Transcription of INSTALLATION AND REPAIR GUIDE - Ramsond …
1 INSTALLATION AND REPAIR GUIDES plit Wall- mounted Air ConditionerForewordSelection of INSTALLATION positions for indoor unitSelection of INSTALLATION positions for outdoor unitInstallation fixture of indoor unitInstallation fixture of outdoor unitOrdinary pipelines connection & Air purgingPipelines connection for Split type quick coupler modelPipelines connection for Whole-Unit type quick coupler modelConnection of power cableFinishing touches and test runningIs the unit installed correctly?Self diagnosis functionsQuick connector INSTALLATION instructionInstallation GuideCONTENTSAir conditioners are units that should have the professional technicians do theinstallation for Instruction GUIDE is the universal-purpose version for the models of splitwall- mounted air conditioners manufactured by our Co.
2 The appearance of theunits that you purchase might be slightly different from the ones described inthe GUIDE , but it does not affect your proper operations and read carefully the sections corresponding to the specific model youchoose, and keep the GUIDE properly so as to facilitate your reference at *Selection of INSTALLATION positions for indoor unit** To be installed at the position where the air delivered from the unit can reach every corner ofthe room;* To avoid being affected by the outdoor air;* To avoid blockage to the air inlet or outlet of the unit;* To avoid too much oil smoke or steam;* To avoid possible generation, inflow, lingering or leakage of flammable gases;* To avoid high-frequency facilities (such as high frequency arc welders, etc.)
3 ;* To avoid the places where acid solutions are frequently used;* To avoid the places where some special sprayers (sulfides) are frequently used.* Not to install on top of the musical instruments,TV,computer appliance.* Not to install a fire alarming device near the air outlet of the unit (during operation, the fire alarmdevice might be erroneously triggered by the warm air from the unit); INSTALLATION & REPAIR GUIDES plit Wall- mounted Air Conditioner* Height limits of indoor and outdoor units.* Either the indoor unit or the outdoor unit can be higher, but the height difference must comply the stated requirements.* Try to reduce the bending of the piping line as much as possible so as to avoid possible negative impacts upon theperformances of the unitoutdoorunit5m(16'5") :If there are some additional function devices to install on the air conditioner,Besure add to the INSTALLATION space for the function 100mm(4")Left side: 150mm(6") and above from wallRight side: 150mm (6")and above from wallCeilingWall hanging plateground2300mm(7'6") and above* Make sure of enough space for INSTALLATION and maintenance.
4 * To take into consideration the operational convenience and safety in INSTALLATION , it is recommendedto ensure enough space between the unit and the *Selection of INSTALLATION positions for outdoor unit** To install the outdoor unit at the places which can stand the load of the machine weight and will not cause big vibrations and noises;* To install the unit at the places not to be exposed to rain or direct sunshine, and the places with good ventilation;* The noises generated from the unit will not affect the neighboring places;* Do not install the unit on non-metal frame;* Not to install the unit at the places where there might occur the generation, inflow, stay orleakage of inflammable gases;* Pay attention to the drainage of the condensed water from the base plate during operations;* To avoid the air outlet being directly against the space requirements around the outdoor unit1.
5 When there are obstacles abovethe unit2. When the front (air outlet) is open3. When there are obstacles only inthe front (air outlet)4. When there are obstacles at the front and rear When there are obstacles all aroundthe unit on four the top side is open, theinstallation is not to be done if thereare obstacles all for maintenanceShown as in the following figure. Keepthe maintenance space in front of (1'8") min100mm(4") min500mm(1'8") min200mm(8") min500mm(1'8") min 500mm(1'8")min200mm(8")minSpace for maintenance* At least two sides shouldbe kept (8") min300mm(1') min1000mm(3'4") min100mm(4") minINSTALLATION & REPAIR GUIDES plit Wall- mounted air conditioner3* INSTALLATION fixture of indoor unit* INSTALLATION & REPAIR GUIDES plit Wall- mounted air conditionerPipelines can be connected in the directions of**and* as indicated in When the pipelinesare connected to the directions of**and*, a groovefor the pipes has to be opened at the proper place onthe base stand.
6 *Rear outlet*Left rear outlet*Left outlet*Right outlet*Bottom of wall-mounting plateFix the wall-mounting plate firmly on the wall with sure of the leveling of the plate. Slanted wall-mountingplate might jeopardize the smooth discharge of the holes on the of drain pipeInstall the pipelines of the indoor unit in accordance withthe direction of the wall holes. Wrap tightly the drain pipeand the pipelines with tape. Make sure that the drain pipeis underneath the pipelines. ( ) (When the drain pipepasses the room interior, some condensed water mightoccur to its surfaces if the humidity is very high). of indoor unitPass the connection wires, connecting pipelines and drainpipe through the wall hole.
7 Hang the indoor unit on thehooks at the top of the wall-mounting plate so that thehooks at the bottom of the indoor unit match the hooks ofthe wall-mounting plate. ( ) with a tapeWall capWall pipeInteriorExterior5-10mm lower(1/5-2/5") of indoor unitDrain pipeRear pipeBottom hooksHook supportsTop holes at places slightly below the wall-mounting plate,with hole diameter of 65mm(2-3/5") and the outer edge ofthe hole 5-10mm(1/5-2/5") lower ( ) so that the condensedwater can smoothly flow out. Cut the wall penetrating pipeto proper length according to the thickness of the wall (3-5mm(1/10-1/5") longer than the wall thickness) and insertthe pipe as indicated in * INSTALLATION fixture of outdoor unit* INSTALLATION & REPAIR GUIDES plit Wall- mounted air conditionerInspections:a.
8 Check if the hooks at the top and bottom are firmly Check if the position of the master unit is properly The drain pipe should not curve upward ( ).d. The drain pipe should be at the lower part of the wall pipes (Fig. 5).Drain pipeConnecting wiresConnecting pipeWall pipeDrain * Try to ship the product to the INSTALLATION location in its original package;* As the gravity center of the unit is not at the INSTALLATION center, special caution should be takenwhen using hoisting cables to lift it up;* During shipping, the outdoor unit must not be slanted to over 45 degrees (Do not store the unitin a horizontal way).* Use expansion bolts to fix the mounting supports on the wall;* Use bolts and nuts to fix the outdoor unit firmly on the supports and keep on the same level.
9 * If the unit is installed on the wall or at the rooftop, the supports have to be firmly fixed so as toresist earthquake or strong for parallel units installations300mm(1')min*Ordinary pipelines connection & Air purging **Ordinary pipelines connectionNo dust ,foreign articles,air or moisture should be allowed to enter the air conditioning should be paid when pipeline connection for outdoor unit is to avoid repeatedcurves as much as possible,otherwise hardening or cracks might be caused to the copper wrenches should be used when the pipeline connection is done so as to ensure appropriatetorque(refer to following torque Table 1).Excessive torque might damage the joints while too littletorque might lead to leakage.
10 * The following ordinary pipelines connection and air purging procedures are justsuitable for non-quick coupler & REPAIR GUIDES plit Wall- mounted air conditionerTable 1 Torque based upon the wrench to be used*Air purging with vacuum that pipelines connection have been properlyconnected,remove t he charging port cap,and connectthe manifold gauge and the vacuum pump to thecharging valve by service hoses as shown the valve of the l ow p ressure side of manifoldgauge,then,run the vacuum the indoorunit and the connecting pipes until the pressure inthem lowers to below (The operation timefor vacuuming is about 10 minutes).When the desiredvacuum is reached,close the valve of the low pressureof the manifold and stop the vacuum the service hoses and fit the cap tothe charging t he blank c aps,and fully open the spindlesof the 2-way and 3-ways valves with a service the blank caps of the 2-way and 3-waysvalves,applying the above torque Table unitOutdoor unitPressure gaugeManifold gaugeVacuum pumpUnion nutBlank capValve stemCharging portService hose*Adding refrigerantRefrigerant must be added if t he piping measures morethan mtrs(25'0 ) in operation can onlybe performed by a professional technician,for theadditional amount,see the table 2 valve3-way valveOuter diameter ofcopper pipeTightening (1/4")