Example: bachelor of science

IM Series - Farnell element14

IM SeriesAXICOM Signal and Telecom Relays108-98001 Rev. KAll specifications subject to change. Consult Tyco Electronics for latest specifications. 2 of 28 AXICOM Telecom, Signal and RF RelaysIM RelayIndexDescription 3 Selection Guide / Relay Code 4 Coil Data and Ordering Information - IM 5- IM-A 10- IM-B 12- IM-C 14- IM-D 16- IM-E 18 Contact Data 20 Insulation 22 General Data 23 Coil Operating Range 24 Soldering Condition 25 Packing 26UL 508 File No. E 111441UL 60950 IEC/EN60950 IEC Ref. Cert. No. 3270 DisclaimerWhile Tyco Electronics and its affiliates referenced herein have made every reasonable effort to ensure the accuracy of the information contained in this catalog, Tyco Electro-nics cannot assure that this information is error free. For this reason, Tyco Electronics does not make any represen-tation or offer any guarantee that such information is accu-rate, correct, reliable or current.

108-98001 Rev. K All specifications subject to change. Consult Tyco Electronics for latest specifications. 3 of 28 AXICOM Telecom, Signal and RF Relays

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of IM Series - Farnell element14

1 IM SeriesAXICOM Signal and Telecom Relays108-98001 Rev. KAll specifications subject to change. Consult Tyco Electronics for latest specifications. 2 of 28 AXICOM Telecom, Signal and RF RelaysIM RelayIndexDescription 3 Selection Guide / Relay Code 4 Coil Data and Ordering Information - IM 5- IM-A 10- IM-B 12- IM-C 14- IM-D 16- IM-E 18 Contact Data 20 Insulation 22 General Data 23 Coil Operating Range 24 Soldering Condition 25 Packing 26UL 508 File No. E 111441UL 60950 IEC/EN60950 IEC Ref. Cert. No. 3270 DisclaimerWhile Tyco Electronics and its affiliates referenced herein have made every reasonable effort to ensure the accuracy of the information contained in this catalog, Tyco Electro-nics cannot assure that this information is error free. For this reason, Tyco Electronics does not make any represen-tation or offer any guarantee that such information is accu-rate, correct, reliable or current.

2 Tyco Electronics reserves the right to make any adjustments to the information at any time. Tyco Electronics expressly disclaims any implied warranty regarding the information contained herein, inclu-ding, but not limited to, the implied warranties of merchan-tability or fitness for a particular purpose. Tyco Electronics only obligations are those stated in Tyco Electronics Stan-dard Terms and Conditions of Sale. Tyco Electronics will in no case be liable for any incidental, indirect or consequen-tial damages arising from or in connection with, including, but not limited to, the sale, resale, use or misuse of its pro-ducts. Users should rely on their own judgment to evaluate the suitability of a product for a certain purpose and test each product for its intended application. In case of any potential ambiguities or questions, please don t hesitate to contact us for Rev.

3 KAll specifications subject to change. Consult Tyco Electronics for latest specifications. 3 of 28 AXICOM Telecom, Signal and RF RelaysIM RelayIM Relay1 and 2 pole telecom/signal relay, polarizedThrough Hole Types (THT), standard version with mm, narrow with mm between the terminal rows or Surface Mount Type (SMT)Relay Types: non latching with 1 coil latching with 1 coilConfigurations: 2 pole changeover / DPDT / 2 Form C IM 2 pole break / DPST NC / 2 Form B IMD 2 pole make / DPST NO / 2 Form A IME 1 pole changeover / SPDT / 1 Form C IMC 1 pole break / SPST NC / 1 Form B IMA 1 pole make / SPST NO / 1 Form A IMBROHS compliant (Directive 2002/95/EC) as per product date code 0438 / Halogen freeFeatures- Minimum board-space 60 mm2- Slim line 10 x 6 mm, x inch and- Low profile mm, inch - Switching power 60 W / VA- Switching voltage 220 VDC / 250 VAC- Switching current 2 / 5 A- Bifurcated contacts- Low coil power consumption Latching version o 100 mW Non latching version o 140 mW standard o 100 mW high sensitive version o 50 mW ultra high sensitive version- High dielectric and surge capability ( s and 10/700 s)

4 Meets Telcordia GR1089, FCC Part 68 and ITU-T K20, K21 and K45 requirements o up to 2500 Vrms between open contacts o up to 3000 Vrms between coil and contacts- Meets 1500 Vrms (high dielectric version) between open contacts as well as Australian clearance requirements- High mechanical shock resistance up to 300G functional and 500G survivalTypical Applications- Telecommunication o Access and transmission equipment o Optical Network Terminals o Modems- Office and business equipment- Consumer electronics- Measurement and Test equipment- Industrial control- Medical equipment- Automotive applicationsVersions- High Dielectric Version C Type- High Current Version D Type- High Contact Resistance Stability Version P TypeInsulation CategorySupplementary insulation according IEC / EN 60950 Working voltage 300 VrmsMains supply voltage 250 VrmsRepetitive peak voltage 2500 VPollution degree Internal: 1 External: 2 Flammability classification V-0 Maximum operating temperature 85 CMeets Australien Requirements between open contacts108-98001 Rev.

5 KAll specifications subject to change. Consult Tyco Electronics for latest specifications. 4 of 28 AXICOM Telecom, Signal and RF RelaysIM Relay IMRelay CodeSelection GuidePacking: S = Tube R = ReelTerminal shape: T = THT-Standard N = THT-Narrow J = SMT-J-Leg G = SMT-Gull Wing K = THT- ShortPerformance Type: Nil = Standard Version C = High Dielectric Version D = High Current Version P = High contact stability VersionCoil Version: see coil dataRelay Type: NIL = 2 pole changeover / DPDT / 2 Form C D = 2 pole break / DPST NC / 2 Form B E = 2 pole make / DPST NO / 2 Form A A = 1 pole break / SPST NC / 1 Form B B = 1 pole make / SPST NO / 1 Form A C = 1 pole changeover / SPDT / 1 Form C IMRelayIM RelayIM-A1 Pole break1 Form BSPST NCIM-B1 Pole make1 Form ASPST NOIM-C1 Pole changeover1 Form C SPDTIM2 Pole changeover2 Form CDPDTIM-D2 Pole break2 Form BDPST NCIM-E2 Pole make2 Form A DPST NOIM-BHigh Dielectric C IMStandardIMHigh Dielectric C IM-AHigh Dielectric C IMHigh Contact IMHigh Current D Stability P IM-CHigh Dielectric C IM-CStandard108-98001 Rev.

6 KAll specifications subject to change. Consult Tyco Electronics for latest specifications. 5 of 28 AXICOM Telecom, Signal and RF RelaysIM Relay 2 Pole Changeover / 2 Form C / DPDTD imensions Dimensions in mmTHT VersionMounting Hole LayoutView onto the component side of the PCB (top view)Non-Latching Typenot energized conditionLatching Type, 1 Coilreset conditionIM THTS tandardIM THTN arrowIM SMTGull WingsIM VersionStandard VersionNarrow VersionSolder Pad LayoutView onto the component side of the PCB (top view)Gull WingsJ-LegsStandard VersionNarrow VersionGull Wings min. min. AssignmentRelay top viewContacts in reset position. Contact position might change during trans-portation and must be reset before Rev.

7 KAll specifications subject to change. Consult Tyco Electronics for latest specifications. 6 of 28 AXICOM Telecom, Signal and RF RelaysIM Relay 2 Pole Changeover / 2 Form C / DPDTCoil Data (values at 23 C) Ordering InformationNominalvoltageUnomOperate/set voltage rangeRelease/reset voltageMinimumCoilpowerCoilResistanceRel aycodeTyco ElectronicspartnumberMinimumvoltage UminMaximumvoltage UmaxVdcVdcVdcVdcmW / 10 %Standard VersionTHT Standard non-latching 1 coil 1462037-4 Narrow non-latching 1 coil 1-1462038-1 J-Legs non-latching 1 coil 4-1462037-0 Gull Wings non-latching 1 coil 1462037-1 1462037-9 coil versions are available on Rev. KAll specifications subject to change. Consult Tyco Electronics for latest specifications. 7 of 28 AXICOM Telecom, Signal and RF RelaysIM Relay 2 Pole Changeover / 2 Form C / DPDTCoil Data (values at 23 C) Ordering InformationNominalvoltageUnomOperate/set voltage rangeRelease/reset voltageMinimumCoilpowerCoilResistanceRel aycodeTyco ElectronicspartnumberMinimumvoltage UminMaximumvoltage UmaxVdcVdcVdcVdcmW / 10 %Latching VersionTHT Standard latching 1 coil 5-1462037-3 Narrow latching 1 coil 1-1462038-9 J-Legs latching 1 coil 5-1462037-5 Gull Wings latching 1 coil 5-1462037-4 coil versions are available on Rev.

8 KAll specifications subject to change. Consult Tyco Electronics for latest specifications. 8 of 28 AXICOM Telecom, Signal and RF RelaysIM Relay 2 Pole Changeover / 2 Form C / DPDTCoil Data (values at 23 C) Ordering InformationNominalvoltageUnomOperate/set voltage rangeRelease/reset voltageMinimumCoilpowerCoilResistanceRel aycodeTyco ElectronicspartnumberMinimumvoltage UminMaximumvoltage UmaxVdcVdcVdcVdcmW / 10 %High Sensitive VersionSMT Gull Wings non-latching 1 coil 1462039-3 1462039-4 1462039-5 1462039-6 High Dielectric VersionSMT Gull Wings non-latching 1 coil 1462038-4 1462038-1 1462038-2 1462038-3 9-1462037-9 Gull Wings latching 1 9-1462038-7 High Current/Low Contact Resistance VersionSMT Gull Wings non-latching 1 coil 9-1462038-8 9-1462038-9 1-1462039-7 1-1462039-8 THT non-latching 1 coil Gull Wings latching 1 coil 1462039-9 1-1462039-9 Further coil versions are available on Rev.

9 KAll specifications subject to change. Consult Tyco Electronics for latest specifications. 9 of 28 AXICOM Telecom, Signal and RF RelaysIM Relay 2 Pole Changeover / 2 Form C / DPDTCoil Data (values at 23 C) Ordering InformationNominalvoltageUnomOperate/set voltage rangeRelease/reset voltageMinimumCoilpowerCoilResistanceRel aycodeTyco ElectronicspartnumberMinimumvoltage UminMaximumvoltage UmaxVdcVdcVdcVdcmW / 10 %Ultra High Sensitive VersionSMT Gull Wings non-latching 1 coil 2-1462039-7 2-1462039-9 3-1462039-1 THT non-latching 1 coil 2-1462039-8 3-1462039-0 3-1462039-2 High Contact Stability VersionSMT Gull Wings non-latching 1 coil 5-1462039-4 5-1462039-5 5-1462039-6 SMT Gull Wings latching 1 coil 5-1462039-7 THT Narrow non-latching 1 coil 5-1462039-8 5-1462039-9 6-1462039-0 THT Narrow latching 1 coil 6-1462039-1 Further coil versions are available on Rev.

10 KAll specifications subject to change. Consult Tyco Electronics for latest specifications. 10 of 28 AXICOM Telecom, Signal and RF RelaysIM-A Relay 1 Pole Break / 1 Form B / SPST NCIM THTS tandardIM SMTGull VersionStandard VersionSMT VersionMounting Hole LayoutView onto the component side of the PCB (top view)Solder Pad LayoutView onto the component side of the PCB (top view)Dimensions IM-A Dimensions in mmTerminal AssignmentRelay top viewNon-Latching Typenot energized conditionLatching Type, 1 Coilreset conditionCoplanarity Rev. KAll specifications subject to change. Consult Tyco Electronics for latest specifications. 11 of 28 AXICOM Telecom, Signal and RF RelaysIM-A Relay 1 Pole Break / 1 Form B / SPST NCCoil Data (values at 23 C) Ordering InformationNominalvoltageUnomOperate/set voltage rangeRelease/reset voltageMinimumCoilpowerCoilResistanceRel aycodeTycoElectronicspartnumberMinimumvo ltage UminMaximumvoltage UmaxVdcVdcVdcVdcmW / 10 %IM-ASMT Gull Wings non-latching 1 coil 1462040-1 1462040-2 1462040-4 THT non-latching 1 coil 1462040-5 1462040-6 1462040-7 1462040-8 Further coil versions are available on Rev.