ1B070 HnHB1B070n2-Pole (Common-Trip 120/240V AC)f15BQ2B015BQ2B015 HHB2B015n20BQ2B020BQ2B020 HHB2B020n25BQ2B025BQ2B025 HnHB2B025n30BQ2B030BQ2B030 HHB2B030n35BQ2B035BQ2B035 HnHB2B035n40BQ2B040BQ2B040 HHB2B040n45BQ2B045 HB2B045n50BQ2B050BQ2B050 HHB2B050n60BQ2B060 BQ2B060 HHB2B060n70BQ2B070BQ2B070 HnHB2B070n80BQ2B080BQ2B080 HnHB2B08090BQ2B090BQ2B090 HnHB2B090n100BQ2B100BQ2B100 HHB2B100110BQ2B110 HB2B110n125BQ2B125BQ2B125 HHB2B1252-Pole (Common-Trip 240V AC)cf15BQ2H015 20BQ2H020 30BQ2H030 40BQ2H040n 50BQ2H050 60BQ2H060 70BQ2H070n 80BQ2H080n 90BQ2H090n 100BQ2H100n 3-Pole (Common-Trip 240V AC)