Example: bachelor of science

INDUSTRIAL AIR COMPRESSOR

LS--20 100HP (75KW)Part Number 02250075-- 727eSullair CorporationAIR COMPRESSORINDUSTRIALSTANDARD AND 24 KTOPERATOR SMANUAL ANDPARTS LISTKEEP FORFUTUREREFERENCEAIR CARESEMINAR TRAININGS ullair Air Care Seminars are 3--day courses that provide hands--on instructionin the proper operation, maintenance and service of Sullair seminars on INDUSTRIAL compressors and COMPRESSOR electricalsystems are presented at regular intervals throughout the year at a dedicatedtraining facility at Sullair s corporate headquarters in Michigan City, includes discussion of the function and installation of Sullair serviceparts, troubleshooting of the most common problems, and actual equipmentoperation.

LS--20 100HP (75KW) Part Number 02250075--727 eSullair Corporation AIR COMPRESSOR INDUSTRIAL STANDARD AND 24KT OPERATOR’S MANUALAND PARTS LIST KEEP FOR

Tags:

  Industrial

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of INDUSTRIAL AIR COMPRESSOR

1 LS--20 100HP (75KW)Part Number 02250075-- 727eSullair CorporationAIR COMPRESSORINDUSTRIALSTANDARD AND 24 KTOPERATOR SMANUAL ANDPARTS LISTKEEP FORFUTUREREFERENCEAIR CARESEMINAR TRAININGS ullair Air Care Seminars are 3--day courses that provide hands--on instructionin the proper operation, maintenance and service of Sullair seminars on INDUSTRIAL compressors and COMPRESSOR electricalsystems are presented at regular intervals throughout the year at a dedicatedtraining facility at Sullair s corporate headquarters in Michigan City, includes discussion of the function and installation of Sullair serviceparts, troubleshooting of the most common problems, and actual equipmentoperation.

2 The seminars are recommended for maintenance and detailed course outlines, schedule and cost information contact:Sullair Corporate Training Department1--888--SULLAIR or 219--879--5451 (ext. 5363)-- O r W r i t e --Sullair Corporation3700 E. Michigan City, IN 46360 Attn: Service Training DepartmentTABLE OF CONTENTSS ection PERSONAL PROTECTIVE PRESSURE FIRE AND MOVING HOT SURFACES, SHARP EDGES AND SHARP TOXIC AND IRRITATING ELECTRICAL ENTRAPMENTS ection MOUNTING OF COMPRESSOR VENTILATION AND SERVICE AIR SHAFT COUPLING FLUID LEVEL MOTOR ROTATION ELECTRICAL PREPARATIONS ection TABLE OF LUBRICATION GUIDE -- STANDARD LUBRICATION GUIDE -- 24KT LUBRICATION GUIDE--OPTIONAL FLUIDS ection 4 SUPERVISOR BASIC KEYPAD -- ALL STATUS LAMP INDICATORS-- ALL MODELSS ection DESCRIPTION OF SULLAIR COMPRESSOR UNIT,FUNCTIONAL COMPRESSOR COOLING AND LUBRICATIONSYSTEM.

3 FUNCTIONAL DESCRIPTIONTABLE OF CONTENTS(CONTINUED)Section 5 COMPRESSORPageSYSTEMS(cont.) COMPRESSOR DISCHARGE SYSTEM,FUNCTIONAL CONTROL SYSTEM, FUNCTIONAL AIR INLET SYSTEM, FUNCTIONAL DESCRIPTIONS ection PURPOSE OF SUPERVISOR II OPERATING PARAMETERS -- DELUXE PARAMETER OPERATING THE PURPOSE OF SUPERVISOR II OUTPUT MOTOR ROTATION INITIAL SHUTDOWN SUBSEQUENT START--UP SHUTDOWN PROCEDURES ection DAILY MAINTENANCE AFTER INITIAL 50 HOURSOF MAINTENANCE EVERY1000 HOURS OF PARTS REPLACEMENT AND ADJUSTMENTPROCEDURES29 AIR FILTER MAINTENANCE30 FLUID FILTER MAINTENANCE30 SEPARATOR ELEMENT MAINTENANCE31 SHAFT COUPLING MAINTENANCES ection CALIBRATIONTABLE OF CONTENTS(CONTINUED)

4 Section 9 PagePARTS PROCEDURE FOR ORDERING RECOMMENDED SPARE PARTS FRAME, MOTOR, COMPRESSOR AND AIR INLET COMPRESSOR LUBRICATION SYSTEM (AIR--COOLED) COMPRESSOR LUBRICATION SYSTEM WITHSPIRAL VALVE (AIR--COOLED) COMPRESSOR LUBRICATION SYSTEM (WATER--COOLED) COMPRESSOR LUBRICATION SYSTEM WITHSPIRAL VALVE (WATER--COOLED) COMPRESSOR COOLER ASSEMBLY (AIR--COOLED) COMPRESSOR WATER SYSTEM (WATER--COOLED) COMPRESSOR DISCHARGE SYSTEM (AIR--COOLED) COMPRESSOR DISCHARGE SYSTEM (WATER--COOLED) ELECTRICAL CONTROL SYSTEM (AIR--COOLED) ELECTRICAL CONTROL SYSTEM (WATER--COOLED) UNIT MOTOR ENCLOSURE ASSEMBLY (AIR--COOLED) ENCLOSURE ASSEMBLY (WATER--COOLED) DECAL WIRING DIAGRAM LS--20 WIRING DIAGRAM WYE--DELTA WIRING DIAGRAM DELUXE WIRING DIAGRAM WYE--DELTA DELUXENOTESS ection GENERALS ullair Corporation and its subsidiaries design andmanufacture all of their products so they can be op-erated safely.

5 However, the responsibility for safeoperation rests with those who use and maintainthese products. The following safety precautionsare offered as a guide which, if conscientiously fol-lowed, will minimize the possibility of accidentsthroughout the useful life of this COMPRESSOR should be operated only by thosewho have been trained and delegated to do so, andwho have read and understood this Operator sManual. Failure to follow the instructions, proce-dures and safety precautions in this manual can re-sult inaccidents andinjuries. Readthis manualpriorto the COMPRESSOR unless it is safe to NOTattempt tooperatethecompressor witha known unsafe condition. Tag the COMPRESSOR andrender it inoperative by disconnecting and lockingout all power at source or otherwise disabling itsprimemover, soothers whomay not know of the un-safe condition, cannot attempt to operate it until thecondition is , use and operate the COMPRESSOR only in fullcompliance with all pertinent regulations and all ap-plicable Federal, State, and Local codes, standardsand NOTmodify the COMPRESSOR and/or controls inany way except with written factory not specifically applicable to all types of com-pressors with all types of prime movers.

6 Most of theprecautionary statements contained herein are ap-plicable to most compressors and the concepts be-hind these statements are generally applicable PERSONAL PROTECTIVE EQUIPMENTP rior to installing or operating the COMPRESSOR , own-ers, employers and users should become familiarwith, and comply with, all applicable regulations andany applicable Federal, State and Local codes,standards, and regulations relative to personal pro-tective equipment, such as eye and face protectiveequipment, respiratory protective equipment,equipment intended to protect the extremities, pro-tective clothing, protective shields and barriers andelectrical protective equipment, as well as noise ex-posure administrative and/or engineering controlsand/or personal hearing protective PRESSURE anappropriateflow--limiting valvebetweenthe service air outlet and the shut--off (throttle)valve, either at the COMPRESSOR or at any other pointalong the air line, when an air hose exceeding 1/2 (13mm) inside diameter is to be connected to theshut--off (throttle)

7 Valve, to reduce pressure in caseof hose failure, per all applicable Federal, State andLocal codes, standards and thehose is to beused tosupply amanifold,install an additional appropriate flow--limiting valvebetween the manifold and each air hose exceeding1/2 (13mm) inside diameter that is to be connectedto the manifold to reduce pressure in case of an appropriate flow--limiting valve at thebeginningof eachadditional 75feet (23m) of hoseinruns of air hoseexceeding 1/2 (13mm) insidediam-eter to reduce pressure in case of hose valves are listed by pipe size andrated CFM. Select appropriate valves accordingly,in accordance with their manufacturer s DO NOTuse air tools that are rated below themaximum rating of the COMPRESSOR .

8 Select air tools,air hoses, pipes, valves, filters, and other fittings NOTexceed manufacturer s ratedsafe operating pressures for these all hose connections by wire, chain or oth-er suitable retaining devices to prevent tools or hoseends from being accidentally disconnected and fluid filler cap only whencompressorisnotrunning and is not down thecompressor and bleed the sump (receiver) to zerointernal pressure before removing the all internal pressure prior to opening anyline, fitting, hose, valve, drain plug, connection orother component, such as filters and line oilers, andbefore attempting to refill optional air line anti--icersystems with antifreeze personnel out of line with and away from thedischarge opening of hoses or tools or other pointsof compressed air air at pressures less than30 psig( bar) forcleaning purposes, and then only with effective chipguarding and personal protective DO NOTengage in horseplay with air hoses asdeath or serious injury may DO NOTtamper with sump and unit (if provided)relief valves.

9 Check the relief valve as recom-mended in the Maintenance Section of this manualor at a minimum of at least weekly to make sure it isnot blocked, clogged, obstructed or otherwise NOTchange the factory settingof there-lief the COMPRESSOR is installed in an enclosedarea, it is necessary to vent the relief valve to theoutside of the structure or to an area of FIRE AND EXPLOSIONWARNING!When installing a Base Load Transfer (BLT) Sys-tem, remove jumpers between 16--17 & 18--19(Dual Control Compressors) so the other com-pressor does not backfeed defeating the shut-down up spills of lubricant or other combustiblesubstances immediately, if such spills off thecompressor andallow it tocool.

10 Thenkeep sparks, flames and other sources of ignitionaway andDO NOTpermit smoking in the vicinitywhen checking or adding lubricant or when refillingair line anti--icer systems with NOTpermit fluids, including air line anti--icersystem antifreeze compound or fluid film to accu-mulate on, under, or around acoustical material, oron any external surfaces of the air COMPRESSOR or oninternal surfaces of the enclosure. Wipe down usingan aqueous INDUSTRIAL cleaner or steam--clean as re-quired. If necessary, remove acoustical material,clean all surfaces and thenreplace acoustical mate-rial. Any acoustical material with a protective cover-ing that has been torn or punctured should be re-placed immediately to prevent accumulation of liq-uids or fluid film within the solvents for cleaning and lock out all power at source priorto attempting any repairs or cleaning of the com-pressor or of the inside of the enclosure, if electrical wiring, including all terminals andpressureconnectors ingoodcondition.


Related search queries