Example: biology

Installation - RV Comfort

Note: The thermostat is designed to display temperatures from 41 F to 110 F however it will operate Set Fan Speed for Cooling Mode from -40 F to +175 F. If temperature is between -40 F and 41 F then 41 will be displayed as 1. Use the SYSTEM button to select cool option. the room temperature. Also if the temperature is between 110 F and 175 F then 110 will be 2. Pressing the MODE button will toggle through the available speeds. displayed. When temperature extremes fall outside the operating limits of the thermostat, Er . will display in the temperature space of the LCD to show that current ambient temperature COOL AUTO setting allows the fan speed to vary depending on the cooling needs.

Note: The thermostat is designed to display temperatures from 41°F to 110°F however it will operate from -40°F to +175°F. If temperature is between -40°F and 41°F then 41 will be displayed as

Tags:

  Installation

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Installation - RV Comfort

1 Note: The thermostat is designed to display temperatures from 41 F to 110 F however it will operate Set Fan Speed for Cooling Mode from -40 F to +175 F. If temperature is between -40 F and 41 F then 41 will be displayed as 1. Use the SYSTEM button to select cool option. the room temperature. Also if the temperature is between 110 F and 175 F then 110 will be 2. Pressing the MODE button will toggle through the available speeds. displayed. When temperature extremes fall outside the operating limits of the thermostat, Er . will display in the temperature space of the LCD to show that current ambient temperature COOL AUTO setting allows the fan speed to vary depending on the cooling needs.

2 This is the default setting. has exceeded thermostat capabilities. Additionally, if there is a problem with one of the remote COOL HIGH or COOL LOW setting will set the fan speed to run continuously at high or low, but the upper unit will cycle when cooling is needed. temperature sensors, Er will display on the thermostat. FAN HIGH and FAN LOW setting will set the fan to run continuously at high or low speed. The upper unit will not run to produce cooling. Setpoint is not adjustable in this mode. Note: If the system is in cooling and is programmed to have only a heating appliance connected in a zone then the thermostat will still display the room temperature in that zone.

3 But the user will OFF will turn the upper unit off for zone displayed. By continuing to press the MODE button, you can toggle through the settings for the zone displayed until you have determined the setting you desire. not be able to operate any cooling appliance in that zone because there is not one connected Setpoint is not adjustable in this mode. in that zone. Additionally, if the system is in heating and is programmed to have only a cooling 3. Once you have established the settings for Zone 1, press the ZONE button to store settings in thermostat memory and proceed to the next zone.

4 Appliance connected in a zone then the thermostat will still display the room temperature in that 4. Repeat steps for each zone. zone, but the user will not be able to operate any heating appliance in that zone because there is not one connected in that zone. Your homeowner packet should contain literature that will list Note: There is a built-in delay between Control Box what heating and cooling appliances are installed in each zone of your motor home. programming and operation of the new System Mode Zones Demand HP Jumper Operation of Unit program. (Example: changing fan speed to Off N/A 1-4 N/A N/A No units operating in this mode, LCD is displaying temperature of zone.)

5 User can toggle thru zones to see low from high, it will take approximately 10. Setpoint Buttons temperature in each zone (setpoint can't be adjusted). The Setpoint buttons are located to the right and below of the LCD display. seconds until the fan speed is changed.). Cool Cool Auto 1 4 No N/A Nothing is operating since there is no cooling demand, LCD is displaying temperature of zone The thermostat must sit idle for five These buttons adjust the desired temperature setpoint up and down. To change the setpoint press UP or DOWN once. This displays the word Set on Cool Cool Auto 1 4 Yes N/A Compressor is energized, fan is energized seconds before the signal is sent to the the LCD and puts the system in the mode to change the setpoint.

6 Then, each Cool Cool High 1 4 No N/A Fan high is energized control board. The thermostat will then send press of the UP or DOWN changes the setpoint up or down for the displayed the signal to the control board in the control Cool Cool High 1 4 Yes N/A Compressor is energized, fan high is energized zone by one degree per press of the button. box, then the signal is verified before the Cool Cool Low 1 4 No N/A Fan low is energized change is put into operation. The setpoints are not adjustable when the thermostat is turned off. Also setpoint Cool Cool Low 1 4 Yes N/A Compressor is energized, fan low is energized is not adjustable for the displayed zone when the displayed zone is set to run Fan This delay also helps to eliminate Note: Thermostat may be black Cool Fan High 1 4 N/A N/A Fan high is energized (setpoint cannot be adjusted) communication noise problems.

7 High or Fan Low in that zone, or if the displayed zone is turned to Off. Last digit represents with white markings or white Cool Fan Low 1 4 N/A N/A Fan low is energized (setpoint cannot be adjusted). The setpoints are stored permanently in memory for each zone in both heating and cooling. Note: Setting SYSTEM button to OFF position will specific model number with gray markings as shown. Cool Off 1 4 N/A N/A Nothing operational in zone (setpoint cannot be adjusted). This allows the user to switch between heating and cooling at season changes and still have shut down all unit operations.

8 Heat Elec 1 4 No Non HP Nothing is operating in this mode since there is no heating demand the same settings as the previous year. This table lists the operations of the Heat Elec 1 4 Yes Non HP Fan is energized, heat strip is energized thermostat system in each of the possible SYSTEM Button Heat Elec 1 4 No Hp Nothing is operating in this mode since there is no heating demand settings. The chart shows the operations for Caution The SYSTEM button is used to put the thermostat into either heating, Heat Elec 1 4 Yes Hp High fan energized, compressor & reversing valve energized all types of appliances possible.

9 All systems cooling or off. will not necessarily have all available This thermostat should be installed and programmed by trained technicians only. Adhere to all local Heat Gas 1 4 No N/A Nothing is operating in this mode since there is no heating demand When in OFF, the system will not operate any heating or cooling appliances. options. and national codes. Disconnect all power to the system before installing, removing, or cleaning. Heat Gas 1 4 Yes N/A Gas heat energized However, the LCD display will still show the room temperatures in each zone. Heat Off 1 4 N/A N/A Nothing operational in zone (setpoint cannot be adjusted).

10 The chart to the left shows the system When in HEAT, the system is in heating. The heating appliance selected will operate when the zone functions with the 9330-33* thermostats. Notes: Application room temperature is one degree below the desired setpoint temperature. The heating appliance 1) When 2nd or 3rd stage heating is activated, it stays on until setpoint is satified. When heating stage is running for more than 20 minutes without reaching setpoint then the next available The 9330-33* zone thermostats create a climate control system that allows the operator to control up will continue to run until the zone room temperature is one degree above the desired setpoint heating stage will be energized.