Industrial fire ProtectionIndustrial fire ProtectionMONARCH Pre-EngineeredDry chemical SystemThe MONARCH System is anindustrial-strength leader forthe following applications:Vehicle and Industrial Paint Spray BoothsOpen Faced Industrial Paint Spray BoothsGeneral Industrial Total Flooding General Industrial Local ApplicationClose attention to product performance andcustomer satisfaction has fired up somecommercial-sized advantages with theMONARCH Pre-Engineered DryChemical After-Sale Service and Technical SupportUnbeatable 8 by 12 ft. ( x )Screening CoverageOverhead Protection up to 20 ft.

Approvals and Standards Underwriters Laboratories, Inc. (UL) Underwriters Laboratories of Canada (ULC) NFPA Standard 17:Dry Chemical Extinguishing Systems

Tags:

  Industrial, Protection, Chemical, Fire, Extinguishing, Industrial fire protection, Chemical extinguishing

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Industrial Fire Protection - PYRO-CHEM Home

1 Industrial fire ProtectionIndustrial fire ProtectionMONARCH Pre-EngineeredDry chemical SystemThe MONARCH System is anindustrial-strength leader forthe following applications:Vehicle and Industrial Paint Spray BoothsOpen Faced Industrial Paint Spray BoothsGeneral Industrial Total Flooding General Industrial Local ApplicationClose attention to product performance andcustomer satisfaction has fired up somecommercial-sized advantages with theMONARCH Pre-Engineered DryChemical After-Sale Service and Technical SupportUnbeatable 8 by 12 ft. ( x )Screening CoverageOverhead Protection up to 20 ft.

2 ( )-Ideal for Truck Booths Side-Wall Nozzle Stacking to Unlimited HeightsSide-Wall Nozzle Protection for Full-FilteredStandard Vehicle BoothSuperior Duct and Plenum CoverageExtended Nozzle Coverage Means Fewer Tanksand Lower CostTanks Can Be Distributed around Protected AreaBalanced Piping FlexibilityEasy Installation Few Piping LimitationsMONARCH systems offer breakthroughtechnology in the industry s most flexible andeffective fire suppression system. The fireextinguishing agent is dry chemical which,pound for pound, suppresses more fire than anyother Industrial Systems have been testedand approved in accordance with UL andapplicable NFPA standards.

3 Pyro-Chemauthorized distributors have been extensivelytrained in system design, installationand the MONARCHPre-Engineered Dry chemical Systempart of your fire Protection and automotivecommercial environments can developa truckload of potential fire material storage areas andcommercial paint spray booths today involvehighly flammable liquids, creating anenvironment in which fire is always a can build up, chemicals can leak orspill. Add an ignition source and it becomes apotentially devastating combination. If fireoccurs, systems must be shut off and alarmsand other electrical devices must be MONARCH Pre-Engineered Dry ChemicalSystem can protect a diverse range of hazardareas and perform all the necessaryauxiliary functions.

4 Approvals and StandardsUnderwriters Laboratories, Inc. (UL)Underwriters Laboratories of Canada(ULC)NFPA Standard 17:Dry ChemicalExtinguishing SystemsNFPA Standard 33:Spray ApplicationUsing Flammable and CombustibleMaterialsNFPA Standard 34:Dipping and CoatingProcesses Using Flammable orCombustible Liquids The MONARCH System delivers asurplus of cost effective fireprotection detection and actuation controlsprovide 24-hour manual actuation system allowsimmediate actuation at the first sign of fireand provides backup to the automaticdetection most effective fire - extinguishing agent inthe industry.

5 Dry chemical suppresses morefire than any other rated steel tanksready for release in the event of a gauge on the agent tank allowsvisual inspection of system assembled and 100% testedmechanical control head provides reliableoperation of the input and output piping configurations allow for astreamlined design that will not interferewith space elements of the system such as thecontrol head, cylinder valve assembly andgas shut-off valve are fully assembled and100% inspected by nozzle caps help prevent contamination and blockage by paint orother commercial byproducts that can inhibitthe proper discharge of extinguishing agent.

6 The MONARCH system is available in avariety of sizes economically suited to fitspecific needs, designed with the flexibilityto accommodate changes to assembly linelayout or work area expansion. Nozzles and Caps --Specifically designedto give maximumprotection for variousapplications withinspecific hazard , Brackets andFusible Links --Avariety of temperaturerated heat detectors sensea fire in the protected areaand immediately signalthe control unit. Alarm Bell --Among other warnings, the control unit soundsthe alarm bell, alerting workers to clear the Tanks --Available in a number of sizes addingflexibility to design coverage Heads --Easy to install.

7 Multiple designs activatedby a fusible link, thermal detector ormanual pull station. Common among allPyro-Chem pre-engineered systems. Pull Station --Allows manual actuation at asafe distance from the Delay --Factory presetmechanical timedelay. Retards systemdischarge for 10-20seconds to allow forexhaust 10 and200 Cylinders --Allows for actuation of10 to 20 cylinderssimultaneously.