Example: stock market

Industry Cables - Prysmian Group

Industry CablesSpecial Cables for industrial applicationsGeneral CatalogueIndustry CablesSpecial Cables for industrial applicationsGeneral catalogueAs the worldwide leader in the cable Industry , Prysmian Group believes in the effective, efficient and sustainable supply of energy and information as a primary driver in the development of this in mind, we provide major global organisations in many industries with best-in-class cable solutions, based on state-of-the-art technology. Through two renowned commercial brands - Prysmian and Draka - based in almost 50 countries, we re constantly close to our customers, enabling them to further develop the world s energy and telecoms infrastructures, and achieve sustainable, profitable our energy business, we design, produce, distribute and install Cables and systems for the transmission and distribution of power at low, medium, high and extra-high telecoms, the Group is a leading manufacturer of all types of copper and fibre Cables , systems and accessories - covering voice, video and data on over 130 years experience and continuously investing in R&D, we apply excellence, u

Low voltage - welding cables page 33 H01N2-D / ARCOFLEX page 34 H01N2-E / FLEXIPREN page 36 Low voltage - heat resistant cables page 39 ... Insulation Vulcanized rubber compound, basis EPR, compound EI4 in accordance with EN 50363-1 ... Outer sheath synthetic rubber compound, compound EM2 in accordance with EN 50363-2-1

Tags:

  Cable, Voltage, Insulation, Synthetic

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Industry Cables - Prysmian Group

1 Industry CablesSpecial Cables for industrial applicationsGeneral CatalogueIndustry CablesSpecial Cables for industrial applicationsGeneral catalogueAs the worldwide leader in the cable Industry , Prysmian Group believes in the effective, efficient and sustainable supply of energy and information as a primary driver in the development of this in mind, we provide major global organisations in many industries with best-in-class cable solutions, based on state-of-the-art technology. Through two renowned commercial brands - Prysmian and Draka - based in almost 50 countries, we re constantly close to our customers, enabling them to further develop the world s energy and telecoms infrastructures, and achieve sustainable, profitable our energy business, we design, produce, distribute and install Cables and systems for the transmission and distribution of power at low, medium, high and extra-high telecoms, the Group is a leading manufacturer of all types of copper and fibre Cables , systems and accessories - covering voice, video and data on over 130 years experience and continuously investing in R&D, we apply excellence, understanding and integrity to everything we do.

2 Meeting and exceeding the precise needs of our customers across all continents, at the same time shaping the evolution of our the Future23 Industry cables4 IndexProduct DatasheetsLow voltage - rubber sheathed Cables page 9 H05RR-F / OZOFLEX page 10 H05RN-F / OZOFLEX page 12 H07RN-F / OZOFLEX page 14 Low voltage - rubber sheathed Cables halogen-free page 19 H07ZZ-F / halogen-free and low smoke page 20 Low voltage - PUR sheathed rubber Cables page 25 H05BQ-F / PUR cable page 26 H07BQ-F / PUR Singlesheath page 28 H07BQ-F / PUR Duosheath page 30 Low voltage - welding Cables page 33 H01N2-D / ARCOFLEX page 34 H01N2-E / FLEXIPREN page 36 Low voltage - heat resistant Cables page 39 SIA/SIAF 300/500 V / SINOTHERM(180) page 40 SIAF kV / SINOTHERM(180)

3 Page 42 H05SS-F / SINOTHERM(180) page 44 H07G-K / SINOTHERM(110) page 46 H07G-K UL3343 / Heat resistant single core cable page 48 H05GG-F / SINOTHERM(110) page 50 Medium voltage - special rubber Cables page 53 NSGAFOEU kV page 54 NSGAFOEU kV page 56 NSHXAFOE kV page 58 (N)3 GTMC11Y / FELTOFLEX PUR page 60 5 Industry cablesProduct DatasheetsWires/braids page 63 8Y 13 page 64 8Y 26 page 66 6Y 90 FEP AWG page 68 21X LS0H page 70 Y 671 UL1015 page 72 Motor Supply - EMC Cables page 75 2 XSLCY / PROTOFLEX EMC-FC kV page 76 3 GSEGCH / MS-SIENOPYR EMC-FC page 78 3 GSEGCY / MS-PROTOFLEX EMC-FC page 80 Water - Cables for waste water page 83 H07RN8-F / OZOFLEX (PLUS) page 84 S1BN8-F kV / TECWATER page 88 S1BC4N8-F / TECWATER EMC-FC page 92 NSSHOEU kV / PROTOMONT page 94 (N)TSWOEU / MS-TECWATER page 98 Water - cable for drinking water page 101 S07BB-F / HYDROFIRM(T) page 102 S07 BBH2-F / HYDROFIRM(T)

4 Page 106 S1BB-F / HYDROFIRM(T) page 108 S1 BBH2-F / HYDROFIRM(T) page 112 S1BC4B-F / HYDROFIRM(T) EMC-FC page 114 TML round type B page 116 TML flat type B page 118 (N)TSW / MS-HYDROFIRM(T) page 120 Water - Cables for hot water page 123 TGSH / HYDROFIRM page 124 TGSH2G / HYDROFIRM page 12667 Technical AnnexCode acc. to VDE 0292 for Cables acc. to EN50525 page 130 Fire Testing Methods page 132 Conductors page 134 Compounds page 140 Electrical parameters page 141 EMC-Criteria page 149 Shield page 152 Chemical parameters page 153 cable Drum Overview page 154 Comparison page 155 Drum Handling page 156 Industry cables8 LOW voltage -RUBBER SHEATHED CABLES9 DesignationStandardFire performanceResistance to oilTemp.

5 Fully flex. operation voltageOZOFLEXH05RR-FDIN EN 50525-2-21 DIN EN 60332-1-2 DIN EN 60811-404-25 C300/500 VOZOFLEXH05RN-FDIN EN 50525-2-21 DIN EN 60332-1-2 DIN EN 60811-404-25 C300/500 VOZOFLEXH07RN-FDIN EN 50525-2-21 DIN EN 60332-1-2 DIN EN 60811-404-25 C450/750 VH05RR-FOZOFLEXR evision: 15. Dec 2016 Prysmian Kabel und Systeme GmbHAlt Moabit 91D, 10559 Berlinphone: +49 30 3675 40email: data, dimensions and weights aresubject to change. Prysmian Group , Germany flexible cable are suitable for transportable equipment of office and home application, etc. less mechanical stress, for connecting electricaltools and lamps also on construction Cables are not suitable for permanent immersion in waterIn other respects the specifications of DIN EN 50565-2 dataBrandOZOFLEX Type designationH05RR-F StandardEN 50525-2-21 Design featuresConductorCopper, finely stranded (F), class 5 in accordance with DIN EN 60228 / IEC 60228 InsulationVulcanized rubber compound, basis EPR, compound EI4 in accordance with EN 50363-1 Color codecolored in accordance with DIN EN 50525-1 Outer sheathVulcanized rubber compound, basis CPE, compound EM3 in accordance with EN 50363-2-1 Outer Sheath ColourBlack Electrical parametersRated voltage300/500V Max.

6 Permissible operating voltage kVMax. permissible operating voltage kVAC test voltage2 kVChemical parametersFlame propagationDIN EN 60332-1-2 Resistance to oilDIN EN 60811-404 Thermal parametersMax. permissible temperature at conductor 60 CMax. short circuit temperature of the conductor 250 C Ambient temperature for fix installation min. -25 CAmbient temp. in fully flex. operation min. -25 CMechanical parametersMax. tensile load on the conductor15 N/mm Min. bending radiusAcc. to DIN VDE 0298 part 3 10H05RR-FOZOFLEXH05RR-F11H05RR-FOZOFLEXH 05RR-FOZOFLEXR evision: 15. Dec 2016 Prysmian Kabel und Systeme GmbHAlt Moabit 91D, 10559 Berlinphone: +49 30 3675 40email: data, dimensions and weights aresubject to change. Prysmian Group , Germany of cores xcross (approx.)

7 Kg/kmPermis-sibletensileforce (1)AShortCircuitCurrent(conduc-tor)kA2 x x x x x (1) The values are valid for a cable in permanent operation with DC or AC with 50 up to 60 Hz at 30 C ambient temperature, on surface acc. toVDE 0298-4X = without gn/ye core, G = with gn/ye coreH05RR-FH05RN-FOZOFLEXR evision: 15. Dec 2016 Prysmian Kabel und Systeme GmbHAlt Moabit 91D, 10559 Berlinphone: +49 30 3675 40email: data, dimensions and weights aresubject to change. Prysmian Group , Germany flexible cable are suitable for transportable equipment of office and home application, etc.: medium mechanical stresses, for connectingelectrical tools and lamps also on construction Cables are not suitable for permanent immersion in waterIn other respects the specifications of DIN EN 50565-2 dataBrandOZOFLEX Type designationH05RN-F StandardEN 50525-2-21 Design featuresConductor MaterialBare copper ConductorCopper, finely stranded (F), class 5 in accordance with DIN EN 60228 / IEC 60228 InsulationVulcanized rubber compound, basis EPR, compound EI4 in accordance with EN 50363-1 Color codecolored in accordance with DIN EN 50525-1 Outer sheathsynthetic rubber compound, compound EM2 in accordance with EN 50363-2-1 Outer Sheath ColourBlack Electrical parametersRated voltage300/500V Max.

8 Permissible operating voltage kVMax. permissible operating voltage kVAC test voltage2 kVChemical parametersFlame propagationDIN EN 60332-1-2 Resistance to oilDIN EN 60811-404 Ozone resistanceDIN EN 50396 Thermal parametersMax. permissible temperature at conductor60 CMax. short circuit temperature of the conductor 250 C Ambient temperature for fix installation min. -25 CAmbient temp. in fully flex. operation CMechanical parametersMax. tensile load on the conductor15 N/mm Min. bending radiusAcc. to DIN VDE 0298 part 3 12H05RN-FOZOFLEXH05RN-F13H05RN-FOZOFLEXH 05RN-FOZOFLEXR evision: 15. Dec 2016 Prysmian Kabel und Systeme GmbHAlt Moabit 91D, 10559 Berlinphone: +49 30 3675 40email: data, dimensions and weights aresubject to change. Prysmian Group , Germany of cores xcross (approx.)

9 Kg/kmPermis-sibletensileforce (1)AShortCircuitCurrent(conduc-tor)kA2 x x G G x x G = without gn/ye core, G = with gn/ye core(1) The values are valid for a cable in permanent operation with DC or AC with 50 up to 60 Hz at 30 C ambient temperature, on surface acc. toVDE 0298-4H05RN-FH07RN-FOZOFLEXR evision: 15. Dec 2016 Prysmian Kabel und Systeme GmbHAlt Moabit 91D, 10559 Berlinphone: +49 30 3675 40email: data, dimensions and weights aresubject to change. Prysmian Group , Germany flexible cable are suitable for: Use in dry, humid or moist rooms and outdoors: transportable motors or machines on building sites orin agricultural workings, etc.: medium mechanical stresses, for industrial and agricultural workshop appliances, large boiling installations,heating plates, inspection lamps, electric tools such as drills, circular saws, domestic electric tools: Use in workshops having an explosiveatmosphere.

10 When a cable is to be used in the presence of explosive or flammable atmospheres, guidance should be sought by reference to EN60079 series of specifications and guidance should be sought in selecting suitable Cables . Fixed installations on rough-cast in temporarybuildings and huts for accommodation purposes: Wiring of constructional components in lifting appliances, machinery, up to 1000 V is permitted for fixed, protected installation (in conduit or appliances) and also for motor connections of hoisting motors andthe like. The Cables are not suitable for: Situations involving permanent immersion in other respects the specifications of DIN EN 50565-2 dataBrandOZOFLEX Type designationH07RN-F StandardEN 50525-2-21 Design featuresConductor MaterialBare copper Conductorbare copper, finely stranded (F), class 5 in accordance with DIN EN 60228 / IEC 60228 InsulationVulcanized rubber compound, basis EPR, compound EI4 in accordance with EN 50363-2-1 Color codein accordance with DIN EN 50525-1 Inner sheathfor multicore Cables with wall thickness of sheath > 2,4mm and control Cables : Vulcanized rubbercompound, basis EPR, compound EM2/EM3 in accordance with EN 50363-1 Colour of sheath.


Related search queries