1 INSTALLATION INSTRUCTIONS . AND. OWNER'S MANUAL . VENTED. ROOM HEATER. MODELS. RH-50-6 RH-65-6. RH-50C-1 RH-65C-1. RH-50-6 Shown WARNING: If the information in these instruc- tions are not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use gasoline or other flamma- ble vapors and liquids in the vicinity of this or any other appliance. Installer: Leave this MANUAL with the appliance. WHAT TO DO IF YOU SMELL GAS Consumer: Retain this MANUAL for future Do not try to light any appliance. reference. Do not touch any electrical switch; do not use any phone in your building . Immediately call your gas supplier from a WARNING: If not installed, operated and main- neighbor's phone. Follow the gas suppli- tained in accordance with the manufacturer's in- er's INSTRUCTIONS . structions, this product could expose you to sub- If you cannot reach your gas supplier, call stances in fuel or from fuel combustion which can the fire department.
2 Cause death or serious illness. INSTALLATION and service must be performed by a qualified installer, service agency or the gas supplier. Page 1. TABLE OF CONTENTS. SECTION PAGE. Important Safety Safety Information for Users of LP Gas Vent Safety Shutoff Reversible Vertical or Horizontal Thermostat Lighting Pilot Flame Main Burner Flame Parts List RH-50 & Parts View RH-50 & Parts List RH-50C & Parts View RH-50C & Optional Blower INSTALLATION 16-17. Master Parts Distributor How To Order Repair Service Page 2 12822-5-0709. IMPORTANT SAFETY INFORMATION. THIS IS A HEATING APPLIANCE. DO NOT OPERATE THIS APPLIANCE WITHOUT FRONT PANEL INSTALLED. Due to high temperatures, the room heater should be DO NOT put anything around the heater that will ob- located out of traffic and away from furniture and drap- struct the flow of combustion and ventilation air. See eries. clearances. Children and adults should be alerted to the hazards of DO keep the appliance area clear and free from combus- high surface temperature and should stay away to avoid tible material, gasoline and other flammable vapors and burns or clothing ignition.
3 Liquids. Young children should be carefully supervised when they DO examine burners periodically. Clean and replace are in the same room as the room heater. damaged parts. Clothing or other flammable material should not be placed DO NOT use this heater if any part has been under water. on or near the room heater. Immediately call a qualified service technician to inspect the heater and to replace any part of the control system Due to high surface temperatures, keep children, clothing and any gas control which has been under water. and furniture away. WARNING: Any change to this room heater or its controls Keep burner and control compartment clean. can be dangerous. Any safety screen or guard removed INSTALLATION and repair should be done by a QUALIFIED for servicing a room heater must be replaced prior to SERVICE PERSON. The room heater should be inspected operating the room heater. before use and at least annually by a qualified service person.
4 More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that control compartments, burners and circulating air passageways of the room heater be kept clean. 12822-5-0709 Page 3. SAFETY INFORMATION FOR USERS OF LP-GAS. Propane (LP-Gas) is a flammable gas which can cause fires point with the members of your household. Someday, when and explosions. In its natural state, propane is odorless and there may not be a minute to lose, everyone's safety will de- colorless. You may not know all the following safety precau- pend on knowing exactly what to do. If, after reading the fol- tions which can protect both you and your family from an ac- lowing information, you feel you still need more information, cident. Read them carefully now, then review them point by please contact your gas supplier. LP-GAS WARNING ODOR. If a gas leak happens, you should be able to smell the gas because of the odorant put in the LP-Gas.
5 That's your signal to go into immediate action! Do not operate electric switches, light matches, use your Use your neighbor's phone and call a trained LP-Gas service phone. Do not do anything that could ignite the gas. person and the fire department. Even though you may not Get everyone out of the building vehicle, trailer, or area. Do continue to smell gas, do not turn on the gas again. Do not that IMMEDIATELY. re-enter the building , vehicle, trailer, or area. Close all gas tank or cylinder supply valves. Finally, let the service man and firefighters check for escaped LP-Gas is heavier than air and may settle in low areas such gas. Have them air out the area before you return. Properly as basements. When you have reason to suspect a gas leak, trained LP-Gas service people should repair the leak, then keep out of basements and other low areas. Stay out until check and relight the gas appliance for you. firefighters declare them to be safe.
6 NO ODOR DETECTED - ODOR FADE. Some people cannot smell well. Some people cannot smell the The odorant in escaped gas can adsorb or absorb onto or into odor of the chemical put into the gas. You must find out if you walls, masonry and other materials and fabrics in a room. That can smell the odorant in propane. Smoking can decrease your will take some of the odorant out of the gas, reducing its odor ability to smell. Being around an odor for a time can affect your intensity. sensitivity or ability to detect that odor. Sometimes other odors LP-gas may stratify in a closed area, and the odor intensity could in the area mask the gas odor. People may not smell the gas odor vary at different levels. Since it is heavier than air, there may be or their minds are on something else. Thinking about smelling a more odor at lower levels. Always be sensitive to the slightest gas odor can make it easier to smell. gas odor.
7 If you detect any odor, treat it as a serious leak. Im- The odorant in LP-gas is colorless, and it can fade under mediately go into action as instructed earlier. some circumstances. For example, if there is an underground leak, the movement of the gas through soil can filter the odorant. Odorants in LP-gas also are subject to oxidation. This fading can occur if there is rust inside the storage tank or in iron gas pipes. SOME POINTS TO REMEMBER. Learn to recognize the odor of LP-gas. Your local LP-Gas to set too long before refilling. Cylinders and tanks which Dealer can give you a Scratch and Sniff pamphlet. Use it have been out of service for a time may develop internal rust to find out what the propane odor smells like. If you suspect which will cause odor fade. If such conditions are suspected that your LP-gas has a weak or abnormal odor, call your LP- to exist, a periodic sniff test of the gas is advisable.
8 If you gas dealer. have any question about the gas odor, call your LP-gas If you are not qualified, do not light pilot lights, perform dealer. A periodic sniff test of the LP-gas is a good safety service, or make adjustments to appliances on the LP-gas measure under any condition. system. If you are qualified, consciously think about the If, at any time, you do not smell the LP-gas odorant and you odor of LP-gas prior to and while lighting pilot lights or think you should, assume you have a leak. Then take the same performing service or making adjustments. immediate action recommended above for the occasion when Sometimes a basement or a closed-up house has a musty you do detect the odorized LP-gas. smell that can cover up the LP-gas odor. Do not try to light If you experience a complete gas out, (the container is pilot lights, perform service, or make adjustments in an area under no vapor pressure), turn the tank valve off immediately.
9 Where the conditions are such that you may not detect the If the container valve is left on, the container may draw in odor if there has been a leak of LP-gas. some air though openings such as pilot light orifices. If this Odor fade, due to oxidation by rust or adsorption on walls occurs, some new internal rusting could occur. If the valve is of new cylinders and tanks, is possible. Therefore, people left open, then treat the container as a new tank. Always be should be particularly alert and careful when new tanks or sure your container is under vapor pressure by turning it off cylinders are placed in service. Odor fade can occur in new at the container before it goes completely empty or having tanks, or reinstalled old tanks, if they are filled and allowed it refilled before it is completely empty. Page 4 12822-5-0709. INTRODUCTION. Introduction The base referred to above does not mean the fire-proof base as Always consult your local building Department regarding regu- used on wood stoves.
10 The protection is primarily for rugs that may lations, codes or ordinances which apply to the INSTALLATION of a be extremely thick and light-color tile that can discolor. vented room heater. Floor pad is available from Empire Comfort Systems, Inc., Part INSTRUCTIONS to Installer Number RH-425. 1. Installer must leave instruction MANUAL with owner after instal- Qualified Installing Agency lation. INSTALLATION and replacement of gas piping, gas utilization equip- 2. Installer must have owner fill out and mail warranty card ment or accessories and repair and servicing of equipment shall be supplied with heater. performed only by a qualified agency. The term qualified agency . 3. Installer should show owner how to start and operate heater means any individual, firm, corporation, or company which whether and thermostat. in person or through a representative is engaged in and is respon- General Information sible for (1) the INSTALLATION or replacement of gas piping or (b) the This series is design certified in accordance with American National connection, INSTALLATION , repair or servicing of equipment, who is Standard/CSA Standard and CSA by the Canadian experienced in such work, familiar with all precautions required Standards Association, as a Vented Room Heater and must be and has complied with all the requirements of the authority having installed according to these INSTRUCTIONS .