Example: barber

INSTALLATION & OPERATING INSTRUCTIONS …

CUS Made in the USA by: goodman Manufacturing Company, North Loop West, Suite 400 - Houston, Texas 770926 or 2004-2006 goodman Manufacturing Company, & OPERATINGINSTRUCTIONS FORARUF, ARPF, ADPF, AEPFSERIES AIR 2 REPLACEMENT PARTS .. 2 SAFETY INSTRUCTIONS .. 2 WARNINGS .. 2-3 MODEL IDENTIFICATION .. 4 PRODUCT 4 UNIT 4 ELECTRIC 5 HKR INSTALLATION .. 6 ELECTRICAL SUPPLY WIRE AND 6 REFRIGERANT 7 AEPF MOTOR 8 CONVERSION TO 8 CONVERSION TO HORIZONTAL .. 9 CONDENSATE REMOVAL .. 10 ACHIEVING 2% LOW LEAKAGE RATE .. 10 ARUF/ARPF/ADPF 10 AEPF 10 THERMOSTAT WIRING 14 INTRODUCTIONC hecking Product ReceivedUpon receiving the product, inspect it for damage fromshipment.

C US Made in the USA by: Goodman Manufacturing Company, L.P. IO-286B 2550 North Loop West, Suite 400 - Houston, Texas 77092 6/06 www.goodmanmfg.com or www .amana-hac.com

Tags:

  Operating, Installation, Instructions, Amana, Goodman, Installation amp operating instructions

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of INSTALLATION & OPERATING INSTRUCTIONS …

1 CUS Made in the USA by: goodman Manufacturing Company, North Loop West, Suite 400 - Houston, Texas 770926 or 2004-2006 goodman Manufacturing Company, & OPERATINGINSTRUCTIONS FORARUF, ARPF, ADPF, AEPFSERIES AIR 2 REPLACEMENT PARTS .. 2 SAFETY INSTRUCTIONS .. 2 WARNINGS .. 2-3 MODEL IDENTIFICATION .. 4 PRODUCT 4 UNIT 4 ELECTRIC 5 HKR INSTALLATION .. 6 ELECTRICAL SUPPLY WIRE AND 6 REFRIGERANT 7 AEPF MOTOR 8 CONVERSION TO 8 CONVERSION TO HORIZONTAL .. 9 CONDENSATE REMOVAL .. 10 ACHIEVING 2% LOW LEAKAGE RATE .. 10 ARUF/ARPF/ADPF 10 AEPF 10 THERMOSTAT WIRING 14 INTRODUCTIONC hecking Product ReceivedUpon receiving the product, inspect it for damage fromshipment.

2 Claims for damage, either shipping or concealed,should be filed immediately with the shipping the product to determine if it is correct. In the eventan incorrect product is shipped, it must be returned to thesupplier and must NOT be installed. The manufacturerassumes no responsibility for INSTALLATION of incorrectlyshipped Beginning InstallationCarefully read all INSTRUCTIONS for the INSTALLATION prior toinstalling product. Make sure each step or procedure isunderstood and any special considerations are taken intoaccount before starting INSTALLATION . Assemble all tools,hardware and supplies needed to complete the items may need to be purchased locally.

3 Make sureeverything needed to install the product is on hand PARTSO rdering PartsWhen reporting shortages or damages, or ordering repairparts, give the complete product model and serial numbersas stamped on the product. Replacement parts for thisproduct are available through your contractor or localdistributor. For the location of your nearest distributorconsult the white business pages, the yellow page sectionof the local telephone book, or contact the following:SERVICE PARTS DEPARTMENTGOODMAN MANUFACTURING COMPANY, NORTH LOOP WEST, SUITE 400 HOUSTON, TEXAS 77092(713) 861 2500 IMPORTANT SAFETY INSTRUCTIONSR ecognize Safety Symbols, Words, and LabelsThe following symbols and labels are used throughout thismanual to indicate immediate or potential hazards.

4 It is theowner s responsibility to read and comply with all safetyinformation and INSTRUCTIONS accompanying these to heed safety information increases the risk ofserious personal injury or death, property damage and/orproduct OR UNSAFE PRACTICES COULD RESULT INPROPERTY DAMAGE, PRODUCT DAMAGE, SEVEREPERSONAL INJURY OR UNIT MUST HAVE AN UNINTERRUPTED,UNBROKEN ELECTRICAL GROUND TO MINIMIZE THEPOSSIBILITY OF PERSONAL INJURY IF AN ELECTRICALFAULT SHOULD OCCUR. THE ELECTRICAL GROUNDCIRCUIT MAY CONSIST OF AN APPROPRIATELY SIZEDELECTRICAL WIRE CONNECTING THE GROUND LUGIN THE UNIT CONTROL BOX TO THE BUILDINGELECTRICAL SERVICE PANEL. OTHER METHODS OFGROUNDING ARE PERMITTED IF PERFORMED INACCORDANCE WITH THE NATIONAL ELECTRIC CODE (NEC)/ AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI)/ NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 70 AND LOCAL/STATE CODES.

5 IN CANADA,ELECTRICAL GROUNDING IS TO BE IN ACCORDANCEWITH THE CANADIAN ELECTRIC CODE CSA TO OBSERVE THIS WARNING CAN RESULT INELECTRICAL SHOCK THAT CAN CAUSE VOLTAGE!DISCONNECT ALL POWER BEFORE SERVICING ORINSTALLING THIS UNIT. MULTIPLE POWER SOURCESMAY BE PRESENT. FAILURE TO DO SO MAY CAUSEPROPERTY DAMAGE, PERSONAL INJURY, OR TO HIGH SYSTEM PRESSURE AND ELECTRICALSHOCK POTENTIAL, INSTALLING AND THE SERVICINGAIR CONDITIONING SYSTEMS CAN BE QUALIFIED AND PROFESSIONALLY TRAINEDPERSONNEL ARE PERMITTED TO INSTALL OR SERVICETHIS EQUIPMENT. OBSERVE ALL WARNINGSCONTAINED IN THIS MANUAL AND LABELS/TAGSATTACHED TO THE INDIVIDUALS MEETING THE REQUIREMENTS OFAN ENTRY LEVEL TECHNICIAN AS SPECIFIED BY THEAIR CONDITIONING AND REFRIGERATION INSTITUTE(ARI) MAY USE THIS INFOMRATION.

6 ATTEMPTIMG TOINSTALL OR REPAIR THIS UNIT WITHOUT SUCHBACKGROUND MAY RESULT IN PRODUCT DAMAGE,PERSONAL INJURY, OR PREVENT THE RISK OF PROPERTY DAMAGE,PERSONAL INJURY, OR DEATH, DO NOT STORECOMBUSTIBLE MATERIALS OR USE GASOLINE OROTHER FLAMMABLE LIQUIDS OR VAPORS IN THEVICINITY OF THIS APPLIANCE. CARBON MONOXIDE POISONING HAZARD - Special Warning for INSTALLATION of Furnace or Air Handling Units inEnclosed Areas such as Garages, Utility Rooms or Parking AreasCarbon monoxide producing devices (such as an automobile, spaceheater, gas water heater, etc.) should not be operated in enclosed areassuch as unventilated garages, utility rooms or parking areas because ofthe danger of carbon monoxide (CO) poisoning resulting from the exhaustemissions.

7 If a furnace or air handler is installed in an enclosed area suchas a garage, utility room or parking area and a carbon monoxide producingdevice is operated therein, there must be adequate, direct ventilation is necessary to avoid the danger of CO poisoning whichcan occur if a carbon monoxide producing device continues to operate inthe enclosed area. Carbon monoxide emissions can be (re)circulatedthroughout the structure if the furnace or air handler is OPERATING in can cause serious illness including permanent brain damage or PRODUCT IS FACTORY SHIPPED FOR USE WITH A208-240/1/60 ELECTRICAL POWER SUPPLY. THIS AIRHANDLER MUST NOT BE RECONFIGURED TO OPERATEWITH ANY OTHER POWER INSTALLING OR SERVICING THIS EQUIPMENT,SAFETY CLOTHING, INCLUDING HAND AND EYEPROTECTION, IS STRONGLY ADVISED.

8 IF INSTALLINGTHIS EQUIPMENT IN AN AREA THAT HAS SPECIAL SAFETYREQUIREMENTS (HARD HATS ETC.), OBSERVE THESEREQUIREMENTS. TO PROTECT THE UNIT WHENWELDING CLOSE TO THE PAINTED SURFACES, THE USEOF A QUENCHING CLOTH IS STRONGLY ADVISED TOPREVENT SCORCHING OR MARRING OF THEEQUIPMENT UNITED STATES ENVIRONMENTAL PROTECTIONAGENCY ( EPA ) HAS ISSUED VARIOUS REGULATIONSREGARDING THE INTRODUCTION AND DISPOSAL OFREFRIGERANTS INTRODUCED INTO THIS TO FOLLOW THESE REGULATIONS MAY HARMTHE ENVIRONMENT AND CAN LEAD TO THE IMPOSITIONOF SUBSTANTIAL FINES. THESE REGULATIONS MAYVARY BY JURISDICTION. A CERTIFIED TECHNICIAN MUSTPERFORM THE INSTALLATION AND SERVICE OF THISPRODUCT.

9 SHOULD QUESTIONS ARISE, CONTACTYOUR LOCAL EPA NOT CONNECT TO OR USE ANY DEVICE THAT ISNOT DESIGN CERTIFIED BY goodman FOR USE WITHTHIS UNIT. SERIOUS PROPERTY DAMAGE, PERSONALINJURY, REDUCED UNIT PERFORMANCE AND/ORHAZARDOUS CONDITIONS MAY RESULT FROM THE USEOF SUCH NON-APPROVED IDENTIFICATIONARUF364216 AAProduct Type:A: Single PieceAir HandlerApplication:C: Ceiling MountPSC MotorD: DownflowPSC MotorE: Multi-PositionVariable Speed MotorR: Multi-PositionPSC MotorW: Wall MountPSC MotorCabinet Finish:U: UnpaintedP: PaintedN: UncasedExpansionDevice:Nominal Capacity RangeMulti-Position & Downflow Applications@ 13 SEER:3642: 3 to 31/2 tons1830: 1 1/2 to 3 1/2 tons@ 10 SEER:1729: 1 1/2 to 2 1/2 tons (For export systems)Nominal Cooling Capacity/Electric Heat kw.

10 Ceiling Mount & Wall Mount Applications1805: 1 1/2 tons cooling/5 kw electric heat2405: 2 tons cooling/5 kw electric heat3608: 3 tons cooling/8 kw electric heatElectrical:1: 208/240V1 Phase60 HzRefrigerant:NOMENCLATUREWith the exception of Dedicated Downflow Air Handlers,the models addressed in this manual may be installed inupflow, downflow, and horizontal configurations. DEDICATED DOWNFLOW MODELS MAY NOT BEINSTALLED IN UPFLOW OR HORIZONTALCONFIGURATIONS. Dedicated Downflow models areindicated by a D in the Application column. The letter D appearing in any location other than that specifiedin the chart above does not indicate a DedicatedDown-flow model.


Related search queries