Installation and operating instructions for the MAX …

45833A Printed in Canada 22-04-2016 Installation and operating instructions for the MAX CADDY WOOD furnace (PF01102 model) Certified according to CSA , CSA , UL391, CSA , UL 1995, CAN/CSA and UL 727 furnace MODELS INCLUDED IN THIS MANUAL WOOD ONLY COMBINATION 20 kW / 25 kW AND OIL Read these instructions carefully before installing and operating your furnace . CONGRATULATIONS! You have purchased one of the finest wood or combination furnaces available on the market. We are confident that your furnace will provide years of comfort and safe operation. Please keep this document! Verified and tested for Canada and the United States by an accredited laboratory. This manual is available for free download on the manufacturer s web site. It is a copyrighted document. Re-sale is strictly prohibited. The manufacturer may update this manual from time to time and cannot be responsible for problems, injuries, or damages arising out of the use of information contained in any manual obtained from unauthorized sources.

45833A Printed in Canada 22-04-2016 Installation and operating instructions for the MAX CADDY WOOD FURNACE (PF01102 model) Certified according to CSA B415.1-10, CSA B366.1, UL391,

Tags:

  Operating, Installation, Instructions, Woods, Furnace, Installation and operating instructions for, Wood furnace

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Installation and operating instructions for the MAX …

1 45833A Printed in Canada 22-04-2016 Installation and operating instructions for the MAX CADDY WOOD furnace (PF01102 model) Certified according to CSA , CSA , UL391, CSA , UL 1995, CAN/CSA and UL 727 furnace MODELS INCLUDED IN THIS MANUAL WOOD ONLY COMBINATION 20 kW / 25 kW AND OIL Read these instructions carefully before installing and operating your furnace . CONGRATULATIONS! You have purchased one of the finest wood or combination furnaces available on the market. We are confident that your furnace will provide years of comfort and safe operation. Please keep this document! Verified and tested for Canada and the United States by an accredited laboratory. This manual is available for free download on the manufacturer s web site. It is a copyrighted document. Re-sale is strictly prohibited. The manufacturer may update this manual from time to time and cannot be responsible for problems, injuries, or damages arising out of the use of information contained in any manual obtained from unauthorized sources.

2 Eco-energy at the hearth of your home PSG 250, de Copenhague, St-Augustin-de-Desmaures (Quebec) CANADA G3A 2H3 2 TABLE OF CONTENT 1. INTRODUCTION .. 5 2. APPLIANCE PERFORMANCE(1) .. 6 3. GENERAL FEATURES .. 7 4. SPECIFICATIONS .. 8 5. MAX CADDY furnace TECHNICAL DATA .. 9 6. furnace DIMENSIONS .. 9 7. CHIMNEY AND DRAFT .. 11 8. SAFETY RULES .. 11 GENERAL REQUIREMENTS .. 11 ODOUR FROM THE PAINT .. 11 ASH DISPOSAL .. 11 CREOSOTE BUILD-UP AND 11 SMOKE DETECTOR .. 12 DOOR GLASS .. 12 GLASS SPECIFICATIONS .. 12 ASH DRAWER .. 12 ASH GRATE .. 12 MAX CADDY WOOD ONLY furnace , COMBINED WOOD / ELECTRIC OR PARALLEL ADD-ON PF01102 .. 13 9. Installation instructions .. 14 BLOWER Installation .. 14 LINK BOARD Installation AND CONNECTION .. 14 TOUCHSCREEN Installation AND CONNECTION .. 18 HOT AIR PLENUM TEMPERATURE PROBE Installation AND CONNECTION (RTD) .. 19 SERVOMOTOR Installation AND 20 UNIT LOCATION .. 21 MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS AND FLOOR PROTECTION.

3 21 MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS .. 22 MINIMUM CLEARANCES TO COMBUSTIBLES MATERIALS FOR AIR RETURN DUCT .. 23 MINIMUM CLEARANCES TO COMBUSTIBLES MATERIALS FOR HOT AIR PLENUM .. 23 FLOOR PROTECTION .. 23 FLUE AND BAROMETRIC DRAFT CONTROL CONNECTION .. 24 ELECTRICAL CONNECTIONS .. 25 DAMPER .. 25 COMBUSTION AIR AND FRESH AIR INTAKE ADAPTER Installation (OPTIONAL) .. 25 HOT AIR PLENUM .. 26 PARALLEL Installation .. 26 ELECTRICAL ELEMENT Installation (OPTIONAL).. 29 INTRODUCTION .. 29 CONNECTING THE ELECTRICAL ELEMENT .. 29 10. THERMOSTAT Installation .. 30 WOOD furnace 30 COMBINATION WOOD-ELECTRIC OR WOOD-OIL furnace .. 30 COMBINATION WOOD-ELECTRIC-OIL .. 30 Installation OF AN AIR CONDITIONING UNIT .. 31 HEATPUMP Installation .. 31 Installation OF A DOMESTIC WATER PRE-HEATING SYSTEM OR A HUMIDIFIER .. 32 11. CONFIGURATION AND operating instructions .. 32 CONTROLS SYSTEM .. 32 SYSTEM CONFIGURATION .. 33 TOUCH SCREEN .. 33 ICONS DESCRIPTION.

4 33 LANGUAGE SELECTION AND TEMPERATURE 34 ADDING AUXILIARY HEATING SOURCE AND SELECTION OF OPTIONS .. 34 TRANSITION TO AN AUXILIARY HEAT SOURCE .. 34 TRANSITION SETTINGS .. 34 AUXILIARY HEAT SOURCE PRIORITIZATION .. 35 EXTERNAL TEMPERATURE PROBE .. 35 BI-ENERGY FUNCTION .. 35 DISTRIBUTION BLOWER SPEED CONFIGURATION .. 36 DISTRIBUTION FAN SPEEDS .. 36 SYSTEM BALANCING .. 36 operating instructions .. 37 HEAT MODE .. 37 3 COOL MODE .. 37 CIRC MODE (AIR CIRCULATION) .. 37 WOOD HEATING .. 38 LIGHTING .. 38 PREHEATING .. 38 HEATING .. 38 EARLY SIGNS OF AN OVERFIRED furnace : .. 38 WOOD AS HEATING FUEL .. 39 PROLONGED POWER FAILURE .. 39 CHIMNEY FIRES .. 39 LOCAL FIRE DEPARTMENT .. 39 12. MAINTENANCE .. 40 MAINTENANCE OF THE EXCHANGERS .. 40 CHIMNEY MAINTENANCE .. 41 SMOKE PIPE INSPECTION .. 41 BLOWER MOTOR MAINTENANCE .. 41 FILTERS .. 41 AIR FILTER DIMENSIONS .. 41 DOOR GASKET MAINTENANCE .. 41 DOOR ADJUSTMENT PROCEDURE.

5 41 13. REPLACEMENT PARTS .. 42 DOOR GLASS .. 42 GASKET .. 42 14. TROUBLESHOOTING .. 42 VALIDATING STATUS OF A COMPONENT .. 43 DISTRIBUTION BLOWER .. 43 AIR DAMPER, HOT WATER AND HUMIDIFIER .. 43 TEMPERATURE PROBE (RTD) .. 44 MAIN ERROR CODES, POSSIBLE CAUSES AND SOLUTIONS .. 44 UNIT OVERHEAT .. 44 NO HEAT .. 45 COMMUNICATION ERROR .. 45 SMOKE SMELL .. 46 THE LCD TOUCH SCREEN DOES NOT LIGHTUP.. 46 AUXILIARY OVERRIDE .. 46 15. GENERAL ELECTRICAL DIAGRAM .. 47 16. ELECTRICAL DIAGRAM FOR PARALLEL furnace .. 48 17. ELECTRICAL DIAGRAM FOR ELECTRIC UNIT .. 49 WOOD/OIL COMBINATION furnace .. 50 18. GENERAL NOTES .. 52 19. DRAFT AND CHIMNEY .. 52 20. OIL TANK AND PIPING .. 52 21. BURNER 52 22. APPLIANCE Installation .. 53 UNIT LOCATION .. 53 PARALLEL Installation .. 53 MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS .. 53 FLOOR PROTECTION .. 54 HOT AIR PLENUM .. 54 CONNECTING PIPE AND MANUAL DAMPER .. 54 DIFFERENT Installation .. 55 COMBUSTION 56 ELECTRICAL WIRING.

6 56 THERMOSTAT .. 56 23. OPERATION INSTRUCTION .. 56 FAN SPEED CONTROL .. 56 COMBUSTION SAFETY CONTROL .. 56 PRE-PURGE .. 56 SAFE OPERATION .. 56 4 TEMPORARY DISENGAGEMENT OF THE BURNER .. 56 COMBUSTION ADJUSTMENT AND VERIFICATION .. 57 COMBUSTION VERIFICATION PROCEDURE: .. 57 ELECTRODES SETTING .. 58 APPLIANCE START-UP .. 59 PROLONGED CLOSING .. 59 24. TECHNICAL DATA .. 59 UH MAX CADDY .. 59 25. MAINTENANCE .. 59 MAINTENANCE .. 59 SERVICE .. 60 FILTERS .. 60 26. ELECTRICAL DIAGRAM BECKETT OIL UNIT .. 61 27. ELECTRICAL DIAGRAM RIELLO OIL UNIT .. 62 28. LINK BOARD OPTIONS CONNECTIONS .. 63 ELECTRICAL CONSUMPTION .. 63 OUTDOOR PROBE .. 63 HOT WATER .. 63 24V ADDITIONNAL EQUIPMENT .. 64 AIR CONDITIONNING 64 HUMIDIFIER .. 64 HEAT PUMP .. 65 29. EXPLODED VIEW AND PART LIST .. 65 PSG LIMITED LIFETIME WARRANTY (REGULAR) .. 78 PSG LIMITED LIFETIME WARRANTY (PRIVILEGE) .. 79 5 IMPORTANT NOTE: THE Installation OF THIS CENTRAL HEATING SYSTEM MUST BE PERFORMED BY A QUALIFIED TECHNICIAN.

7 PSG RESERVES ITSELF THE RIGHT TO VOID ITS WARRANTY OR DENY TECHNICAL ADVICE IF THE furnace HAS NOT BEEN SOLD OR INSTALLED BY A PROFESSIONAL. REGISTER YOU WARRANTY ONLINE To receive full warranty coverage, you will need to show evidence of the date you purchased your furnace . Keep your sales invoice. We also recommend that you register your warranty online at Registering your warranty online will help us track rapidly the information we need on your furnace . WARNING : THE Installation OF THIS APPLIANCE REQUIRES THE ADDITION OF A BLOWER ASSEMBLY (PA08566) NOT INCLUDED. 1. INTRODUCTION Take note that this furnace operates like an EPA wood burning stove. This applies to the lighting, the ember bed, and the minimum combustion air intake which was determined based on the use of good seasoned cordwood. The Max Caddy furnace was tested and approved according to the CSA Standard. To optimize the efficiency of your furnace , here is some advice that you should follow when installing or operating your Max Caddy.

8 Respect the local codes (when in doubt, consult your local dealer); Make sure your furnace is installed according to the instructions on the certification label; All controls and adjustments must be performed by a qualified technician. The blower speed must conform to the recommendations of local codes and should respect the static pressure ranges in the warm air plenum of the furnace . We recommend that our wood burning hearth products be installed and serviced by professionals who are certified in the United States by NFI (National Fireplace Institute ) or in Canada by WETT (Wood Energy Technical Training) or in Quebec by APC (Association des Professionnels du Chauffage). 6 2. APPLIANCE PERFORMANCE(1) Fuel type Dry cordwood Recommended heating area[*] 1,500 to 3,500 ft (139 to 325 m ) Firebox volume ft ( m ) Maximum burn time[*] 17 hours Maximum input capacity (dry cordwood)(2) 421,000 BTU Overall heat output rate (min. to max.)(3) 19,243 BTU/h to 67,069 BTU/h ( kW to kW) Nominal heat output at 15lb/ft fuel loading density 100,000 BTU/h Average overall efficiency(4) (HHV)(5) 85 % (LHV)(6) Delivered heat output rate (min.)

9 To max.)(7) 16,109 BTU/h to 54,578 BTU/h ( kW to kW) Average delivered efficiency(8) (HHV)(5) (LHV)(6) Optimum efficiency(9) Average particulate emissions rate(10)(11) lb/mmBTU ( g/MJ) Average CO(12) lb/mmBTU ( g/MJ) Average electrical power consumption (13) 360 Wh [*] Recommended heating area and maximum burn time may vary subject to location in home, chimney draft, heat loss factors, climate, fuel type and other variables. The recommended heating area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature considering that the space configuration and the presence of heat distribution systems have a significant impact in making heat circulation optimum. (1) Values are as measured per CSA , except for the recommended heating area, firebox volume, maximum burn time and maximum input capacity. Performances based on a fuel load prescribed by the standard at 10 lb/ft and with moisture content between 18% and 28%.

10 (2) Input value at 10lb/ft fuel loading density and dry energy value of 8,600 BTU/lb. (3) Overall: Radiated and delivered heat together at10lb/ft fuel loading density over one total burn cycle. (4) Efficiency based on delivered heat when allowing cycling from high to low burn to simulate thermostat demand. (5) Higher Heating Value of the fuel. (6) Lower Heating Value of the fuel. (7) Delivered: Remotely provided to other rooms through ducting at 10 lb/ft fuel loading density over one total burn cycle. (8) Efficiency based on radiated and delivered heat when allowing cycling from high to low burn to simulate thermostat demand. (9) Optimum overall efficiency at a specific burn rate (LHV). (10) Based on delivered heat output. (11) This appliance is officially tested and certified by an independent agency. (12) Carbon Monoxyde. Based on overall heat output at 10lb/ft fuel loading density. (13) Unless stated otherwise, measures were taken directly at the main power source and include all electrical components present in the appliance.