Example: bachelor of science

Installation and operating instructions - net.grundfos.com

grundfos instructions . SP. Stainless steel submersible pumps 4", 6", 8", and 10". Installation and operating instructions English (US) Installation and operating instructions English (US). Original Installation and operating instructions WARNING. CONTENTS Prior to Installation , read these Installation and operating instructions . Page Installation and operation must 1. Limited warranty 3 comply with local regulations and accepted codes of good practice. 2. Symbols used in this document 3. Keep this booklet with the pump for 3. Product description 4 future reference and information Introduction 4 regarding its operation. Applications 4. Features and benefits 4 WARNING.

and not by Grundfos' warr anty. Grundfos will not be liable for damage or wear to products caused by abnormal operating conditions, accident, abuse, misuse, unauthorized alteration or repair, or if the product was not installed in accordance with Grundfos' printed installation and operating instructions. To obtain service under this warranty, the

Tags:

  Instructions, Grundfos

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Installation and operating instructions - net.grundfos.com

1 grundfos instructions . SP. Stainless steel submersible pumps 4", 6", 8", and 10". Installation and operating instructions English (US) Installation and operating instructions English (US). Original Installation and operating instructions WARNING. CONTENTS Prior to Installation , read these Installation and operating instructions . Page Installation and operation must 1. Limited warranty 3 comply with local regulations and accepted codes of good practice. 2. Symbols used in this document 3. Keep this booklet with the pump for 3. Product description 4 future reference and information Introduction 4 regarding its operation. Applications 4. Features and benefits 4 WARNING.

2 Type key 4. The Installation of this product 4. Delivery, handling and storage 4 requires experience with and Delivery 4 knowledge of the product. Handling 4 Persons with reduced physical, Storage 5 sensory or mental capabilities must 5. operating conditions 5 not use this product, unless they are under supervision or have been 6. Installation 5 instructed in the use of the product by Pre- Installation checklist 5 a person responsible for their safety. Positional requirements 6 Children must not use or play with this Preparation 7 product. Removing and fitting the cable guard 9. Splicing the motor cable 9. Riser pipe 10. Electrical and variable-frequency drive information 12.

3 7. Startup 20. Startup with three-phase motors 20. 8. Operation 22. Minimum flow rate 22. Soft starter 23. Maintenance and service 23. 9. Troubleshooting 23. Preliminary tests 24. Checking pump performance 25. Troubleshooting chart 26. 10. Technical data 30. Motor cooling requirements 30. Guide for engine-driven generators in submersible pump applications 31. Transformer capacity required for three-phase submersible motors 32. Submersible drop cable selection charts (60 Hz) 32. Approvals 38. Electrical data 39. 11. Disposal 42. 2. 1. Limited warranty 2. Symbols used in this document English (US). Products manufactured by grundfos PUMPS. CORPORATION ( grundfos ) are warranted to WARNING.

4 The original user only to be free of defects in material and workmanship for a period of 24 If these safety instructions are not months from date of Installation , but not more observed, it may result in personal than 30 months from date of manufacture. injury. grundfos ' liability under this warranty shall be limited to repairing or replacing at grundfos '. option, without charge, FOB grundfos ' factory or WARNING. authorized service station, any product of If these instructions are not observed, grundfos ' manufacture. grundfos will not be it may lead to electric shock with liable for any costs of removal, Installation , consequent risk of serious personal transportation, or any other charges which may injury or death.

5 Arise in connection with a warranty claim. Products which are sold but not manufactured by grundfos are subject to the warranty CAUTION. provided by the manufacturer of said products Caution If these safety instructions are not and not by grundfos ' warranty. grundfos will not observed, it may result in malfunction be liable for damage or wear to products caused or damage to the equipment. by abnormal operating conditions, accident, abuse, misuse, unauthorized alteration or repair, Notes or instructions that make the or if the product was not installed in accordance Note job easier and ensure safe operation. with grundfos ' printed Installation and operating instructions .

6 To obtain service under this warranty, the defective product must be returned to the distributor or dealer of grundfos ' products from which it was purchased together with proof of purchase and Installation date, failure date, and supporting Installation data. Unless otherwise provided, the distributor or dealer will contact grundfos or an authorized service station for instructions . Any defective product to be returned to grundfos or a service station must be sent freight prepaid; documentation supporting the warranty claim and/or a Return Material Authorization must be included if so instructed. grundfos WILL NOT BE LIABLE FOR ANY. INCIDENTAL OR CONSEQUENTIAL.

7 DAMAGES, LOSSES, OR EXPENSES ARISING. FROM Installation , USE, OR ANY OTHER. CAUSES. THERE ARE NO EXPRESS OR. IMPLIED WARRANTIES, INCLUDING. MERCHANTABILITY OR FITNESS FOR A. PARTICULAR PURPOSE, WHICH EXTEND. BEYOND THOSE WARRANTIES DESCRIBED. OR REFERRED TO ABOVE. Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages and some jurisdictions do not allow limit actions on how long implied warranties may last. Therefore, the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from jurisdiction to jurisdiction. 3. 3. Product description 4.

8 Delivery, handling and storage English (US). Introduction Delivery Your grundfos SP submersible pump is of the highest quality. Combined with proper CAUTION. Installation , your grundfos pump will give you many years of reliable service. Keep the pump in the shipping carton Caution until it is placed in the vertical position To ensure the proper Installation of the pump, during Installation . carefully read the complete manual before attempting to install the pump. Handle the pump with care. Examine the components carefully to make sure Applications no damage has occurred to the pump end, grundfos SP submersible pumps are suitable for motor, cable or control box during shipment.

9 The following applications: groundwater supply to waterworks Handling irrigation in horticulture and agriculture Keep the pump in the shipping carton until it is ready to be installed. The shipping carton is groundwater lowering (dewatering). specially designed to protect it from damage. pressure boosting During unpacking and prior to Installation , make industrial applications sure that the pump is not dropped or domestic water supply. mishandled. Do not expose the pump to unnecessary impact Features and benefits and shocks. State-of-the-art hydraulics provide high The motor is equipped with a power cable. efficiency and low operating costs 100 % stainless steel components inside and CAUTION.

10 Outside for long service life Caution Never use the power cable to support sand resistant the weight of the pump. resistant to aggressive water You will find a loose nameplate with an adhesive monitoring, protection, and communication backing with the pump. If the nameplate is via protection unit MP 204, and GO remote blank, complete it in pen and attach it to the control. control box. Type key Fix the extra nameplate supplied with Note the pump at the Installation site. Example 475 S 500 - 5 - A B. Rated flow rate in gpm Type range Stainless steel parts of material S = AISI 304. N = AISI 316. R = AISI 904L. Hp of motor Number of impellers First reduced-diameter impeller (A, B or C).


Related search queries