DOCUMENT 1274 REVISION B October 5, 2016 Instruction Manual PRO APF SERIES IN-PAVEMENT OMNI-DIRECTIONAL UTILITY LIGHT Eaton Crouse-Hinds Series Airport Lighting Products 1200 Kennedy Road Windsor, CT 06095 Copyright 2016 Cooper Technologies Company DOCUMENT 1274 REV. B Instruction Manual PRO APF IN-PAVEMNT OMNI-DIRECTIONAL UTILITY LIGHT ii Table of Contents 1 Revisions .. iv 2 Product Warranty .. v 3 Safety Notices .. vi Keep Away from Live Circuits .. vi RESUSCITATION .. vi 4 Safety Symbols .. vii Danger .. vii Warning .. vii Caution .. vii Warning: Notice .. vii Warning: Important .. vii 5 Recommended Test Equipment and Tools .. viii 6 General Information .. 1 General Description Taxiway Omni-Directional Light.

Fluke 287 Our recommended multimeter is the Fluke 287 with the Fluke I800 current clamp accessory. Refer to the equipment manufacturer’s manuals for the proper use, maintenance and calibration

Tags:

  Manual, Instructions, Industreis, Cooper industries, Cooper, Instruction manual, Fluke

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Instruction Manual - Cooper Industries

1 DOCUMENT 1274 REVISION B October 5, 2016 Instruction Manual PRO APF SERIES IN-PAVEMENT OMNI-DIRECTIONAL UTILITY LIGHT Eaton Crouse-Hinds Series Airport Lighting Products 1200 Kennedy Road Windsor, CT 06095 Copyright 2016 Cooper Technologies Company DOCUMENT 1274 REV. B Instruction Manual PRO APF IN-PAVEMNT OMNI-DIRECTIONAL UTILITY LIGHT ii Table of Contents 1 Revisions .. iv 2 Product Warranty .. v 3 Safety Notices .. vi Keep Away from Live Circuits .. vi RESUSCITATION .. vi 4 Safety Symbols .. vii Danger .. vii Warning .. vii Caution .. vii Warning: Notice .. vii Warning: Important .. vii 5 Recommended Test Equipment and Tools .. viii 6 General Information .. 1 General Description Taxiway Omni-Directional Light.

2 1 Table 1, Part number Explanation .. 3 Figure 1, Fixture Dimensions .. 4 7 Installation .. 5 ANSI Installation Bolt Torque and Installation Method .. 7 Heico-Lock Installation Guide (2014) .. 8 Figure 2, 19999 Installation (Lifting) Tool .. 9 8 Maintenance .. 10 General .. 10 Recommended Spares .. 10 Cleaning Lens .. 11 O-Ring Replacement .. 11 Feed-thru Replacement .. 12 Outer Lens/Heater Replacement .. 12 LED Replacement .. 13 Power Supply Replacement (Series Circuit Powered Units) .. 14 Power Supply Replacement (Voltage Powered Fixtures) .. 15 8 Inch Fixture External Gasket Replacement .. 15 Pressure Test .. 16 Cleanliness and Workmanship .. 16 Maintenance Program .. 16 9 Troubleshooting .. 18 DOCUMENT 1274 REV.

3 B Instruction Manual PRO APF IN-PAVEMNT OMNI-DIRECTIONAL UTILITY LIGHT iii Visual Inspection .. 18 Electrical Inspection, Series Circuit Powered Fixtures .. 18 Figure 3, Power Supply, Series Circuit Fixtures .. 19 Wiring Diagrams, Series Circuit Powered Fixtures .. 20 Jumper Diagram, Series Circuit Powered Fixture .. 21 Figure 4, Part Identification .. 22 10 Fixture Mounting Bolts & 2-Piece Washers .. 30 DOCUMENT 1274 REV. B Instruction Manual PRO APF IN-PAVEMNT OMNI-DIRECTIONAL UTILITY LIGHT iv 1 Revisions Rev. No. Issue/Reissue Number Letter Description Checked Approved A A216-212 Initial release PG 6/1/16 B A216-365 Page 4, Fig 852UL-AP1-XXX-12X, Added base flange diameter Z , for -12A & -12C versions & for -12B & -12D versions.

4 IM 10/5/16 DOCUMENT 1274 REV. B Instruction Manual PRO APF IN-PAVEMNT OMNI-DIRECTIONAL UTILITY LIGHT v 2 Product Warranty Warranty Refer to Eaton s Crouse-Hinds Airport Lighting Products Terms and Conditions for product specific warranty information. DOCUMENT 1274 REV. B Instruction Manual PRO APF IN-PAVEMNT OMNI-DIRECTIONAL UTILITY LIGHT vi 3 Safety Notices This equipment is normally used or connected to circuits that may employ voltages which are dangerous and may be fatal if accidentally contacted by operating or maintenance personnel. Extreme caution should be exercised when working with this equipment. While practical safety precautions have been incorporated in this equipment, the following rules must be strictly observed: Keep Away from Live Circuits Operating and maintenance personnel must at all times observe all safety regulations.

5 Do not perform maintenance on internal components or service with power ON. DANGER: DANGER DO NOT PERFORM MAINTENANCE ON INTERNAL COMPONENTS OR SERVICE WITH POWER ON. RESUSCITATION Maintenance personnel should familiarize themselves with the technique for resuscitation found in widely published manuals of first aid Instruction . DOCUMENT 1274 REV. B Instruction Manual PRO APF IN-PAVEMNT OMNI-DIRECTIONAL UTILITY LIGHT vii 4 Safety Symbols Danger DANGER: DANGER The hazard or unsafe practice will result in severe injury or death. Warning WARNING: WARNING The hazard or unsafe practice could result in severe injury or death. Caution CAUTION: CAUTION The hazard or unsafe practice could result in minor injury.

6 Warning: Notice WARNING: NOTICE Possibly dangerous situation, goods might be damaged. Warning: Important WARNING: IMPORTANT Helpful information. DOCUMENT 1274 REV. B Instruction Manual PRO APF IN-PAVEMNT OMNI-DIRECTIONAL UTILITY LIGHT viii 5 Recommended Test Equipment and Tools There is a wide variety of tools and equipment needed to safely and correctly perform airfield lighting equipment installation and maintenance. In addition to the obvious tools (screwdrivers, wrenches, etc.), there is a specialized equipment needed to do the job. Multimeter One of the most important pieces of test equipment is the Multimeter. It is used to measure voltages, currents, and resistances. Almost every single maintenance task requires the use of a multimeter at one point or another.

7 A quality meter in good repair and calibration is a must because airfield lighting power distribution equipment produces non-sinusoidal waveforms, traditional average reading meters are inaccurate and have very limited use. Checking or adjusting equipment based upon incorrect current reading may dramatically reduce lamp life and adversely affect power equipment performance. A meter with TRUE RMS measuring capability with a current clamp-on accessory is needed to accurately measure distorted or chopped waveforms. All meter manufacturers offer TRUE RMS measuring meters. The following is a short list of TRUE RMS Multimeters from fluke : Manufacturer Model Number fluke 287 Our recommended multimeter is the fluke 287 with the fluke I800 current clamp accessory.

8 Refer to the equipment manufacturer s manuals for the proper use, maintenance and calibration (if necessary) of all meters. Thread Lubricant Anti-seize (marine grade preferred, Henkel/Loctite P/N 34395 or 34026 or equal customer supplied [ ]) with a K factor of for fully coating the fixture installation bolts. Drive and Ratchet A 3/8 inch square drive socket and ratchet (use ratchet for loosening bolts only and a torque wrench to tighten), size 9/16 or 14 mm for the fixture 3/8-16 UNC hex installation (customer supplied) bolts installed into a FAA L-867 or L-868 base. Torque Wrench A calibrated torque wrench (micrometer adjustable solid audible/tactile click impulse when torque value attained with an accuracy of +/- 4%) to fit a 9/16 or 14 mm socket for drive size of the socket to tighten the fixture hex bolts per Sections and Torque wrenches: Sturtevant Richmont P/N 810748, range 100 to 600 in-lbs or equal, or Sturtevant Richmont P/N 810782, DOCUMENT 1274 REV.

9 B Instruction Manual PRO APF IN-PAVEMNT OMNI-DIRECTIONAL UTILITY LIGHT ix range 10 to 50 Nm or equal. Certificate of calibration included with suggested torque wrenches. Note, never loosen bolts with a torque wrench. Torque Screwdriver A calibrated adjustable torque screwdriver to torque the smaller internal hardware and the bottom cover external screws if the fixture is opened for maintenance. Sturtevant Richmont P/N 810568 (comes with bits [hex, slotted, Torx, Phillips, sq. recess, bit holder, socket adapter], case and certificate of calibration), range 2 to 36 in- to 4 Nm or equal. Note, never loosen screws with a torque screwdriver. Pliers Needle nose pliers for installing the extremely small header jumper onto a spare Power Supply J203 header when required, or removing the flag type fast-on terminals from the power supply.

10 Xcelite P/N NN54-2 miniature pliers, fine needle nose, ESD-Safe or equal. ESD Protection A grounded ESD Wrist Strap when working on or handling fixture power supplies or LED/Heat sink assemblies. ESD Wrist Straps, also known as anti-static Wrist Straps, are used to prevent electrostatic discharge (ESD) by safely grounding a person working with electronic equipment or at an electronic assembly facility. It consists of a band of fabric with fine conductive fibers woven into it. The fibers are usually made of carbon-filled rubber, and the strap is bound with a stainless steel clasp or plate. They a usually used in conjunction with an ESD table mat on the workbench, or a special static-dissipating plastic laminate on the workbench.