DESCRIPTIONThe Trerice 220 TSTP ressure Transmitter is the ideal choice for demanding Industrial , test & measurement andprocess control applications. Thanks to the stainless steel/thin-film sensor element being directly welded to the process connection, the 220 TST requires no internal transmission media or seals insuring a high degree of reliability and stability. Stainless steel wetted parts provide long-term durability even in the harshest environments. In addition, the modular design of the 220 TST Pressure Transmitter allows for a wide variety of electrical connections, output signals and process connections to be specified to meet the requirements of any Pressure TransmitterModel 220 TST12950 W.

DESCRIPTION The TRERICE 220TST Pressure Transmitter is the ideal choice for demanding industrial, test & measurement and process control applications.

Tags:

  Transmitter, Trerice

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Industrial Pressure Transmitter - H.O. Trerice …

1 DESCRIPTIONThe Trerice 220 TSTP ressure Transmitter is the ideal choice for demanding Industrial , test & measurement andprocess control applications. Thanks to the stainless steel/thin-film sensor element being directly welded to the process connection, the 220 TST requires no internal transmission media or seals insuring a high degree of reliability and stability. Stainless steel wetted parts provide long-term durability even in the harshest environments. In addition, the modular design of the 220 TST Pressure Transmitter allows for a wide variety of electrical connections, output signals and process connections to be specified to meet the requirements of any Pressure TransmitterModel 220 TST12950 W.

2 Eight Mile Road Oak Park MI 48237-3288 Tel: Fax: : E-mail: Ranges from 30 Hg to 0 thru 0 to 20,000 psi 4-20mA and 0-10 Vdc Standard Industrial Output Signals Fully welded "Dry Measuring Cell", requires no internal transmission fluid or seals 17-4 PH stainless steel wetted parts 304 stainless steel body Industry standard electrical connections including DIN 175301-803A, C and Shielded Cable Highly flexible modular design Protection Class IP65/NEMA 4X (Shielded Cable Connection IP67/NEMA 6) Applications Industrial Environments Process Automation Hydraulic Systems Pump System Control Testing Technologies Commercial / HVAC212950 W.

3 Eight Mile Road, Oak Park, Michigan 48237 Toll Free:1-888-873-7423 Fax:1-248-399-7246 Standard TransmitterSensor ElementStainless steel membrane / poly-Si on SiO2thin film resistorsProcess Connection1/4 NPT maleMaterials of ConstructionHousing: 304 stainless steel Wetted Parts: 17-4 PH stainless steel Full Scale (Terminal Point Method) / Full Scale (BFSL)Includes: Non-Linearity, Hysteresis and Temperature RangesMedium: -40/+257 F (-40/+125 C)Ambient: -40/+221 F (-40/+105 C)Temperature Error BandTemperature compensated to within 1% between -4 F and 185 F(-20 C and 85 C).

4 Best accuracy of < at 77 F (25 C). Humidity95% RH Non-condensing0-100% RH with Shielded Cable Connection (E3)Electrical Connection90 Angle Standard Connector / DIN 175301-803 (A)90 Angle Mini Connector / DIN 175301-803 (C)Shielded Cable (3 Ft)Output Signal4-20mA (2 wire) and 0-10 Vdc (3 wire) Overpressure LimitRanges 5000 psi x FSBurst Pressure > 3 x FS10,000-20,000 psi x FSBurst Pressure > x FSResponse Time (10-90%)< 1 msPower SupplyOutput Signal:MinimumMaximumRecommended4-20mA:1 0 Vdc32 Vdc24 Vdc0-10 Vdc:12 Vdc32 Vdc24 VdcLoad Resistance4-20 mA.

5 Vdc Supply-10 Vdc = Ohm resistance (maximum)0-10 Vdc: >5 kOhm (minimum)Circuit protectionProtected against reverse polarity and short circuitsCE conformity EC Directive 89/336/EWGI ngress Protection Rating90 Angle Connector: IP65 / NEMA 4 XShielded Cable: IP67 / NEMA 6 Approx. Shipping lbs ( )ModelProcess AccuracyUnits of Range CodeElectrical ConnectionOutput SignalConnectionMeasure220 TST 021 FS ApsiSee StandardE1 DIN 175301-803 (A) std 34-20mA (2-wire)( BFSL)RangesE2 DIN 175301-803 (C) mini 20-10 Vdc (3-wire)E3 Shielded Cable (3 Feet)Other electrical connections, output signals and process connections available.

6 Please consult factory. How To Order Example:220 TST 02 C A 0/100 E1 3 Model 220 TSTI ndustrial Pressure TransmitterIndustrial Pressure Transmitter12950 W. Eight Mile Road, Oak Park, Michigan 48237 Toll Free:1-888-873-7423 Fax:1-248-399-7246 & Dimensions3E1 90 Angle std ConnectorE290 Angle mini ConnectorE3 Shielded CableDIN 175301-803 (A)DIN 175301-803 (C)(3 Feet)Range CodeSpecific Range (psi)Overpressure LimitBurst Pressure30/030"Hg to 023 psi45 psi 30/1530"Hg to 15 psi45 psi90 psi30/3030"Hg to 30 psi68 psi135 psi30/6030"Hg to 60 psi113 psi225 psi30/10030"Hg to 100 psi173 psi345 psi30/15030"Hg to 150 psi248 psi495 psi30/30030"Hg to 300 psi473 psi945 psi0/150 to 15 psi 23 psi45 psi0/300 to 30 psi45 psi90 psi0/600 to 60 psi 90 psi180 psi0/1000 to 100 psi150 psi300 psi0/1600 to 160 psi240 psi480 psi0/2000 to 200 psi300 psi600 psi0/3000 to 300 psi450 psi900 psi0/4000 to 400 psi600 psi1200 psi0/6000 to 600 psi900 psi1800 psi0/10000 to 1000

7 Psi1500 psi3000 psi0/15000 to 1500 psi2250 psi4500 psi0/20000 to 2000 psi3000 psi6000 psi0/30000 to 3000 psi4500 psi9000 psi0/50000 to 5000 psi7500 psi15000 psi0/100000 to 10000 psi12000 psi15000 psi0/150000 to 15000 psi18000 psi22500 psi0/200000 to 20000 psi24000 psi30000 psiStandard RangesModel 220 TSTI ndustrial Pressure TransmitterIndustrial Pressure [22] Hex1/4 -18 [14] [22] [22] Hex1/4 -18 [28] [71] [22] 1/4 -18 [14] [22] [14] [22] [83] [34] [36] [57] Trerice CompanyFrom its start in 1923 in Detroit, the Trerice Company has remained true to the commitment of itsfounder - QUALITY in both PRODUCT and SERVICE.

8 This commitment has solidly established Trerice as a worldwide leader in the manufacture of specialized engineered products for Industrial temperatureand Pressure measurement and your requirements demand quality instrumentation and controls, the broad line of Trerice products are ready for your application. Contact us today for detailed information on your particularareas of W. Eight Mile Road Oak Park MI 48237-3288 Wire Circuits(4 20mA)3- WireCircuits(0-10 Vdc)DIN 175301-803 (A)Shielded Cable DIN 175301-803 (C) 2016 Copyright Trerice WireCircuits(0-10 Vdc)2- WireCircuits(4 20mA)Electrical Connections Wiring DiagramIndustrial Pressure TransmitterModel 220 TSTM odel 220 TSTI ndustrial Pressure Transmitter