Example: quiz answers

INSTALLATION and OPERATION 5 6 ELITE …

IMPORTANT SAFEGUARDS If the plug or socket does get wet, DO NOT unplug the cord. Disconnect the fuse or circuit breaker that supplies INSTALLATION and OPERATION 6. 7. Remove impeller cover. Grasp the blades of the impeller fan and pull out the 5 6 GUARANTEE. ELITE STINGRAY. WARNING-To guard against injury, basic safety pre- cautions should be observed including the following: power to the appliance. Then unplug and examine for the presence of water in the socket. 7. WARNING: To prevent electric shock, supply electrical power through a wall mounted Residual Current Device ! CAUTION: Disconnect the electrical plug of all appliances inside the aquarium before putting hands into the water.

SERVICE Si cet appareil vous semble défectueux ou que vous vous posez des questions quant à son fonctionnement, n’hésitez pas à communiquer

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of INSTALLATION and OPERATION 5 6 ELITE …

1 IMPORTANT SAFEGUARDS If the plug or socket does get wet, DO NOT unplug the cord. Disconnect the fuse or circuit breaker that supplies INSTALLATION and OPERATION 6. 7. Remove impeller cover. Grasp the blades of the impeller fan and pull out the 5 6 GUARANTEE. ELITE STINGRAY. WARNING-To guard against injury, basic safety pre- cautions should be observed including the following: power to the appliance. Then unplug and examine for the presence of water in the socket. 7. WARNING: To prevent electric shock, supply electrical power through a wall mounted Residual Current Device ! CAUTION: Disconnect the electrical plug of all appliances inside the aquarium before putting hands into the water.

2 8. impeller. Rinse off any slimy buildup that has accumulated on the magnetic impeller and in the impeller well and reassemble. STINGRAY 5, 10, 15 UNDERWATER FILTERS are uncondi- tionally guaranteed for a period of 2 years. This guarantee is valid only under normal operating conditions for which READ AND FOLLOW ALL SAFETY (GFI-Ground Fault Current Interrupter) with a residual STINGRAY 9. Once all parts are cleaned or replaced, reassemble the the filters are intended. This guarantee will not apply to any U N D E R W AT E R F I LT E R S INSTRUCTIONS operating current not exceeding 30mA. If the appliance INSTALLATION filter and install in the aquarium.

3 Unit subjected to improper use, negligence or tampering. This guarantee does not include any responsibility for shows any sign of current leakage or if the GFI switches It is recommended that the sponge 1. DANGER-To avoid possible electric shock, special care off, disconnect the power supply from mains and remove * Do not rinse the sponge pad directly in the aquarium. animate material contained in the aquarium and is limited pads are rinsed before the first should be taken since water is employed in the use of the appliance from the water. INSTALLATION (see STINGRAY Transfer a small quantity of water from the aquarium into to the STINGRAY UNDERWATER FILTERS only.)

4 The motor aquarium equipment. Follow these safety instructions MAINTENANCE AND a bucket using a siphon. After rinsing, put the sponge is factory sealed, tampering will void guarantee. carefully. 8. WARNING: Do not permit children to use this back in the filter intake and reassemble. 7. appliance unless they are closely supervised by an adult at REPLACEMENT). *. 2. All aquarium appliances must be disconnected from all times. 1. Place the filter in the aquarium the main power supply before servicing an aquarium or 9. WARNING: Do not use an appliance for other than its using the suction cups, ensuring that the horizontal water outlet SERVICE.

5 Conducting any activity that allows direct contact with the intended use. The use of attachments not recommended is at a minimum of 1 cm below If you have a problem or question about the OPERATION of this water. the water surface. or sold by the appliance manufacturer may cause an 2 product, please let us try to help you before you return the product WARNING: Disconnect the power from all aquarium unsafe condition. 2. Plug into power source. to your dealer. Most problems can be handled promptly with a appliances before putting hands into the aquarium. phone call. When you call (or write), please have all relevant 10. WARNING: Do not immerse this appliance deeper than 3.

6 Do not operate any aquarium appliance which mal- 1 meter or 40 inches. FILTER MAINTENANCE information such as model number and/or part numbers available, functions or is damaged in any way. The power cord of as well as the nature of the problem. Call our Customer Service 11. WARNING: Do not operate this appliance out of water. CAUTION: Disconnect the electrical plug of all appliances this appliance cannot be replaced. If the electrical cord or inside the aquarium before putting hands in the water. Department: Art. # A-144 Always unplug an appliance when not in use, before plug is damaged, discard the appliance. We recommend cleaning the filter media (carbon zeolite putting on or taking off parts, and before cleaning.)

7 Never Canada Only: Toll-Free Number 1-800-55 HAGEN. 4. WARNING: The motor has no user serviceable parts. yank cord to pull plug from socket. Grasp the plug and pull cartridge and sponge pads), magnetic impeller and impeller (1-800-554-2436). Do not attempt repairs yourself; return the appliance to well (where the magnetic impeller is located) at least once to disconnect. a month. It's a good idea to clean the motor when Between 8:30 AM and 5:00 PM Eastern Time. an authorized service facility for service or discard the 1) 2). 12. Do not install or store the appliance where it will servicing the filter media. Filter media should be replaced Only: Toll-Free Number 1-800-724-2436.

8 Appliance. every 2 months to ensure proper functioning of the pump. 3. be exposed to the weather or to temperatures below Between 8:30 AM and 4:00 PM Eastern Time. 5. To avoid the possibility of the freezing. Never change all media at one time. Art. # A-142 Only: Helpline Number 01977 556622. appliance or socket getting wet, position the aquarium to one side 13. Make sure the appliance is securely installed STINGRAY MAINTENANCE AND Between 9:00 AM and 5:00 PM. before operating it. of a wall-mounted socket prevent- REPLACEMENT STINGRAY REPLACEMENT PARTS For Authorized Warranty Repair Service: ing water from dripping onto the 14. Read and observe all the important notices on the socket or plug.

9 Appliance. 1. Slowly remove the filter from Return unit with dated receipt and reason for return to: the aquarium, keeping the Canada: Rolf C. Hagen Inc. 6. WARNING: Use a drip loop. A 15. If an extension cord is necessary, an electrical cord filter in a horizontal position drip loop (see illustration) with a proper rating should be used. An electrical cord to avoid releasing the debris 3225 Sartelon St., Montreal, Quebec, H4R 1E8. Art. # A-140. should be arranged by the user for rated for less amperes or watts than the appliance rating collected inside. : Rolf C. Hagen (USA) Corp. each cord connecting an aquarium may overheat. Care should be taken to arrange the cord so 2.

10 Remove the filter lid. 4 50 Hampden Road, Mansfield, MA. 02048. appliance to a socket. The drip that it will not be tripped over or pulled. 3. Remove the sponge pads : Rolf C. Hagen (UK) Ltd. loop is that part of the electrical 16. CAUTION: To prevent corrosion or deterioration of from the filter and the intake 1 California Dr., Whitwood Ind. Est., Castleford, cord below the level of the socket materials that could lead to electrical shock, use only with chamber. Rinse* or replace. West Yorkshire WF10 5QH. Distributed by: (or the connector if an extension fresh water. 4. Remove the carbon/zeolite Canada: Rolf C. Hagen Inc., Montreal, QC H4R 1E8 cord is used) to prevent water from cartridges.