Copyright 2015 Tyco Fire Products LP. All rights reserved. iFLOW 200/300 bar total flood fire extinguishing systems design and installationmanualEquipment: iFLOW Publication: 14A-23H Issue: 02 Date: 2015-02iFLOW14A-23H02 2015-02 EQUIPMENT:PUBLICATION:ISSUE No. DATE:DatePageRevision02-20151-2 Contents updated02-20154 Concentration table updated02-20155 Odouriser not required02-20159 Concentrations updated02-201510 Container mass and capacity updated. Formula updated to EN and ISO concentrations updated to current standards02-201513 Flooding factor calculation clarified02-201514 Fig 1 updated (and other instances(02-201515 Formula modified with added state-ments02-201517-19 Equipment description and part No s updated.))

iFLOW 14A-23H 02 2015-02 EQUIPMENT: PUBLICATION: ISSUE No. DATE: Date Page Revision 02-2015 1-2 Contents updated 02-2015 4 Concentration table updated

Tags:

  Extinguishing

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of iFLOW 200/300 bar total flood fire extinguishing …

1 Copyright 2015 Tyco Fire Products LP. All rights reserved. iFLOW 200/300 bar total flood fire extinguishing systems design and installationmanualEquipment: iFLOW Publication: 14A-23H Issue: 02 Date: 2015-02iFLOW14A-23H02 2015-02 EQUIPMENT:PUBLICATION:ISSUE No. DATE:DatePageRevision02-20151-2 Contents updated02-20154 Concentration table updated02-20155 Odouriser not required02-20159 Concentrations updated02-201510 Container mass and capacity updated. Formula updated to EN and ISO concentrations updated to current standards02-201513 Flooding factor calculation clarified02-201514 Fig 1 updated (and other instances(02-201515 Formula modified with added state-ments02-201517-19 Equipment description and part No s updated.))

2 Australian and PESO approved added. 02-201522 Fill weights amended to VdS software. Australian and PESO approved added. 02-201523 Pilot container label added02-201524 Burst disc rating was 400-430 bar02-201525 Burst disc tolerance added02-201526-28 Nozzle Orifice Assy added. Coverage Orifice drilling detail added02-201529 Short bolt removed, actuator pin was listed as brass02-201531 Adaptor 30800001 added02-201533-34 Gauge markings revised, part numbers updated set point amended02-201535 Pilot container tube lengths were 60,250, No s updated .Aus-tralian and PESO approved added.

3 02-201540450,690 long hoses added02-201541 Connectors added 35116260/102-201542 Quantity added02-201544 Double row container added02-201545380 length hose deleted. Specifica-tion changed02-201546 Pilot valve adaptor added02-201547 Non return valve shown as assembly02-201551 Typical fixing crs. added02-201552 Lock assembly added02-201555 Generic manifold info only 02-201558 Safety burst disc replaced with relief valve02-201559-60 Actuation piping components added02-201561 C spanner sizes changed02-201562-64 Sign Part numbers changed, graphic updatedDatePageRevision02-201569 Note container size was 40 litre02-201579series connection shown and voltage corrected02-2015-Caution and warn-ing notes updated to Tyco Std.

4 T-2012097 Copyright 2015 Tyco Fire Products LP. All rights reservediFLOW14A-23H02 2015-02 EQUIPMENT:PUBLICATION:ISSUE No. DATE:DANGER: DANGER indicates a hazardous situation in which a person will experience serious injury or death if the situation is not avoided. The major difference between DANGER and WARNING is the likelihood of being injured or killed. WARNING means it could happen; DANGER means it will :WARNING indicates a hazardous situation in which a person could experience serious personal injury or death if the situation is not types of CAUTION:Type 1 CAUTION, used with the safety alert symbol, indicates a hazardous situation in which a person could experience minor or moderate personal injury if the situation is not avoided.

5 Type 2 CAUTION, used without the safety alert symbol, addresses practices not related to personal injury, such as a system part malfunctioning, property damage, or system failure.! WARNING CAUTION! CAUTION! DANGERNOTICE:NOTICE is used to address general practices or observations related to system function that are not related to personal injury. DANGER, WARNING, CAUTION AND NOTICE ! Due to the inherent risks involved in the fire protection market, it is vital to alert people to the various hazards that may pose a risk to their safety. Warning against the dangers associated with certain procedures or equipment, most importantly, helps to protect customers, company personnel, and company alerts appear often in our system literature and on bulletins, labels, and product packaging.

6 These include:DANGER, WARNING, CAUTION, and NOTICE ALERT TYPESC opyright 2015 Tyco Fire Products LP. All rights reservedPAGE 1 of 100iFLOW14A-23H02 2015-02 EQUIPMENT:PUBLICATION:ISSUE No. DATE:INERGEN total Flooding Systems ( iFLOW 200/300 Bar Engineered Systems)LIST OF CONTENTS1. INTRODUCTION Approvals Temperature Range General Information Description of iFLOW Systems Properties of INERGEN Safety of INERGEN General Physiological Effects Noise Turbulence Visibility Exits Post Discharge Ventilation Material Safety Data Sheet 62.

7 SYSTEM DESIGN Design Standards Determination of INERGEN Quantity Achieved INERGEN Concentration Discharge Time to Achieve Minimum Design Concentration Extended Discharge Connected Reserves Stop Valves and Selector Valve Systems Pipe Size Estimating Design Drawings Room Integrity and Pressurisation Detection and Control Systems Electrical Earthing and Safety Clearances Flow Calculations Introduction/Installation Completing the System Design Nozzle Drilling Details Pipework and Fittings Nozzles 163. EQUIPMENT DESCRIPTIONS iFLOW INERGEN Container and Valve Assemblies 22 Container Labels iFLOW Container Valve 300 bar iFLOW Container Valve 200 bar iFLOW Container Valve Discharge Nozzles 3600 Discharge Nozzles 1800 Discharge Nozzles Pneumatic Actuator Manual Actuator Pneumatic-Manual Actuator Pressure Switch Pressure Gauge Assembly Pilot Container - Standard Gas Metron iFLOW Check Valve iFLOW Discharge Hose iFLOW Discharge Hose Connectors iFLOW Matrix Brackets iFLOW 140 Litre Container Brackets 43 iFLOW

8 140 Litre Container Brackets (Single row) 43 iFLOW 140 Litre Container Brackets (Double Row) iFLOW Actuation Hoses 1/4 in. Bleed Valve Pilot Valve Adaptor Pilot Line Non Return Valve Decompression Screw Selector Valve 49 SECTIONSECTIONPAGEPAGEiFLOW14A-23H02 2015-02 PAGE 2 of 100 EQUIPMENT:PUBLICATION:ISSUE No. Selector Valve Solenoid and Brackets Lock Off Assembly Selector Valve Manifolds iFLOW Manifolds Pressure Relief valve Actuation Piping Special Tools Manual Release Caution Plate Door Caution Plate - Lock-Off Door Caution Plate - No Lock-Off 614.

9 INSTALLATION Delivery and Handling of Equipment Container Fixing Check Valve Installation Discharge Hose Installation Actuation Installation Pilot Container Manual Actuator Lever Pressure Switch with Interlock Selector Valve Selector Valve Solenoid and Manual Actuator Release Systems for Selector Valves Solenoid Valve Pneumatic Actuator Actuation Hose Electrical Installation Pressure Switch Solenoid Valve Pressure Gauge (Contacted Type) Pipe Distribution System Discharge Nozzle Installation 785. COMMISSIONING Pipework Integrity Discharge Pressure Switch Test Pneumatic Actuation Line Test for Single Risk Area Systems Pneumatic Actuation Line Test for Multi Risk Area Systems Pilot Container Solenoid Test Room Integrity Testing 83 SECTIONPAGE6.

10 SERVICING AND MAINTENANCE 897. TYPICAL INSTALLATIONS 948. APPENDIX Modular Manifolds 98 SECTIONPAGEC opyright 2015 Tyco Fire Products LP. All rights reservedPAGE 3 of 100iFLOW14A-23H02 2015-02 EQUIPMENT:PUBLICATION:ISSUE No. DATE:1. INTRODUCTION This manual has been prepared primarily for the use of Designers/Installers of INERGEN ( iFLOW ) Constant Flow Fire extinguishing Equipment. Its purpose is to provide general information on iFLOW and its use in Fire extinguishing Systems and to give more detailed information covering the design, installation, testing and servicing of these : The manual covers the minimum requirements for the design of total Flooding Systems.