LaneMinder 2 Power ONHigh IntensityLED ArrayLANES- Push Button for lanemaintenance timer (adjustable)Disables LaneMinder and automaticallyrestarts after time Push Button for pin in gutter timer (adjustable)Disables LaneMinder and automaticallyrestarts after time 1 TransmitterBEAM 2 ReceiverBEAM 1 ReceiverBEAM 2 Push ButtonSwitchREAR PANELS ocket for 12 VDCP ower SupplyLaneMinder 2 LANESPINPOWERRESETALARMPINLANEBEAM 2 RxBEAM 2 RxBEAM 2 TxBEAM 2 TxBEAM 1 RxBEAM 1 RxBEAM 1 TxBEAM 1 TxEXTBUZZEREXTBUZZERCUTOUT12 VDCR egulated 12 VDC DC socket(centre poleis positive)RJ45 connectorfor optional machineor IR cut-out(s)12 VDC signalfor optionalexternal alarm buzzerRJ-45 connector forBEAM 1 RECEIVERRJ-45 connector forBEAM 1 TRANSMITTERRJ-45 connector forBEAM 2 RECEIVERRJ-45 connector forBEAM 2 TRANSMITTERA djuster forALARM timeAdjuster forLANES time-outAdjuster forPIN time-outLANEAREALANEAREAP ress to shut off beam for 20 secondsto enable staff to pass by without setting off flashes during this Tx and Rx units between 5 and 15 feetdown the lane at a height of about 18 inches(so lane machine will go under withoutbreaking the beam)BEAM 2 is optionalBEAM 2 is normally placed at about 50 to 55 feet down the lanesand acts to trigger the CUT-OUTs if BEAM 1 has been : BEAM 1 and BEAM 2 must be broken in sequence to trigger BEAM 2 only is broken, nothing the standard LaneMinder 2 software automatically detects Beam 2when it is plugged Beam 2 option ca

Cutout-2 Module Cutout Control Module One module per pair of lanes is required to shut down machines when LaneMinder Beam 2 is broken in sequence after Beam 1.

Tags:

  Cybernetics, Laneminder 2, Laneminder

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Installation Notes: LaneMinder 2 - cybernetic.com.au

1 LaneMinder 2 Power ONHigh IntensityLED ArrayLANES- Push Button for lanemaintenance timer (adjustable)Disables LaneMinder and automaticallyrestarts after time Push Button for pin in gutter timer (adjustable)Disables LaneMinder and automaticallyrestarts after time 1 TransmitterBEAM 2 ReceiverBEAM 1 ReceiverBEAM 2 Push ButtonSwitchREAR PANELS ocket for 12 VDCP ower SupplyLaneMinder 2 LANESPINPOWERRESETALARMPINLANEBEAM 2 RxBEAM 2 RxBEAM 2 TxBEAM 2 TxBEAM 1 RxBEAM 1 RxBEAM 1 TxBEAM 1 TxEXTBUZZEREXTBUZZERCUTOUT12 VDCR egulated 12 VDC DC socket(centre poleis positive)RJ45 connectorfor optional machineor IR cut-out(s)12 VDC signalfor optionalexternal alarm buzzerRJ-45 connector forBEAM 1 RECEIVERRJ-45 connector forBEAM 1 TRANSMITTERRJ-45 connector forBEAM 2 RECEIVERRJ-45 connector forBEAM 2 TRANSMITTERA djuster forALARM timeAdjuster forLANES time-outAdjuster forPIN time-outLANEAREALANEAREAP ress to shut off beam for 20 secondsto enable staff to pass by without setting off flashes during this Tx and Rx units between 5 and 15 feetdown the lane at a height of about 18 inches(so lane machine will go under withoutbreaking the beam)BEAM 2 is optionalBEAM 2 is normally placed at about 50 to 55 feet down the lanesand acts to trigger the CUT-OUTs if BEAM 1 has been : BEAM 1 and BEAM 2 must be broken in sequence to trigger BEAM 2 only is broken, nothing the standard LaneMinder 2 software automatically detects Beam 2when it is plugged Beam 2 option can be added at any timeRESET cancels all+-+ Installation Notes.

2 86 Barry StreetReservoirVictoria 3073 AustraliaPhone +61 3 9460 2559 Fax +61 3 9460 7071 Page 1 of Cybernetic SolutionsAdjustmentsOperationInstallatio nMount IR Transmit and Receive modules on walls or posts at opposite ends of the LANE AREA between 5 and 15 feetdown the lanes at a height of about 18 inches to 2 feet above the lane the LaneMinder control box at the main reception counter or other suitable supplied CAT-5 cables and joiners to connect the IR Transmit and Receive modules to the correct sockets onthe rear of the LaneMinder control box. (When only one beam is being used, connect to Beam 1).Plug the 12 VDC power supply into the rear of the LaneMinder control box, plug into a wall outlet and turn the IR Transmit and IR Receive modules are aligned correctly (see additional sheet for alignment instructions)the LEDs on the modules will be ON. If the LEDs are FLASHING, this means that the beams are not aligned or that thecontrol unit is not receiving the beam detected the LaneMinder is, theon the control box and thes on the Transmit and Receive modulesare.

3 This is known the beam is broken -Control unit - warning buzzer sounds andTransmit and Receive modules - warning buzzer sounds : Pressing the PIN button shuts the beam off for approximately(adjustable)to allow staff to go down the lane to attend to escaped pins etc without setting off the on Transmit and Receive modules will go out and then start flashing 30 seconds before timeperiod the end of the time period, the LaneMinder automatically resets : Pressing the LANE button shuts off the beam for approximately(adjustable)to allow staff to perform lane maintenance without setting off the LaneMinder . LEDs on the Transmitand Receive modules will go out and then start flashing 60 seconds before the end of the time the end of the time period, the LaneMinder automatically resets : Pressing theon top of either of the Transmit or Receive modules will shut the beam off forapproximately(automatically doubles to 40 seconds when Beam 2 is plugged in) to allow staff to walkdown the side aisles of the centre without setting off the LaneMinder .

4 Theon the Transmit and Receive moduleswillfor this time priority -over-rideswhich LEDLEDONDETECTALARM MODELED array flashesLEDONPIN2 minutesDETECTLANE20 minutesDETECTAISLERED button20 secondsLEDsflashLANEPINAISLERESET cancels ALLI nfra-Red beam alignment and adjustment - refer to beam unit manufacturer s instructions included in the LaneMinder 2 -PIN -LANE -Optional: Provides amode if tripped and will shut downthe Pinspotters or normally situated about 50 to 55 feet down the lane area and must be broken in sequence afteris broken to perform its will not is signified by 2 and CUTOUT MODULES secondary ALARMBEAM 2 BEAM 1 BEAM 2 ALARM secondary ALARM faster ALARM signalCUTOUT MODULE interface: Allows LaneMinder towith Pinspotter, Pinsetter or IR (infra-red) triggersto shut them down for safety reasons if both BEAM 1 and BEAM 2 are broken in modules are available in 8 lane and 2 lane 2 RxBEAM 2 RxBEAM 2 TxBEAM 2 TxBEAM 1 RxBEAM 1 RxBEAM 1 TxBEAM sec to 15 sec to 4 sec to 40 minADJUSTING POTS are 20 TURNSCLOCKWISE INCREASES TIMEANTI-CLOCKWISE DECREASES TIMEFACTORY SETTING is about 10 TURNS (1/2 way)(centre poleis positive)+ 2 LANESPINPOWERRESETCONTROL DESKLANE AREAFOUL LINEAPPROACH AREACURTAIN WALL5 to 15 ftfromFOUL LINE50 to 55 ftfromFOUL LINEMACHINE AREABEAM 2 BEAM 12CC2222222216 LANE EXAMPLE116 BEAM 2 Kit with Cutout-2 Modules(to shut off lanes in pairs)

5 Cutout-2 Modules are fitted, one per pair of lanes in conjunction with a Cutout Control Cutout Control Module incorporates a status display and a remote RESET and LANE Cutout-2 Module incorporates a separate latching relay for each lane of a the Managers Control or Mask Switch circuit to the Cutout-2 Module so that the LaneMinder 2can immediately switch off the machines if Beam 2 is broken in sequence after Beam RESET will return LaneMinderand Cutout Modules to STANDBY condition,and Pinspotters/Pinsetters will turn back :Each Cutout-2 Module and the Cutout Control Moduleis powered by regulated Cutout-2 Module gets its power from theCat-5 cable when connected, daisy-chain style to theCutout Control supplemental power supply is required to be connectedto the Cutout Control Module where more than12 Cutout-2 Modules are connected in the Control ModuleCutout-2 ModuleOne module per pair of lanes is required to shut down machineswhen LaneMinder Beam 2 is broken in sequence after Beam male 1/4 push-on terminals on the board make it easyto connect either the Managers Control or Mask Switch Cutout-2 module connects in series in either circuit and theon board relay will open the circuit, shutting down the machinewhen the LaneMinder goes to its secondary ALARM Cutout-2 Module is powered from the 12 VDC which ispresent in the Cat-5 cable.

6 Additional power source is required ifmore than 12 Modules are being Cutout modules togetherTo nextShuts down 2 machinesShuts down 2 machinesCUTOUT-2 ModuleShowing Remote Control Module and keyfobsBuzzer ModuleBuzzer Modules can be added to the LaneMinder system as modules are controlled and powered by either the Cat-5 cableor the 12 VDC output line (EXT BUZZER on the rear of the LaneMinder 2 Control Module.)BEAM 2 Kit with Cutout-2 Modules(to shut off lanes in pairs)ReceiverBEAM 2 ReceiverBEAM 1 TrasnsmitterBEAM 2 TransmitterBEAM 1 LANEAREALANEAREACUTOUT-2 ModuleManagers control or mask switchcircuit is routed through CUTOUT-2 Module in series to shut down machineControl Module at Front DeskMask UnitsOne module required for LaneMinder installations where morethan one Cutout-2 Module is used or where Remote Contol is module also incorporates a LANE and a RESET button,duplicating those functions on the Control suggested mounting place for this module is adjacent to the mostoften used access door between the backend and the lane Cutout Control Module is the first module in the Cutoutdaisy chain from the main Control Module.

7 It is powered by 12 VDCdown the line via the Cat-5 12 VDC is required where more than 12 Cutout Modulesare being LED - indicates STANDBY, where machines are allowed to FLASHING LED indicates LaneMinder second ALARM has beenactivated and Cutout circuit has been or Pinspotters have been shut 2 LANESPINPOWERRESETCONTROL DESKLANE AREAFOUL LINEAPPROACH AREACURTAIN WALL5 to 15 ftfromFOUL LINE50 to 55 ftfromFOUL LINEMACHINE AREABEAM 2 BEAM 188816 LANE EXAMPLE116 BEAM 2 Kit with Cutout-8 Modules(to shut down machines in groups of 8)Cutout-8 Modules are fitted in conjunction with or in place of the original 8 lane distribution boxesthat are situated on the curtain wall of many bowling centresThe Cutout-8 Module incorporates a separate latching relay for each lane of a group of the Managers Control or Mask Switch circuit to the Cutout-8 Module so that theLaneMinder 2 can immediately switch off the machines if Beam 2 is broken in sequence after Beam optional Cutout Control Module can be fitted as first device in the is necessary if the remote control module is to be RESET will return LaneMinderand Cutout Modules to STANDBY condition,and machines will turn back.

8 Each Cutout-8 Module is powered by regulated module can be connected to a different sourceof power or can be connected, daisy-chain style,to a single power Control ModuleCutout Control ModuleOne module required for LaneMinder installations where morethan one Cutout-2 Module is used or where Remote Contol is module also incorporates a LANE and a RESET button,duplicating those functions on the Control suggested mounting place for this module is adjacent to the mostoften used access door between the backend and the lane Cutout Control Module is the first module in the Cutoutdaisy chain from the main Control Module. It is powered by 12 VDCdown the line via the Cat-5 12 VDC is required where more than 12 Cutout Modulesare being LED - indicates STANDBY, where machines are allowed to FLASHING LED indicates LaneMinder second ALARM has beenactivated and Cutout circuit has been or Pinspotters have been shut nextControls any number of Cutout-2 or Cutout-8 modulesCutout-8 ModuleOne module per 8 lanes is required to shut down machines whenLaneMinder Beam 2 is broken in sequence after Beam Cutout Control Module can be added to the circuit to enablea remote RESET and LANE button to be module is most suitable where there are existing 8 laneManagers Control distribution boxes mounted on the curtain module can mount adjacent or even replace the distribution Cutout-8 Module is powered by 12 VDC (plug pack supplied).

9 The power cable is daisy-chained from unit to unit along withthe Cat-5 communication the Module is RESET after a shut-down, the relays turn themachines back on in a staggered fashion - 1 then 2 then 3 etcwith approx second delay between Moduleplugs in hereReceiverBEAM 2 ReceiverBEAM 1 TrasnsmitterBEAM 2 TransmitterBEAM 1 LANEAREALANEAREAC ontrol Module at Front DeskMask UnitsManagers control or mask switchcircuit is routed through CUTOUT-8 Module to shut down machineCutout-8 ModuleCutout-8 ModuleRemote Control ModuleThe Remote Control Module receiver plugs intothe Cutout Control Module on the curtain the Remote keyfobs you can control the LANESand RESET functions of the LaneMinder system fromalmost anywhere in the bowling 2 Kit with Cutout-8 Modules(to shut down machines in groups of 8)