INSTRUCTION MANUAL - Elliptical

Publication: 9 2875 00 991 Revision: B 08/01 INSTRUCTION MANUALforDECS-100 digital excitation control SystemDECS-100 IntroductioniINTRODUCTIONThis INSTRUCTION MANUAL provides information about the operation and installation of the decs -100 digital excitation control system . To accomplish this, the following information is Information and Specifications&Human-Machine Interface&Functional Description&Installation&BESTCOMS Communication Software&Installation and TroubleshootingWARNING!To avoid personal injury or equipment damage, only qualified personnel shouldperform the procedures in this voltage is present at the rear panel when the unit is energized.

DECS-100 Introduction i INTRODUCTION This instruction manual provides information about the operation and installation of the DECS-100 Digital Excitation Control System.

Tags:

  Manual, System, Control, Instructions, Decs, Digital, Instruction manual, Excitation, Digital excitation control system

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of INSTRUCTION MANUAL - Elliptical

1 Publication: 9 2875 00 991 Revision: B 08/01 INSTRUCTION MANUALforDECS-100 digital excitation control SystemDECS-100 IntroductioniINTRODUCTIONThis INSTRUCTION MANUAL provides information about the operation and installation of the decs -100 digital excitation control system . To accomplish this, the following information is Information and Specifications&Human-Machine Interface&Functional Description&Installation&BESTCOMS Communication Software&Installation and TroubleshootingWARNING!To avoid personal injury or equipment damage, only qualified personnel shouldperform the procedures in this voltage is present at the rear panel when the unit is energized.

2 Rearpanel connections should be made only when the unit is MANUAL mode excitation level must be evaluated prior to enabling thisfeature. If the level of excitation current is inappropriate for the generator,severe damage to the generator may PID numbers will result in poor system performance or uploading a settings file, remove operating power from the decs -100,disconnect the field wiring from terminals F+ and F , and re-apply operatingpower to the uploading a settings file, remove operating power from the decs -100,disconnect the field wiring from terminals F+ and F , and re-apply operatingpower to the decs -100.

3 NOTEBe sure that the decs -100 is hard-wired to earth ground with no smaller than12 AWG copper wire attached to the ground terminal on the rear of the unit the unit is configured in a system with other devices, it is recommendedto use a separate lead to the ground bus from each IntroductioniiFirst Printing: March 2001 Printed in USA 2001, Basler Electric, Highland, IL 62249 USAA ugust 2001It is not the intention of this MANUAL to cover all details and variations in equipment, nor does thismanual provide data for every possible contingency regarding installation or operation.

4 Theavailability and design of all features and options are subject to modification without notice. Shouldfurther information be required, contact Basler ELECTRICROUTE 143, BOX 269 HIGHLAND, IL, 62249 , 618-654-2341 FAX 618-654-2351 CONFIDENTIAL INFORMATIONof Basler Electric, Highland, IL. It is loaned for confidential use, subject to returnon request, and with the mutual understanding that it will not be used in anymanner detrimental to the interest of Basler IntroductioniiiMANUAL REVISION HISTORYThe following information provides a historical summary of the changes made to the decs -100 INSTRUCTION MANUAL (9 2875 00 991).

5 Revisions are listed in reverse chronological Version,ECO, and DateChangeRev B, 14282, 08/01 Added Embedded Software subsection to Section 5, BESTCOMSS oftware for the Windows Operating system . Corrected variousminor errors throughout the A, 12623, 03/01In Section 5, BESTCOMS Software for the Windows OperatingSystem and Section 6, BESTCOMS Software for the Palm OS Platform, Step 2 of Installing BESTCOMS was revised to reflect theaddition of an auto-start utility for the decs -100 None, 03/01 Initial releaseDECS-100 IntroductionvCONTENTSA detailed table of contents is provided at the start of each MANUAL section.

6 The MANUAL sections areordered as 1 General 1-1 Section 2 Human-Machine 2-1 Section 3 Functional 3-1 Section 4-1 Section 5 BESTCOMS Software for the Windows Operating 5-1 Section 6 BESTCOMS Software for the Palm OS 6-1 Section 7 Maintenance and 7-1 decs -100 General InformationiSECTION 1 GENERAL INFORMATIONTABLE OF CONTENTSSECTION 1 GENERAL 1-1 MODEL AND STYLE NUMBER 1-1 Style Number .. 1-2 Operating 1-2 Generator Voltage 1-2 Generator Current 1-2 Bus Voltage Sensing (Optional).

7 1-2 Accessory 1-2 Communication 1-2 Contact Input 1-2 Common Alarm 1-3 Field 1-3 AVR Operating 1-3 FCR ( MANUAL ) Operating 1-3 Var Operating Mode (Optional).. 1-3PF Operating Mode (Optional).. 1-3 Parallel 1-3 Field Overvoltage 1-3 Field Overcurrent 1-3 Generator Overvoltage 1-3 Soft-Start Function (AVR Mode Only).. 1-3 Voltage 1-3 Metering (BESTCOMS).. 1-4 Type 1-4UL 1-4 CSA 1-4CE 1-4 FiguresFigure 1-1. decs -100 Style 1-2 Figure 1-2. Typical V/Hz 1-3 decs -100 General Information1-1 SECTION 1 GENERAL INFORMATIONGENERALThe Basler digital excitation control system ( decs -100) is an electronic, solid-state, microprocessor basedcontrol device.

8 The decs -100 regulates the output voltage of a brushless, ac generator by controlling thecurrent into the generator exciter field. Input power to the decs -100 can be from a multi-pole,high-frequency, permanent magnet generator (PMG) or from the generator output when used as aconventional, shunt-excited, excitation decs -100 is supplied in an encapsulated package designed for behind-the-panel mounting. TheDECS-100 is held in place by thread-forming screws that thread into its plastic shell.

9 Front panel indicators(LEDs) annunciate decs -100 status and system conditions. decs -100 connections are made throughquarter-inch, quick-connect terminals on the rear panel. A 9-pin DB-9 type connector on the rear panelprovides communication between the decs -100 and an IBM compatible units have the following features and control modes: automatic voltage regulation (AVR), MANUAL or field current regulation (FCR),power factor (PF) regulation, and reactive power (var) stability start and voltage buildup control with an adjustable ramp in AVR control (OEL) limiting in AVR, var, and PF control (volts/hertz) or single-phase generator voltage (RMS ) sensing/regulation in AVR bus voltage (RMS )

10 Generator current sensing for metering and regulation current and field voltage analog input for proportional remote control of the contact sensing inputs for system common output relay for alarm indication and trip protection functions (field overvoltage, field overcurrent, generator overvoltage, and loss ofsensing).CGenerator paralleling with reactive droop compensation and reactive differential compensation. CRear RS-232 communication port for personal computer communication using BESTCOMSW indows based software for fast, user-friendly, setup and control .