Example: biology

Industrial Thermoregulation - findernet.com

IndustrialThermoregulationProducts for panels and enclosures7T Series - Thermo-Hygrostat and Thermostats7F Series - Filter Fans7H Series - Panel HeatersSELECTION GUIDEP erfect climate inside panelsClimate controlHigh precisionCompact sizeA range of products dedicated to maintaining constant temperature in control panels and and Thermostats 7T SeriesEnsures performance of components and instrumentation in control panels and enclosures, and can prolong product Fans7F SeriesNew filter fan range to ventilate and safeguard against high Heaters7H SeriesPrevents the formation of condensation and ensuresthe optimum temperature within electrical power from 50 W to 400 Thermo-HygrostatDrying kilnsIndustrial refrigerationRoad / tunnel lightingIndustrial furnaces and ovensAutomatic car-washesPanels for electrical distributionControl panelsForced-air ventilators7T SeriesPanel Thermo-Hygrostat and ThermostatsRH setRH13-14RH setRH13-14HT: RH > RHset OR Tamb > TsetPower is permanentely applied to the thermo-hygrostat.

SELECTION GUIDE. Perfect climate inside panels Climate control High precision Compact size ... Road / tunnel lighting Industrial furnaces and ovens Automatic car-washes Panels for electrical distribution Control panels Forced-air ventilators 7T Series Panel Thermo-Hygrostat and Thermostats

Tags:

  Guide, Road, Tunnel, Lighting, Tunnel lighting

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Industrial Thermoregulation - findernet.com

1 IndustrialThermoregulationProducts for panels and enclosures7T Series - Thermo-Hygrostat and Thermostats7F Series - Filter Fans7H Series - Panel HeatersSELECTION GUIDEP erfect climate inside panelsClimate controlHigh precisionCompact sizeA range of products dedicated to maintaining constant temperature in control panels and and Thermostats 7T SeriesEnsures performance of components and instrumentation in control panels and enclosures, and can prolong product Fans7F SeriesNew filter fan range to ventilate and safeguard against high Heaters7H SeriesPrevents the formation of condensation and ensuresthe optimum temperature within electrical power from 50 W to 400 Thermo-HygrostatDrying kilnsIndustrial refrigerationRoad / tunnel lightingIndustrial furnaces and ovensAutomatic car-washesPanels for electrical distributionControl panelsForced-air ventilators7T SeriesPanel Thermo-Hygrostat and ThermostatsRH setRH13-14RH setRH13-14HT: RH > RHset OR Tamb > TsetPower is permanentely applied to the thermo-hygrostat.

2 The contact 13-14 closes if the ambient humidity (RH) is > of set humidity (RHset) OR if the ambient temperature (Tamb) is > of set temperature (Tset).When contact is closed, LED is ONTH: RH > RHset OR Tamb < TsetThe contact 13-14 closes if the ambient humidity (RH) is > of set humidity (RHset) OR if the ambient temperature (Tamb) is < of set temperature (Tset).When contact is closed, LED is ONType Electronic control Small, compact size ( mm wide)1 NO 10 A - 250 V AC14 functionsNominal voltage V AC/DCTemperature ranges from +10 to +60 CHumidity range up to 90%LED status indication contact ONApprovals (according to type):HL: RH < RHsetThe contact 13-14 closes if the ambient humidity (RH) is < of set humidity (RHset).

3 When contact is closed, LED is ONHM: RH > RHsetThe contact 13-14 closes if the ambient humidity (RH) is > of set humidity (RHset).When contact is closed, LED is ON5 Ventilation control Should the panel temperature exceed the (maximum) set temperature then the contact will close to call for cooling. The contact will open when the temperature falls below this set : Blue DialTemperature ranges: 20 a +40 C 0 a +60 CType Direct switching of heater loads up to 2500 VAMinMaxPanel ThermostatsSmall, compact size ( mm wide)1 NC 10 A - 250 V AC1 Snap action thermostatic Bimetal sensorWide temperature setting rangeLong electrical life35 mm rail (EN 60715) mountApprovals (according to type):Heating controlShould the panel temperature fall below the (minimum) set temperature the contact will close to call for heat.

4 The contact will open when this set temperature is : Red DialTemperature ranges: 20 a +40 C 0 a +60 CType Direct switching of fans up to 130 W7F Seriesproducts7F SeriesproductsFilter FansEasily replaceable filter matMinimal depth within enclosure Air volume ( )m3/hTime-saving installation and maintenanceVery low acoustic noiseProtection category IP54 Approvals (according to type):7F SeriesFilter Fans and Exhaust FiltersDrying kilnsTextile machinesMachines for paper processingMachines for ceramicsWood-processing machinesPanels for electrical distributionControl panelsForced-air ventilatorsType voltage (120 or 230)V ACAir volume 24 m3/hRated power 13 WSize 1 Type voltage 24V DCAir volume 24 m3/hRated power WSize 1 Type voltage (120 or 230)V ACAir volume 55 m3/hRated power 22 WSize 2 Type voltage 24V DCAir volume 55 m3/hRated power 9 WSize 2 Type voltage (120 or 230)

5 V ACAir volume 100 m3/hRated power 22 WSize 3 Type voltage 24V DCAir volume 100 m3/hRated power 22 WSize 3 The size of the Exhaust Filter should match the size of the Filter Fan to achieve the best ventilation within the installation and maintenanceEasily replaceable filter matProtection category IP54 Approvals (according to type):Type Filter Fans Type 2 Type Filter Fans Type 3 Type Filter Fans Type 1 Exhaust FiltersMounting arrangement of Filter Fan and Exhaust FilterReplacement of Filter mat 7 Minimal depth within enclosure Air volume ( )m3/hVery low acoustic noiseProtection category IP54 Approvals (according to type):Type voltage (120 or 230)V ACAir volume 230 m3/hRated power 40 WSize 4 Type voltage 24 V DCAir volume 230 m3/hRated power 26 Size 4 Type voltage (120 or 230)V ACAir volume 370 m3/hRated power 70 WSize 4 Type voltage (120 or 230)V ACAir volume 500 m3/hRated power 70 WSize 5 Type voltage (120 or 230)

6 V ACAir volume 630 m3/hRated power 130 WSize 5 Drying kilnsTextile machinesMachines for paper processingMachines for ceramicsWood-processing machinesPanels for electrical distributionControl panelsForced-air ventilators7F SeriesFilter Fans and Exhaust FiltersFilter Fans9 The size of the Exhaust Filter should match the size of the Filter Fan to achieve the best ventilation within the depth within enclosureProtection category IP54 Approvals (according to type):Type Filter Fans Type or Type 4 Type Filter Fans Type or Type 5 Standard versionsEMC versionsReverse flow Size Size 4 Filter Fans - Available versionsStandard-Filter FanStandard-Exhaust FilterFilter 4 EMC-Filter FanEMC-Exhaust FilterFilter 4 ComponentsSize 1 Size 2 Size 3 Size 4 Size 5 Exhaust Filters7H SeriesPanel HeatersDrying kilnsHoists and cranesRoad / tunnel lightingPlastic moulding machinesAutomatic car-washesPanels for electrical distributionControl panelsForced-air ventilatorsType power 250 WFan assistedDimensions (w x h x d): x x 67 Type power 400 WFan assistedDimensions (w x h x d).

7 X x 67 Panel HeatersNominal voltage 230 V ACPTC resistor, self regulating heating systemFan assisted heatersFast wiring terminals Safe touchClip for 35 mm rail (EN 60715) mountApprovals (according to type) = L (heater)2 = N3 = L (fan)F = ANOTES eparate supply (L) terminals for the heater and the internal fan allow them to be powered , dependent on the specific situation, the installer might wish the heating element to be controlled by an upstream thermostat but require the fan to run continuously (although the latter will significantly reduce the product s life). voltage V AC/DCPTC self regulating heating systemScrew terminalsSafe touchClip for 35 mm rail (EN 60715) mountApprovals (according to type):Panel HeatersType power 150 WDimensions (w x h x d): 70 x 220 x 63 mmType power 25 WType Heater power 50 WDimensions (w x h x d): 41 x 125 x 41 mmType power 100 WDimensions (w x h x d): 70 x 140 x 63 mmDC - wiring diagramAC - wiring - October 2018 - Selection guide - Industrial Thermoregulation - Online updatesFinder in the worldDiscover the worldwide network at reserves the right to alter characteristics at any time without notice.

8 FINDER assumes no liability for damage to persons or property, caused as a result of the incorrect use or application of its products.