Example: dental hygienist

IEC Contactor Specifications - Rockwell Automation

Technical DataIEC Contactor SpecificationsBulletin Numbers 100/104-K, 100/104-C, 100/104S-C, 100/104-E, 100S-E, 100/104-D, 100S-D, 100-G, 100Q-C TopicPageProduct Line Overview3 IEC Contactors3 Safety Contactors4100-K/104-K Miniature Contactors5 Product Selection5 Specifications10 Life-Load Curves14 Approximate Dimensions16 Accessories17100-C/104-C, 100S-C/104S-C, 100Q-C Contactors21 Product Selection 100-C/104-C Contactors21 Product Selection 100S-C/104S-C Safety Contactors28 Product Selection 100Q-C Capacitor-switching Contactors38 Specifications40 Life-Load Curves51 Maximum Operating Rates57 Approximate Dimensions61 Accessories65 Renewal Parts70100-E/104-E, 100S-E/104S-E Contactors73 Product Selection 100-E/104-E Contactors73 Product Selectio

Rockwell Automation Publication 100-TD013G-EN-P - August 2018 3 Product Line Overview IEC Contactors Bulletin No. 100-K/104-K 100-C/104-C 100-E/104-E 100-D/104-D 100-G

Tags:

  Specification, Automation, Rockwell automation, Rockwell, 100 g, Contactors, Iec contactor specifications

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of IEC Contactor Specifications - Rockwell Automation

1 Technical DataIEC Contactor SpecificationsBulletin Numbers 100/104-K, 100/104-C, 100/104S-C, 100/104-E, 100S-E, 100/104-D, 100S-D, 100-G, 100Q-C TopicPageProduct Line Overview3 IEC Contactors3 Safety Contactors4100-K/104-K Miniature Contactors5 Product Selection5 Specifications10 Life-Load Curves14 Approximate Dimensions16 Accessories17100-C/104-C, 100S-C/104S-C, 100Q-C Contactors21 Product Selection 100-C/104-C Contactors21 Product Selection 100S-C/104S-C Safety Contactors28 Product Selection 100Q-C Capacitor-switching Contactors38 Specifications40 Life-Load Curves51 Maximum Operating Rates57 Approximate Dimensions61 Accessories65 Renewal Parts70100-E/104-E, 100S-E/104S-E Contactors73 Product Selection 100-E/104-E Contactors73 Product Selection 100S-E Safety Contactors74 Specifications75 Approximate Dimensions92 Accessories96 Renewal Parts99100-D/104-D.

2 100S-D Contactors101 Product Selection 100-D/104-D Contactors101 Product Selection 100S-D Safety Contactors105 Specifications108 Life-Load Curves118 Approximate Dimensions120 Accessories122 Renewal Parts129100-G Contactors131 Product Selection 100-G Contactors131 Specifications132 Life-Load Curves137 Permissible Switching Rate139 Approximate Dimensions141 Accessories143 Renewal Parts144 TopicPage2 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 IEC Contactor SpecificationsAdditional ResourcesThese documents contain additional information concerning related products from Rockwell can view or download publications at To order paper copies of technical documentation, contact your local Allen-Bradley distributor or Rockwell Automation sales Automation Wiring and Grounding Guidelines, publication general guidelines for installing a Rockwell Automation industrial Certifications website, declarations of conformity, certificates.

3 And other certification Automation Publication 100-TD013F-EN-P - November 20173 Product Line OverviewIEC ContactorsBulletin Terminals Thru-holeThru-hole, threaded ( A)Thru-holeSpring Terminals ( A) ( A) Ie12 A97 A2650 A860 A1200 ACurrent AFeatures Mini- contactors Uniform panel mounting dimensions Panel mounting or mounting on 35 mm DIN Rail AC or DC coil control Made of environmentally friendly materials Panel mounting or mounting on 35 mm DIN Rail AC or DC coil control Reversible coil terminals (line or load side)

4 Common accessories Made of environmentally friendly materials Panel mounting electronic coil or optional with PLC with PLC interface Made of environmentally friendly materials Panel mounting only Made of environmentally friendly materials AC or DC coil control (conventional or electronic) Integrated PLC interface (electronic coil) Panel mounting AC or DC coil control Horizontal or vertical interlock Latching 4th poleContacts3 power poles with internal or auxiliary contact, or 4 power front-mounted 2- or 4-pole external auxiliary contact power poles with internal or auxiliary contact or 4 power poles.

5 Optional front- or side-mounted 1-, 2- or 4-pole external auxiliary contact main poles with 2 auxiliary contacts(1 and 1 )Optional side-mounted2-pole external auxiliary contact power poles with external and side-mounted auxiliary contact. Optional side-mounted 2-pole external auxiliary contact blocks3 power poles with and front-mounted auxiliary contact. Optional 4th pole and auxiliary contactsCoil VoltagesAC = , 50/60 HzDC = = , 50/60 HzDC = 50/60 Hz/DCConventional CoilsCat. Nos.

6 : 50 Hz, 60Hz, 50/60 HzDC: DCElectronic CoilsCat. Nos. : 50/60 HzDC: DCCat. Nos. 100-D420AC: 50/60 HzDC: DCCat. Nos. : 50/60 HzDC: DCAC = , 50/60 HzDC = Overload RelaysElectronic or bimetallicElectronic or bimetallicElectronicElectronicElectronic Optional Accessories Front-mount auxiliary contacts Surge suppressors Electronic timers Mechanical interlocks Front or side-mount auxiliary contacts Surge suppressors Electronic or pneumatic timers Mechanical interlocks Mechanical latches Side-mount auxiliary contacts Mechanical interlocks Terminal lugs Terminal shields Connecting bars Side-mount auxiliary contacts Surge suppressors IP20

7 Terminal blocks Terminal shields Terminal covers Connecting components Terminal lugs Mechanical/electrical interlocks Auxiliary contact 4th pole Vertical interlock Horizontal interlock Mechanical latchStandards/Certifications UL CSA IEC CE Marked CCC UL CSA IEC CE Marked CCC EN/IEC CE Marked cULus CCC EAC C-tick UL CSA IEC CE Marked CCC( A - conventional coil; A - electronic coil) UL CSA IEC CE Marked4 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 Safety ContactorsBulletin Terminals Thru-holeThru-hole, threaded ( A) Ie97 A750 A860 ACurrent AFeatures Positively guided/mechanically linked auxiliary contacts Front-mounted auxiliary contacts.

8 Permanently fixed Protective cover to prevent manual operation Red contact housing for easy identification Incorporates IEC 947-5-1 Mechanically Linked symbol Optional gold-plated bifurcated versions AC and DC operating coils SUVA third-party certification Mirror contact performance on auxiliary contacts Red low-power auxiliary contact used for feedback circuit SUVA third-party certification AC and DC operating coils "Mirror Contact" symbol on front Mirror contact performance on auxiliary contacts, which are required in feedback circuit for modern safety applications.

9 The auxiliary contacts will not change state when a power contact welds. SUVA third-party certification AC and DC operating coils "Mirror Contact" symbolContacts3 main poles with mechanically linked or mirror feedback contacts3 main poles with mirror feedback contacts3 main poles with mirror feedback contactsCoil VoltagesAC = , 50/60 HzDC = 50/60 Hz/DCConventional CoilsCat. Nos. : , 50 Hz; , 60Hz; , 50/60 HzDC: CoilsCat. Nos. : , 50/60 HzDC: Nos. 100S-D420AC: 50/60 HzDC: Nos.

10 : , 50/60 HzDC: Accessories Side-mount auxiliary contacts Surge suppressors Electronic timers Mechanical interlocks Side-mount auxiliary contacts Terminal shields Terminal lugs Terminal enlargements Terminal extensions Connection bars for 140G molded case circuit breakers, 140MG motor protection circuit breakers, and 140MG motor circuit protectors Side-mount auxiliary contacts Surge suppressors IP20 terminal blocks Terminal shields Terminal covers Connecting components Terminal lugs Mechanical/electrical interlocksStandards Compliance EN/IEC 60947-4 IEC 60947-5-1 Annex L Mechanically Linked Contacts IEC 60947-4-1 Annex H Mirror Contacts UL 508 CSA No.


Related search queries