Example: biology

Indirect-Fired Water Heaters - Amazon S3

indirect -FiredWater HeatersPremier Series Dual Coil CommercialHere s how traditional Water Heaters compare:The growing importance of energy efficiency and today s high fuel prices means there s never been a better time to install an AMTROL BoilerMate indirect Water heater. Widely regarded as the least expensive means of heating Water , each BoilerMate includes features that save fuel while delivering endless hot Water . In fact, you can cut up to 60% from your hot Water fuel bill! Instantaneous Wall-HungOften touted as a modern, cost-saving alternative, instantaneous Heaters haven t lived up to the hype. In addition to their high purchase price, instantaneous Heaters require a separate fuel connection and exhaust venting.

Indirect-Fired. Water Heaters. ... BoilerMate ® indirect water heater. Widely regarded as the least expensive means of heating water, each BoilerMate includes features that save fuel while delivering endless hot water. In fact, you can cut up to 60% from your hot water fuel bill!

Tags:

  Amazon, Water, Fired, Heaters, Indirect, Water heaters, Amazon s3, Indirect fired water heaters, Indirect water, Indirect fired

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Indirect-Fired Water Heaters - Amazon S3

1 indirect -FiredWater HeatersPremier Series Dual Coil CommercialHere s how traditional Water Heaters compare:The growing importance of energy efficiency and today s high fuel prices means there s never been a better time to install an AMTROL BoilerMate indirect Water heater. Widely regarded as the least expensive means of heating Water , each BoilerMate includes features that save fuel while delivering endless hot Water . In fact, you can cut up to 60% from your hot Water fuel bill! Instantaneous Wall-HungOften touted as a modern, cost-saving alternative, instantaneous Heaters haven t lived up to the hype. In addition to their high purchase price, instantaneous Heaters require a separate fuel connection and exhaust venting.

2 Performance is also limited by the heater s ability to keep up with demand. Because they have no reserve storage, running more than one fixture at a time can push some instantaneous Heaters to their limit. Finally, in homes with high usage, efficiency is typically no more than 8-14% better than with old-fashioned tank-type Heaters , meaning it can take over 20 years to achieve payback. Tankless Coil in BoilerTankless coils use the boiler as their energy source. Unfortunately, they do not have any storage, meaning that the boiler must remain hot 24 hours a day, 365 days a year. This makes tankless coils the least efficient Water heating method for most homes. Combine this with poor temperature regulation and limited performance, and you ll understand why these are considered a poor method of generating hot Water .

3 Gas and Oil- fired StorageOnce the old standby, technology has passed these Heaters by. With a typical Energy Factor (ef) of about 60%, these Heaters waste almost as much fuel as they use to heat Water . Even so-called high efficiency models only increase efficiency by a small amount while costing considerably Premier SeriesBoilerMate Premier Series are designed for customers who want the best indirect available. With features like a high-grade stainless steel construction, removable heat exchanger and superior insulation, the Premier Series is perfect for larger homes and high-end :Stainless steel construction High grade 316-L stainless steel resists aggressive Water conditions Thick, urethane foam insulation loses less than 1/2 F per hour in standby Rugged, dent-resistant plastic outer jacketLarger sizes for bigger homes 60, 80 and119-gallon storage for multiple fixtures Larger size handles whirlpool baths High-flow domestic Water connections with no dip tube provides minimal pressure drop Multiple heat exchanger options Double-wall option to meet stringent plumbing codes Removable for cleaning or service Multiple pass design allows high boiler flow with minimal pressure dropModels & SpecificationsMODELNUMBERCAPACITy(gallon s)HEIGHT(inches)DIAMETER(inches)

4 SHIPPING WEIGHT (lbs.)COLD WATERINLET NPTMHOT WATEROUTLET NPTFBOILERSUPPLyBOILERRETURNWHS-60605426 1601 1 3/4 NPTM3/4 NPTMWHS-808066261701 1 3/4 NPTM3/4 NPTMWHS-1201197129 3/42101 1 3/4 NPTM3/4 NPTMWHS-60DW6054261781 1 3/4 Union Sweat3/4 Union SweatWHS-80DW8066261881 1 3/4 Union Sweat3/4 Union SweatWHS-60 BOILER OUTPUT(5 gpm input- to BoilerMate)1 FIRST-HOUR RATING(90 F rise)2 CONTINUOUSFLOW(70 F rise steady state)BTU/HRGPHGPH40,0001056960,00013310 480,000160139100,000187173120,0002142081 40,000241242 WHS-8040,0001236960,00015010480,00017713 9100,000204173120,000231208140,000258242 WHS-12040,0001586960,00018510480,0002121 39100,000239173120,000266208140,00029324 2 PerformanceOption Codes: Z = Electromechanical thermostat, packaged without circulator; DW = Heat exchanger with double-wall tubing, vented to atmosphere IAPMO listed; No code = Smart Control packaged without circulator (Ex: WHS-80)WHS-80 ZWHS-120 ZWHS-60 ZFeatures 10-Year Limited CommercialBoilerMate Commercial indirects take performance to a new level.

5 With recovery rates approaching 500 gallons per hour, there s a commercial BoilerMate to meet any hot Water :Stainless steel construction (60, 80, 119-gallon models) High grade 316-L stainless steel resists aggressive Water conditions Thick, urethane foam insulation loses less than 1/2 F per hour Rugged, dent-resistant plastic outer jacket High temperature capability for commercial washdown and disinfectionCompact versions available (41-gallon models) 41-gallons to fit tight mechanical rooms High output exchanger transfers up to 280,000 BTU/HR Narrow 22 diameter makes multi-heater installations easyHigh output for large demands Heat transfer up to 280,000 BTU/HR continuous 60, 80 or 119-gallon storage capacity Large domestic Water connections to support high flows 180 F aquastat standard on stainless steel models Purpose built commercial heat exchanger Available double-wall option to meet stringent plumbing codes Common flange design for easy changeout and upgrade Removable for cleaning or service Multiple pass design allows high boiler flow with minimal pressure dropModels & SpecificationsWH-7C.

6 WH-7 CDWBOILER OUTPUT(7 gpm input- to BoilerMate)1 FIRST-HOUR RATING(90 F rise)2 CONTINUOUSFLOW(70 F rise steady state)BTU/HRGPHGPH100,000170172120,00019 7207140,000223241160,000250275180,000277 310200,000304344220,000331379240,000*357 413260,000384448280,000411482 WHS-80ZC, WHS-80 ZCDW100,000202173120,000229208140,000256 242160,000283277180,000310312200,0003373 46220,000363379240,000*389413260,0004164 48280,000443482 WHS-60ZC, WHS-60 ZCDWBOILER OUTPUT(7 gpm input- to BoilerMate)1 FIRST-HOUR RATING(90 F rise)2 CONTINUOUSFLOW(70 F rise steady state)BTU/HRGPHGPH100,000185173120,00021 2208140,000239242160,000266277180,000293 312200,000320346220,000346379240,000*372 413260,000399448280,000426482 WHS-120ZC, WHS-80 ZCDW100,000236173120,000263208140,000289 242160,000316275180,000343310200,0003703 44220,000397379240,000*423413260,0004504 48280,000477482 PerformanceMODELNUMBERCAPACITy(gallons)H EIGHT(inches)DIAMETER(inches)SHIPPING WEIGHT (lbs.)

7 COLD WATERINLET NPTMHOT WATEROUTLET NPTFBOILERSUPPLyBOILERRETURNWH-7C4148221 443/4 3/4 3/4 NPTM3/4 NPTMWH-7C-DW4148221513/4 3/4 3/4 Union Sweat3/4 Union SweatWHS-60ZC6054261681 1 1 NPTM1 NPTMWHS-60-ZCDW6054261781 1 1 Union Sweat1 Union SweatWHS-80ZC8066261781 1 1 NPTM1 NPTMWHS-80-ZCDW8066261881 1 1 Union Sweat1 Union SweatWHS-120-ZC1197129 3/42181 1 1 NPTM1 NPTMWHS-120-ZCDW1197129 3/42281 1 1 Union Sweat1 Union SweatMaximum BTU transfer with 180 F boiler Water : *CDW Models = 240,000 Features 5-Year Limited BoilerMate Dual Coil provides the ultimate in hot Water generation. With twin heat exchangers, the Dual Coil has the ability to provide hot Water where other indirects fall short.

8 This means fewer Heaters in a smaller footprint for your commercial jobs. In fact, just two Dual Coil units can supply hot Water to nearly 100 hotel rooms!BoilerMate Dual Coil Features:Superior hot Water output Up to 688 gallons per hour continuous flow 180 F domestic Water temperature capability Unique applications like radiant, solar, pool heatingEfficient, space saving design Each Dual Coil can replace large storage tanks or multiple Heaters Urethane foam insulation loses less than 1/2 F per hour in standby Narrow diameter fits through standard doorways and offers a small footprintCode compliant design Available double-wall option for use with all standard boiler system fluids ASME-exempt design saves cost and simplifies code inspection process Includes correct T & P safety relief valve Multiple pass coil design allows high boiler flow with minimal pressure dropSimplified maintenance Removable heat exchangers facilitate easy cleaning Readily accessible connections for simple hookup and service Uses standard circulator pumps and Water

9 Heater accessories for easy maintenanceModels & SpecificationsDC-80 / DC-80 DWBOILER OUTPUT BTU/HRFIRST-HOUR RATING(90 F rise)GALLONSCONTINUOUSFLOW(70 F rise steady state)GPH80,000117139100,000202173120,00 0229208140,000256242160,000277277180,000 304312200,000331346240,000357413280,0003 84482320,000411551 360,000*550620400,000603688DC-120 / DC-120 DWBOILER OUTPUT BTU/HRFIRST-HOUR RATING(90 F rise)GALLONSCONTINUOUSFLOW(70 F rise steady state)GPH80,000209139100,000236173120,00 0263208140,000289242160,000316277180,000 343312200,000370346240,000423413280,0004 77482320,000530551 360,000*584620400,000637688 PerformanceMODELNUMBERCAPACITy(gallons)H EIGHT(inches)DIAMETER(inches)SHIPPING WEIGHT (lbs.)COLD WATERINLET NPTMHOT WATEROUTLET NPTFBOTTOM COILCONNECTIONSTOP COILCONNECTIONSTOP COILTyPEDC-808066261983/4 3/4 3/4 NPTM3/4 NPTMS ingle WallDC-80DW8069262083/4 3/4 3/4 Union Sweat3/4 Union SweatDouble WallDC-1201197129 3/42383/4 3/4 3/4 NPTM3/4 NPTMS ingle WallDC-120DW1197429 3/42483/4 3/4 3/4 Union Sweat3/4 Union SweatDouble Wall* Double wall models maximum 360,000 BTUH with both Coil OnlyBoth Coils as InputFeatures 10-Year Limited Headquarters1400 Division Road, West Warwick, RI USA 02893 Telephone: 401-884-6300 Fax: 401-884-5276 AMTROL Canada, Shoemaker Street, Kitchener, Ontario N2E 3B3 Telephone: 519-748-1138 Fax.