Example: tourism industry

Industrial Securit Framework ASTM F1083 …

Industrial / Security Framework astm F1083 Schedule 40 PipeSubmittal Data SheetWheatland Tube 700 South Dock Street Sharon, PA 16146P | F | | :ENGINEER:LOCATIONS:CONTRACTOR:SPECIFICA TION REFERENCE:DATE:SYSTEM TYPE:COMMENTS:SUBMITTAL INFORMATION Scope This submittal data sheet covers 2 grades of astm F1083 hot-dipped galvanized schedule 40 welded steel pipe for fence structures, Regular Grade and High Strength Grade. The accompanying tables show the different Grades have the same dimensions, wall thickness, weight per linear foot, galvanized coating and tolerances. The Grade signifies the yield strength of the schedule 40 GalvanizedPipe shall be coated inside and out by the hot-dip process.

Wheatland Tube tr 146 P .343.012 F 24.346.7 o@wheatland.c tland.com Fence Industry Decimal OD Equivalent Pipe Wall Thickness

Tags:

  Industrial, Astm, Framework, Fence, Industrial securit framework astm f1083, Securit, F1083

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Industrial Securit Framework ASTM F1083 …

1 Industrial / Security Framework astm F1083 Schedule 40 PipeSubmittal Data SheetWheatland Tube 700 South Dock Street Sharon, PA 16146P | F | | :ENGINEER:LOCATIONS:CONTRACTOR:SPECIFICA TION REFERENCE:DATE:SYSTEM TYPE:COMMENTS:SUBMITTAL INFORMATION Scope This submittal data sheet covers 2 grades of astm F1083 hot-dipped galvanized schedule 40 welded steel pipe for fence structures, Regular Grade and High Strength Grade. The accompanying tables show the different Grades have the same dimensions, wall thickness, weight per linear foot, galvanized coating and tolerances. The Grade signifies the yield strength of the schedule 40 GalvanizedPipe shall be coated inside and out by the hot-dip process.

2 The average weight of zinc coating shall be not less than oz / ft2 of the outside surface and oz / ft2 of the inside surface. A oz / ft2 zinc coating weight is available upon request. A conversion coating is also applied to the interior and exterior surfaces to protect against corrosion and white s zinc coating is virtually lead FinishEnd finish shall be plain end square and rails shall be one piece free of welded sections. Tensile RequirementsTensile Strength, min. 48,000 psi Yield Strength, min. 30,000 psiHigh Strength Grade Tensile Strength, min. 60,000 psi High Strength Grade Yield Strength, min.

3 50,000 psiPermissible Variations in Wall ThicknessMinimum wall thickness at any point shall not be more than under nominal wall thickness Variations in Outside " and under + " " " and over 1%Wheatland offers the most extensive size range of any fence Framework manufacturer. Permissible Variations in Weight Per FootPipe shall not vary more than 10% from the standard MarkingEach length of pipe " and larger is continuously stenciled as follows:Wheatland, USA, Size, Schedule 40, astm F1083 , oz. or oz., Grade, Length, Run #, and DateBar Coding is acceptable as a supplementary identification method.

4 Wheatland F1083 Schedule 40 Galvanized Pipe meets or exceeds the following specifications: American Association of State Highway and Transportation Officials AASHTO M181 Grade 1 Federal specifications RR-F-191 / 2E and RR-F-191 / 3E Army Corps of Engineers UFGS-32 31 13 Department of the Navy Department of Transportation Federal Aviation Administration AC 150 / 5370-10 Item 162 Department of Justice Federal Bureau of Prisons astm Specification F1043 Group 1A Standard Specification for Strength and Protective Coatings American Institute of Architects (AIA) MasterSpec astm Specification F1083 Wheatland Tube 700 South Dock Street Sharon, PA 16146P | F | | Industry Decimal OD Equivalent Pipe Wall Thickness Weight Section Modulus x Min.

5 YieldStrength = Max Bending Moment Calculated Load (lbs.) 10' Free Supported Cantilever OD in.(mm) in. (mm) lb. / ft.(kg / m) (mm3) x psi (MPa) = lb. / in. 4' 6' 1 3/8" 30000205= 398513383551 5/8" 30000205= 7038235147981 7/8" 30000205= 97863262041362 3/8" 30000205= 168195613502342 7/8" 30000205= 3192110646654433 1/2" 30000205= 51723172410787184" 30000205= 71816239414969974 1/2" 30000205= 96435321420091399*5 9/16" 35000240= 190789635939752650*6 5/8" 35000240= 297353991261954130*8 5/8" 35000240= 58831919610122578171 astm F1083 Regular Grade 30,000 PSI Yield Schedule 40 Pipe Dimensions and Strength Characteristics*Manufactured to astm A53 specifications.

6 Exceeds F1083 Industry Decimal OD Equivalent Pipe Wall Thickness Weight Section Modulus x Min. YieldStrength = Max Bending Moment Calculated Load (lbs.) 10' Free Supported Cantilever OD in. (mm) in. (mm) lb. / ft.(kg / m) (mm3) x psi (MPa) = lb. / in. 6'15' 1 5/8" 50000345= 11730392163651 7/8" 50000345= 1631054322791 2 3/8" 50000345= 280309353891562 7/8" 50000345= 5320017737392963 1/2" 50000345= 86205287311974794" 50000345= 119695399016626654 1/2" 50000345= 160725535722328935 9/16" 50000345= 2725559085378515146 5/8" 50000345= 42479014160590023608 5/8" 50000345= 84045528015116734669 astm F1083 High Strength Grade 50,000 PSI Yield Schedule 40 Pipe Dimensions and Strength CharacteristicsPlease contact fence Sales for mill run schedule.

7 Minimum order quantities may be , illustrated material and descriptions are accurate as known at time of publication and are subject to change without notice.


Related search queries