INSTALLATION MANUAL - Farnell element14

INSTALLATIONMANUALSECURIT 800L+ CONTROL PANELST800L+2 CONTENTSWARNINGS3 STANDARDS3 WARRANTY STATEMENT3 PRODUCT DESCRIPTION3 AVAILABLE PARTS3 INTENDED USE3 SPECIFICATIONS4 INSTALLATION5 Mounting5 Wiring the Control Panel5 Mounting a Remote Keypad7 Wiring a Remote Keypad7 POWERING UP7 Initial Power Up7 PROGRAMMING8 Exit Time8 Entry Time8 Sounder Duration9 Night Set/Home Set Exit Time9 Circuit Programming10 Extended Programming Options10 Home Set Zone Selection10 Engineer Access Code11 Engineer Event Log Review11 Engineer Test Options11 Factory Programming Defaults12 GLOSSARY OF TERMS12 SOUNDER CONNECTIONS14 FAULT FINDING15 GENERAL QUESTIONS & ANSWERS153 WARNINGSP rolonged short circuit of any supply can cause damage to the the necessary precautions in not allowing liquids to spill on or into the unit conforms to ECD 89/336/EEC & LVD 73/23/EEC.

6 Detector reset (L+ when programmed for ID) Some detectors require the removal of power to reset (such as Viper Plusfi or Smoke detectors). You can program the L+ terminal to be used as an ID

Tags:

  Manual, Installation, Smoke, Installation manual

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of INSTALLATION MANUAL - Farnell element14

1 INSTALLATIONMANUALSECURIT 800L+ CONTROL PANELST800L+2 CONTENTSWARNINGS3 STANDARDS3 WARRANTY STATEMENT3 PRODUCT DESCRIPTION3 AVAILABLE PARTS3 INTENDED USE3 SPECIFICATIONS4 INSTALLATION5 Mounting5 Wiring the Control Panel5 Mounting a Remote Keypad7 Wiring a Remote Keypad7 POWERING UP7 Initial Power Up7 PROGRAMMING8 Exit Time8 Entry Time8 Sounder Duration9 Night Set/Home Set Exit Time9 Circuit Programming10 Extended Programming Options10 Home Set Zone Selection10 Engineer Access Code11 Engineer Event Log Review11 Engineer Test Options11 Factory Programming Defaults12 GLOSSARY OF TERMS12 SOUNDER CONNECTIONS14 FAULT FINDING15 GENERAL QUESTIONS & ANSWERS153 WARNINGSP rolonged short circuit of any supply can cause damage to the the necessary precautions in not allowing liquids to spill on or into the unit conforms to ECD 89/336/EEC & LVD 73/23/EEC.

2 It has been tested and proven tomeet all current emission and immunity regulations as set out by the EEC. This unit complieswith BS4737 part 1 1988 which relates to security control STATEMENTC & K Systems offers a two and a half year warranty from the date of manufacture for for some reason the unit fails in the first six months, C & K will replace the unit free of it fails in the remaining two years, return the unit to C & K systems, and we will test the unit. Ifit is found customer damaged, a charge will incur. Otherwise the unit will be repaired andreturned free of DESCRIPTIONThe Securit 800L+ is an 8-zone programmable microprocessor control panel using state of theart technology and manufacturing techniques.

3 The control panel has many advanced featuresthat can only be found in more expensive control panels. These features include two usercodes, Chime, Fire, and Keypad PA. Many options in the programming functions allow thecontrol panel to be versatile and user friendly. This panel is the ideal choice for residential andlight commercial PARTSThe following selection of spares and extras are available: Remote Keypad - giving full control over the control panel. Spare PCB - for replacement in the event of failure. Keyswitch - giving simple set/unset can obtain these items from your original place of USEThis control panel is designed to be used in residential and light commercial applications suchas homes, small shops, and so following information explains the specifications of the FOR SOFTWARE REVISION NUMBER software revision number is located on the top of the main SupplyMains Supply Voltage230 V AC NominalPSU output V NominalMaximum output current1 A (total)Aux.

4 Current500 mA Fuse1 A (20 mm)Panel Quiescent40 mAKeypadsSupply VQuiescent Current20 mAActive45 mAMaximum number allowed6 GeneralFor internal use onlyNormal operating temperature 0 C to 40 CHumidity10 to 90% non condensingDimensions263 mm (W) 223 mm (H) 82 mm (D)Control Panel kg Excluding BatteryStand by max. valnve regulated lead acidStandby Time (load dependent) 24 hrs with hrs with nom. based on(panel+keypad+2*PIR=40+20+25+25mA)Cabl e run per zone/circuit100m max with 50mA loadCable run (alarm sounder)50m max with 7 cable100 max with 16 or 7 paralleledFactory DefaultsUser/customer Code 11234 User/customer Code 2 Disabled (0000)Engineer Code7890 Circuit 1 Entry Circuit.

5 (Fixed)Circuit 2 Alarm Circuit isolated in Night 3 Alarm 4 Alarm 5 Alarm 6 Alarm 7 Alarm (Personal Attack)Full Set Exit Time30 SecondsNight set Exit Time15 SecondsEntry time30 SecondsSounder Ring Time15 MinutesChimesDisabledPROCESSORVERSIONPOW ERSUPPLYKEYPADSGENERALFACTORYDEFAULTS5 INSTALLATIONL ocate the control panel out of sight, such as in a hall, or under stairs or acupboard, where connection is easy and the detector zone and mains cablescan be concealed. Avoid areas subject to high temperature or humidity, suchas next to a boiler/heater, in an airing-cupboard, or fitting the keypad(s), site them where they are not visible fromoutside, but where there is adequate light and accessibility for the the lid screws and the the printed circuit board (PCB) or keypad the panel in the selected position and mark three fixing the panel securely using all three mounting hole tamper spring and mount PCB onto the support : for Mounting Remote Keypad see page THE CONTROL PANELWARNING MAINS CONNECTIONThe panel must be permanently connected to the mains supply inaccordance with current IEE wiring regulation.

6 A 5 amp fused spur,installed by a qualified electrician, is strongly recommended. Any faultwhich could be mains related must be diagnosed and corrected by aqualified electrician to ensure continued safe : Under certain circumstances the transformer metalworkcan reach 70 C. This is normal and well within prescribed ConnectionMaximum battery size is 12V panel requires a standby battery to be fitted to provide power in theevent of mains failure. A valve regulated lead acid battery must be CircuitsConnections are provided for up to eight detector circuits of which normallyclosed detection devices must be used. A common tamper loop is providedfor all detection devices marked as 24 HR Tamper.

7 One or more devicesmay be connected to each alarm circuit. These should be connected in aseries configuration. These circuit connections are located to the bottomright of the PCB (see Diagram B).PIR Latch Line (L+)In the event of two or more detectors (motion sensors or glassbreakdetectors) being fitted to any single zone, latching detectors should beused. The L+ connection provides this function. It is low (0 V) when unsetand high (12 V) when set. It should be connected to the appropriate SET orLATCH terminal in your detector. See glossary for LINEDESCRIPTION6 Detector reset (L+ when programmed for ID)Some detectors require the removal of power to reset (such as Viper Plus or smoke detectors).

8 You can program the L+ terminal to be used as an IDoutput using option 7-4. The L+ terminal should then be used as thenegative supply for these devices. The positive supply should be taken fromthe AUX +.Internal Sounders, Speakers, Strobe and Keyswitch WiringDETECTORRESETE xternal Sounder & StrobeDiagram A shows the connection for external sounder and strobe. Pleasenote that the sounder trigger is applied negative (Negative ring).ST-Strobe switched negative -Sounder switched negative trigger+Sounder hold off/strobe positive hold off supply & sounder tamper feed (negative).-RSounder tamper return (negative).AUX DC - Detector powerThe auxiliary power is provided from connections marked AUX.

9 This is toprovide the 12 V supply for detectors such as movement or glassbreakdetectors. The auxiliary power output is rated at 500 mA max (12 VCDnominal). (See Diagram B.)INTERNALDEVICESEXTERNALDEVICESAUXILIA RYPOWERBASIC BOARDLAYOUTD iagram BDiagram AKeyswitch ConnectionsOpen = ONClosed = OFFOFFONA maximum of two 16 ohm speakersmay be fitted in A REMOTE KEYPAD1 Choose the keypad location, and then mark holes for sure the cable is run through the the backbox in the selected position, making sure the cable isnot A REMOTE KEYPADUse 6 core cable for connection of all remote the cable into the terminals shown in Diagram C, making sure eachwire goes to a like-named terminal in the panel.

10 C goes to C, D to D, + to +and - to -. Wire the tamper wires in series with your existing tamper do not need to identify individual keypads to the system. If you usemore than one remote keypad, either wire it back to the control panel ordaisy-chain it from another keypad. Wire all connections in parallel with theexception of the tamper circuit which you MUST wire in series. (See theGlossary for series and parallel examples.)POWERING UPINITIAL POWER UPNote: Keep the lid off the main control panel in order to enter engineermode. Alternatively, you can enter 7890 # to enter engineer the mains supply ON. The internal sounder then denotes a tamper 1 2 3 4 followed by the # (hash) button.