Owner's Manual Notice d'utilisation Manual del Propietario Do not use this equipment before reading this manual! IMPACT 440. Airless Sprayer Model 805-015. Model 805-016. Model 805-019. Register your product online at: NOTE: This manual contains important warnings and instructions. Please read and retain for reference. Serial Number* _____. * See page 46 for location 1116 Titan Tool Inc. All Rights Reserved. Form No. 805-903V. Important Safety Information conductive or grounded high-pressure airless paint sprayer hoses Read all safety information before operating the specified by the manufacturer.

SPRAY Valve Oiler button Operation This equipment produces a fluid stream at extremely high pressure. read and understand the warnings in the Safety Precautions section at the front of this manual before operating this equipment. using the Gun Trigger Lock Always engage the gun’s trigger lock when the gun is not in use. 1.

Tags:

  Impact, Spray

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of IMPACT 440 - Titan Tool

1 Owner's Manual Notice d'utilisation Manual del Propietario Do not use this equipment before reading this manual! IMPACT 440. Airless Sprayer Model 805-015. Model 805-016. Model 805-019. Register your product online at: NOTE: This manual contains important warnings and instructions. Please read and retain for reference. Serial Number* _____. * See page 46 for location 1116 Titan Tool Inc. All Rights Reserved. Form No. 805-903V. Important Safety Information conductive or grounded high-pressure airless paint sprayer hoses Read all safety information before operating the specified by the manufacturer.

2 Equipment. Save these instructions. Verify that all containers and collection systems are grounded to prevent static discharge. Indicates a hazardous situation which, if not avoided, Connect to a grounded outlet and use grounded extension cords could result in death or serious injury. (electric models only). Do not use a 3 to 2 adapter. To reduce the risks of fire or explosion, electrical shock Do not use a paint or solvent containing halogenated and the injury to persons, read and understand all hydrocarbons. Such as chlorine, bleach mildewcide, methylene instructions included in this manual.

3 Be familiar with the chloride and trichloroethane. They are not compatible with controls and proper usage of the equipment. aluminum. Contact the coating supplier about compatibility of material with aluminum. Keep spray area well ventilated. Keep a good supply of fresh air Grounding Instructions moving through the area to keep the air within the spray area free This product must be grounded. In the event of an electrical short circuit, from accumulation of flammable vapors. Keep pump assembly in grounding reduces the risk of electric shock by providing an escape wire well ventilated area.

4 Do not spray pump assembly. for the electric current. This product is equipped with a cord having a Do not smoke in the spray area. grounding wire with an appropriate grounding plug. The plug must Do not operate light switches, engines, or similar spark producing be plugged into an outlet that is properly installed and grounded in products in the spray area. accordance with all local codes and ordinances. Keep area clean and free of paint or solvent containers, rags, and other flammable materials. warning - Improper installation of the grounding plug Know the contents of the paint and solvents being sprayed.

5 Can result in a risk of electric shock. Read all Material Safety Data Sheets (SDS) and container labels provided with the paints and solvents. Follow the paint and If repair or replacement of the cord or plug is necessary, do not connect solvent manufacture's safety instructions. the green grounding wire to either flat blade terminal. The wire with insulation having a green outer surface with or without yellow stripes is Place pump at least 25 feet ( meters) from the spray object in the grounding wire and must be connected to the grounding pin.

6 A well ventilated area (add more hose if necessary). Flammable vapors are often heavier than air. Floor area must be extremely Check with a qualified electrician or serviceman if the grounding well ventilated. The pump contains arcing parts that emit sparks instructions are not completely understood, or if you are in doubt as and can ignite vapors. to whether the product is properly grounded. Do not modify the plug provided. If the plug will not fit the outlet, have the proper outlet Plastic can cause static sparks. Never hang plastic to enclose spray installed by a qualified electrician.

7 Area. Do not use plastic drop cloths when spraying flammable material. This product is for use on a nominal 120 volt circuit and has a grounding plug that looks like the plug illustrated below. Make sure that the product Fire extinguisher equipment shall be present and working. is connected to an outlet having the same configuration as the plug. No adapter should be used with this product. Grounded Outlet WARNING: Injection injury A high pressure paint stream produced by this equipment can pierce the skin and underlying tissues, leading to serious injury and possible amputation.

8 See a physician Grounding Pin immediately. Cover for grounded outlet box PREVENTION: important: When the sprayer is used with a generator Do not aim the gun at, or spray any person or animal. or uncontrolled line voltage, the use of Titan 's Line Surge Keep hands and other body parts away from the discharge. For Protector (P/N 800-935) is recommended. example, do not try to stop leaks with any part of the body. NEVER put your hand in front of the gun. Gloves will not provide protection against an injection injury. ALWAYS keep the tip guard in place while spraying.

9 The tip guard provides some protection but is mainly a warning device. WARNING: EXPLOSION OR FIRE. Only use a nozzle tip specified by the manufacturer. Solvent and paint fumes can explode or ignite. Property damage and/or severe injury can occur. Use caution when cleaning and changing nozzle tips. In the case where the nozzle tip clogs while spraying, ALWAYS lock gun trigger, shut pump off, and release all pressure before PREVENTION: servicing, cleaning tip or guard, or changing tip. Pressure will not be released by turning off the motor. The PRIME/ spray .

10 Do not spray flammable or combustible materials near an open valve or pressure bleed valve must be turned to their appropriate flame, pilot lights or sources of ignition such as hot objects, positions to relieve system pressure. Refer to PRESSURE RELIEF. cigarettes, motors, electrical equipment and electrical appliances. PROCEDURE described in the pump manual. Avoid creating sparks from connecting and disconnecting power cords. Do not leave the unit energized or under pressure while unattended. When the unit is not in use, turn off the unit and Use extreme caution when using materials with a flashpoint relieve the pressure in accordance with the manufacturer's below 100 F (38 C).