INSTRUCTION MANUAL FRESH-AIR PUMP MODEL 8050501

INSTRUCTION MANUAL FRESH-AIR PUMPMODEL 8050501 This MANUAL provides detailed instructions , safetywarnings and other information for users of MST sFresh-Air Pump MODEL : Do not use extension cords longer than 100 ft (30 metres) orrated less than fifteen (15) amperes when operating this device. Werecommend using a minimum 12-gauge grounded extension cord witha length not exceeding 100 feet (30 metres). Pump damage will occurand the pump s warranty will be voided if this practice is OF CONTENTSGENERAL INFORMATION ..3 WARNINGS .. AIR REQUIREMENTS ..7 ASSEMBLING THE FRESH-AIR PUMP.

3 GENERAL INFORMATION The Fresh- Air Pump is designed to intake fresh, clean air from a non-conta minated atmosphere and supply this fresh air to a continuous flow supplied air respirator.

Tags:

  Manual, Pumps, Instructions, Fresh, Instruction manual fresh air pump

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of INSTRUCTION MANUAL FRESH-AIR PUMP MODEL 8050501

1 INSTRUCTION MANUAL FRESH-AIR PUMPMODEL 8050501 This MANUAL provides detailed instructions , safetywarnings and other information for users of MST sFresh-Air Pump MODEL : Do not use extension cords longer than 100 ft (30 metres) orrated less than fifteen (15) amperes when operating this device. Werecommend using a minimum 12-gauge grounded extension cord witha length not exceeding 100 feet (30 metres). Pump damage will occurand the pump s warranty will be voided if this practice is OF CONTENTSGENERAL INFORMATION ..3 WARNINGS .. AIR REQUIREMENTS ..7 ASSEMBLING THE FRESH-AIR PUMP.

2 8 OPERATING instructions ..9-10 MAINTENANCE instructions ..11-13 TROUBLE SHOOTING PROCEDURES ..14-16 REPLACEMENT PART LISTING ..17 WARRANTY INFORMATION ..183 GENERAL INFORMATIONThe FRESH-AIR Pump is designed to intake fresh , clean air from a non-contaminated atmosphere andsupply this fresh air to a continuous flow supplied air clean air is filtered through a porous plastic intake muffler designed to protect the pump fromdust and dirt particles. The outlet air supplied to the respirator is filtered through an activatedcharcoal filter designed to remove tastes and odors from the breathing s FRESH-AIR Pump is oil-less and has rotary carbon vanes.

3 The pump does not produce carbonmonoxide, oil vapors, oil mist or moisture, however it is extremely important that the atmospherefrom which the air is drawn into the pump is clean and free of any carbon monoxide or other toxicgases or vapors. OSHA requires, per 29 CFR , the carbon monoxide in the inlet air to beless than 10 ppm, and that this condition is assured at all times. Sometimes carbon monoxidemonitoring may be required to warn a user, should the CO levels exceed the permissible FRESH-AIR Pump will supply a maximum air flow rate of ten (10) SCFM of breathing air to oneworker or a maximum supply pressure of fifteen (15) psig.

4 The user is responsible for determiningif their respirator will operate properly at these flows and pressures. USE ONLY MSHA/NIOSHAPPROVED RESPIRATORS THAT WILL OPERATE AT PRESSURES LESS THAN FIFTEEN(15) ALL instructions IN THIS MANUAL BEFORE USING THIS FRESH-AIR PUMPMODEL TO OPERATE THIS PUMP IN ACCORDANCE WITH THE INSTRUCTIONSCONTAINED IN THIS MANUAL AND ACCOMPANYING INFORMATION MAY RESULT INDEATH OR SERIOUS INJURY TO THE RESPIRATOR NOT OPERATE THIS PUMP IN AN EXPLOSIVE OR CORROSIVE NOT OPERATE THIS PUMP WHERE IT CAN BE EXPOSED TO ANY LIQUID OR DUSTYMATERIAL.

5 THIS PUMP MUST BE PROTECTED FROM THE ELEMENTS IF the pump s inlet air muffler in a clean breathable air location at all times. THIS PUMPDOES NOT REMOVE TOXIC GASES OR OTHER CONTAMINANTS FROM THE INCOMINGAIR BEING TRANSFERRED TO THE RESPIRATOR the BREATHING AIR REQUIREMENTS section of this MANUAL for specific details onbreathing air quality. THIS PUMP DOES NOT SUPPLY pump will supply a maximum air flow rate of ten (10) SCFM or a maximum supply pressureof fifteen (15) psig. USE ONLY MSHA/NIOSH APPROVED RESPIRATORS THAT WILLOPERATE AT PRESSURES LESS THAN (15) sure that the pump s outlet pressure, measured by the pressure gauge on the pump, is maintainedabove the minimum pressure setting required by the Respirator manufacturer.

6 REFER TO YOURRESPIRATOR MANUAL FOR CORRECT PRESSURE REQUIREMENTS, PERMISSIBLEHOSE LENGTHS AND FITTING TYPES. FAILURE TO COMPLY WITH THE RESPIRATORMANUFACTURER S REQUIREMENTS WILL VOID THE MSHA/NIOSH APPROVAL(S) ANDCOULD RESULT IN DEATH OR SEVERE regarding whether or not your Respirator is compatible with this pump can be directed toMST s Customer Service Department at 1-800-542-6646 or RESPIRATORS USED WITH THIS PUMP MUST NOT BE WORN IN ANYATMOSPHERE IMMEDIATELY DANGEROUS TO LIFE OR HEALTH OR FROM WHICHTHE WEARER CANNOT ESCAPE WITHOUT THE USE OF THE connecting your respirator to this device.

7 Use only the air supply hose and couplers requiredby the respirator manufacturer and approved by of non-approved hose or couplers will void the respirator s MSHA/NIOSH Approval and couldreduce the air flow to the respirator, resulting in possible death or serious injury to the your hose and couplers are not compatible with the coupler supplied on this pump, you maychange the coupler on this pump to provide the proper connection. Contact the factory with anyquestions regarding the type of fittings that can be used with this NOT modify or alter this pump in any manner.

8 Use only approved MST replacement parts andcomponents. Failure to use approved MST components and replacement parts invalidates all MSTwarranties, and may result in death or serious injury to the respirator you have any questions concerning the use of this pump or your respirator, or you are not sure theinlet muffler is in a breathable location, ask your instructions for the use and care of this product must be supplied to you by your employer asrecommended by the manufacturer and as required by Federal Law (29 CFR ).For technical assistance or additional copies of this MANUAL , call or write:MST, Box 87 Hicksville, OH 43526-00871-800-542-66461-419-542-6645 Fax: 1-419-542-6475 Email: Site: DATA:Pump Design:Rotary Carbon Vane (4 Vanes)Maximum Pressure:15 psig (103 kPa)Air Flow (Free):10 SCFM (283 lpm)Inlet Filter:Porous PlasticOutlet Filter:Activated CharcoalDIMENSIONS:Width:9" ( cm)Length:16" ( cm)Height:12" ( cm)Weight:53 lbs.

9 (approx.)(24 kg)ELECTRIC MOTOR DATA:Voltage:100-115/208-230 VACP hase:SingleCycles:50/60 HzHorsepower:3/4 RPM1725 Service @ 115 VSound Level:66 dB(A)@ 10 psiProtection:Internal Thermal OverloadApprovals:CSA (Canadian Standards Association) ApprovedSee Motor Rating Plate on Motor for Additional : PROPER MOTOR SELECTION AND WIRING (IN ACCORDANCE WITH LOCALAND NATIONAL ELECTRIC CODES) IS THE RESPONSIBILITY OF THE AIR REQUIREMENTSAIR QUALITYThe FRESH-AIR pump s inlet muffler must be located in a clean breathable air location at all breathable air drawn into the inlet muffler must meet at least the requirements for Type 1gaseous air as described in the Compressed Gas Association Commodity Specification (GradeD or higher) as specified by Federal Law (29 CFR ).

10 The requirements of Grade D breathable air (condensed)in mg/m3 of gas5 mg/m3 maximumCarbon Monoxide10 ppm maximumCarbon Dioxide1,000 ppm maximumNo toxic contaminants at levels which would make the air unsafe to to the CGA Commodity Specification for complete details. This publication is availablefrom:The Compressed Gas Association500 Fifth AvenueNew York, NY 100368 ASSEMBLING THE FRESH-AIR PUMPR emove the cardboard shipping sleeve around the pump and the gauge box. Lift the pump andattached plywood base from the box and remove pump from plywood recommends saving all packaging materials in the event that the pump must be shipped in the pressure gauge from its box and assemble it tothe gauge port located on top of the pump s filter manifoldas shown in Figure 1.