Example: stock market

Industrial Fluorescent - Cooper Industries

Industrial FluorescentEnergy SolutionsFLUORESCENT HIGH BAYSFLUORESCENT LOW BAYSCOMPLEX ENVIRONMENT1 Our world is increasingly recognizing the importance ofenvironmental sustainability and efficiency in buildingdesign. While cost containment and productivity gainsare universal demands, increasing lighting efficiencyrequires an understanding of the role lighting plays in thebusiness Lighting has always been at the forefront inadopting and adapting to the latest advancements inlighting technology.

Thermal Performance and Light Output Unlike HID lamps, T5 and T8 lamps reach optimal light output in specific temperature ranges. In partially or unconditioned spaces, temperatures

Tags:

  Industrial, Industreis, Cooper industries, Cooper, Fluorescent, Industrial fluorescent

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Industrial Fluorescent - Cooper Industries

1 Industrial FluorescentEnergy SolutionsFLUORESCENT HIGH BAYSFLUORESCENT LOW BAYSCOMPLEX ENVIRONMENT1 Our world is increasingly recognizing the importance ofenvironmental sustainability and efficiency in buildingdesign. While cost containment and productivity gainsare universal demands, increasing lighting efficiencyrequires an understanding of the role lighting plays in thebusiness Lighting has always been at the forefront inadopting and adapting to the latest advancements inlighting technology.

2 Over the years, businesses andcommunities have benefitted from partnering withCooper Lighting to improve energy efficiency and reducecosts while protecting and enriching the those of you considering a more efficient lightingupgrade, this brochure presents a variety of products andprovides tips on how to make your retrofit project asuccess. A Cooper Lighting energy efficient lightingupgrade will reduce your utility bill; improve employeemorale and productivity; andhelp protect and preservethe Fluorescent Advantage.

3 Pg. 3 Energy Savings ..pg. 3 Lamp Life and Lumen Maintenance ..pg. 3 Uniformity ..pg. 3 Instant On/Off and Occupancy Sensors ..pg. 4T8 or T5HO? ..pg. 4 Thermal Performance and Light Output ..pg. 5 Visible Light and the Scotopic/Photopic (S/P) Ratio ..pg. 6 Environmentally Friendly ..pg. 6 Product Index ..pgs. 7-8 HBI ..pgs. 9-14 HBE ..pgs. 15-20I5/I8 ..pgs. 21-24 HBL ..pgs. 25-30 MBF ..pgs. 31-322 HBG ..pgs. 33-34 HBHD ..pgs. 35-36 HBHT ..pgs. 37-38 ARCTIC BAY - ABI ..pgs. 39-40VT4 ..pgs. 41-42VT3 ..pgs. 43-44VT1.

4 Pgs. 45-46 Lamp Options ..pgs. 47 Emergency Options Matrix ..pgs. 48F-Bay Mounting Accessories Matrix ..pgs. 48 Packaging Options Matrix ..pgs. 48 Mounting Accessories ..pgs. 49-50 Occupancy Sensors ..pgs. 51 Power Connections ..pgs. 52I5/I8 Lens, Door Frames and Wireguards ..pgs. 53 HBI, HBL and HBE Lens, Door Frames and Wireguards ..pgs. 54 Table of Contents455400 Watt High Bay F-BayHBI-654 T5 HOF-BayHBI-632F-Bay I5-454 T5HO $ $ $ $ $ $ $ $ $ $ $ $ ENERGY SAVINGS KWH $ $ $ $ (based on 4000 hrs.) 5004003002001000 The Fluorescent AdvantageThe most popular and productive lighting upgrades today involve replacing outdated Fluorescent or HID (High Intensity Discharge)

5 Lighting Performance Fluorescent lighting systems from Cooper Lighting utilize the latest technologies and design platforms to provide dramaticenergy savings and superior fluorescentsystems improve lightinguniformity comparedwith HID SavingsCooper Lighting Fluorescent high bays offer dramatic energy savings opportunitiesover HID Lighting systems and providequick Initial 10000 15000 20000 25000 35000 Lamp Life & Lumen Maintenance LIGHT OUTPUT HOURS 400 Watt High Bay T5 HO 6-Lamp T8 HO Ballast 6-Lamp T5 HO 4-Lamp End of Lamp Life Dimensions 160 x 10 400W MH 4-Lamp 54W 6-Lamp 32 WFixture Type High Bay T5HO I5 Series HBI SeriesNumber of Fixtures 13 13 13 Initial Lumens per Lamp 36000 4400 2850 Initial Lumens per Fixture 36000 17600 17100 Light Loss Factor Wattage 455 229 221 Maintained Average FC 43 33 43 Max FC 47 38 48 Min FC 37 27 36 Average to Min to Min Average FC 22 15 20 Max FC 35 23 30 Min FC

6 12 9 11 Average to Min WattHigh-BayMetaluxHBI-632 T8 Lamp Life and Lumen MaintenanceT5 and T8 Fluorescent systems providebetter maintained light levels over magneticHID lighting systems with twice the lamplife. Multiple lamped Fluorescent luminairesreduce the need for immediate Fluorescent systems, the other lampswill stay illuminated when individual or T5HO?If your facility currently has T8 or T5HO lamps installed, the decision on lamp choice may be easy and allow for inventory lamp types provide excellent performance but the attributes of each lamp type vary.

7 Selection of lamp type is an importantconsideration. The following operating characteristics should be considered when making the selection:T8 Lighting SystemsT5HO Lighting SystemsFirst CostsLamp Replacement CostsLumens Per WattApplication HeightsAmbient EnvironmentsFrequency of StartsBallasts Light LevelFlexibilityLuminaires in ComparisonFluorescent High Bay System ComparisonSimilar within ranges to T5 systems with lower lamp costs offsetby larger luminaire cost lamps offset with higher quantityfor similar light outputSimilar within ranges to T8 systems with higher lamp costs offsetby smaller luminaire cost lamps offset with lower required

8 Quantityfor similar light output9187 Suitable in wide ranges. Lower lumen output T8 s are idealfor lower mounting heights below 15' while less ideal atmounting heights above 30'.Suitable in wide ranges. Higher output T5HO lamps are ideal forhigher mounting heights where higher lumen values allow for areduced number of on luminaire. T8 systems achieve maximum outputin 78 F (25 C) ambient environments. Starting temperatureranges as low as 0 F (-18 C) dependent on manufacturer oflamp, ballast, age of lamps and luminaire designDependent on luminaire.

9 T5HO systems achieve maximum outputin 95 F (35 C) ambient environments. Starting temperatureranges as low as -20 F (-29 C) dependent on manufacturer oflamps, ballast, age of lamps and luminaire designStandard T8 systems with instant start ballasts and frequenton/off cycles can dramatically reduce lamp life. ProgramStart T8 ballasts should be specified when used with highoccurrence of on/off Program Start ballast systems are ideal for frequent startsand use with occupancy in multiple light output ranges from 71% to 115% ofrated lamp life output, allowing for flexibility in applicationwithout changing lamp offered in fixed Light output HBI632 using (6) 80+CRI T8 lamps withHigh Output I5455 using (4) T5HO 80+CRI Lumens:20,000 Wattage:221 Net Lumens:20,000 Wattage.

10 22940000 35000 30000 25000 20000 15000 10000 5000 0 15 min. 30 min. 1 hr. 3 hr. 12 hr. Continuous START FREQUENCY Lamp Life Comparison Program Start Ballasts Instant Start Ballasts HRS/LAMP LIFE Instant On/Off and Occupancy SensorsFluorescent systems can be used with occupancy sensors to provide instant on/off capabilities to maximize energy using T8 lamps and occupancy sensors, Cooper Lighting Industrial Fluorescent luminaires use only softer starting program start ballasts to minimize damage to the lamp. Under frequent on/off cycles, program start ballasts will dramatically extend lamp life over instant start ballasts.


Related search queries