Example: quiz answers

INSTRUCTION MANUAL - Healthcare Wellness & Healthcare …

10 seriesBlood pressure Monitorwith ComFitTMCuffModelBP785 INSTRUCTION MANUALESPA OLENGLISH 2 Before Using the MonitorIntroduction ..4 Safety Information ..5 Operating the Device ..5 Risk of Electrical Shock ..7 Care and Maintenance ..7 Before Taking a Measurement ..8 Operating InstructionsKnow Your Unit ..9 Unit Display ..11 Display Symbols ..12 Irregular Heartbeat Symbol ..12 Movement Error Symbol ..12 USER ID Symbol ..12 Morning Hypertension Symbol ..13 Heartbeat Symbol ..14 Average Value Symbol ..14 Morning Average Symbol ..14 Evening Average Symbol ..14 Cuff Wrap Guide Symbol ..14 Using the AC Adapter ..15 Battery Installation ..17 Setting the Date/Time and TruRead TM ..19 Applying the Arm Cuff ..24 TABLE OF CONTENTST aking a Measurement ..28 calibration Check System ..28 Cuff Wrap Guide ..28 Using the Guest Mode ..29 Selecting the USER ID ..30 Using the USER ID.

Your new digital blood pressure monitor uses the oscillometric method of blood pressure measurement. This means the monitor detects your ... The monitor is not intended to be a diagnostic device. If battery fluid should get in your eyes, immediately rinse with ... Calibration Check System SET Button. KNOW YOUR UNIT 10 Components: Arm Cuff Air ...

Tags:

  Blood, Methods, Calibration, Pressure, Monitor, Diagnostics, Blood pressure, Blood pressure monitor

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of INSTRUCTION MANUAL - Healthcare Wellness & Healthcare …

1 10 seriesBlood pressure Monitorwith ComFitTMCuffModelBP785 INSTRUCTION MANUALESPA OLENGLISH 2 Before Using the MonitorIntroduction ..4 Safety Information ..5 Operating the Device ..5 Risk of Electrical Shock ..7 Care and Maintenance ..7 Before Taking a Measurement ..8 Operating InstructionsKnow Your Unit ..9 Unit Display ..11 Display Symbols ..12 Irregular Heartbeat Symbol ..12 Movement Error Symbol ..12 USER ID Symbol ..12 Morning Hypertension Symbol ..13 Heartbeat Symbol ..14 Average Value Symbol ..14 Morning Average Symbol ..14 Evening Average Symbol ..14 Cuff Wrap Guide Symbol ..14 Using the AC Adapter ..15 Battery Installation ..17 Setting the Date/Time and TruRead TM ..19 Applying the Arm Cuff ..24 TABLE OF CONTENTST aking a Measurement ..28 calibration Check System ..28 Cuff Wrap Guide ..28 Using the Guest Mode ..29 Selecting the USER ID ..30 Using the USER ID.

2 30 Using the Single Mode ..31 Using the TruReadTMMode ..33 Special Conditions ..35 Using the Memory Function ..36 Averaging Function ..36To Display the Measurement Values ..37 Morning and Evening Averages ..39 Morning Averages ..39 Evening Averages ..39To Display Morning and Evening Averages ..40 Display Combinations ..41To Delete All Values Stored in the Memory ..42 Care and MaintenanceCare and Maintenance ..43 Error Indicators and Troubleshooting Tips ..45 FCC Statement ..47 Limited Warranties ..48 Specifications ..49 TABLE OF CONTENTS34 Thank you for purchasing the Omron BP785 IntelliSense AutomaticBlood pressure monitor with in for future PURCHASED: _____SERIAL NUMBER: _____Your new digital blood pressure monitor uses the oscillometric methodof blood pressure measurement. This means the monitor detects yourblood s movement through your brachial artery and converts themovements into a digital reading.

3 The monitor stores measurementresults for two people and features Morning and Evening for three consecutive measurements with timedintervals for an average BP785 comes with the following components: monitor ComFitTMCuff AC Adapter Storage Case INSTRUCTION MANUAL printed in English and Spanish Quick Start GuideThe BP785 IntelliSense Automatic blood pressure monitor is intendedfor home THESE INSTRUCTIONSB efore Using the monitor Staple your purchase receipt here Register your product on-line assure the correct use of the product basic safety measures shouldalways be followed including the warnings and cautions listed in thisinstruction MANUAL . WARNINGI ndicates a potentially hazardous situationwhich, if not avoided, could result in death orserious injury. SAFETY SYMBOLS USED IN THIS INSTRUCTION MANUALCAUTIONI ndicates a potentially hazardous situationwhich, if not avoided, may result in minor ormoderate injury to the user or patient ordamage to the equipment or other property.

4 OPERATING THE DEVICEC ontact your physician for specific information about your bloodpressure. Self-diagnosis and treatment using measured results may be dangerous. Follow the instructions of your physician or licensedhealthcare NOT adjust medication based on measurement resultsfrom this blood pressure monitor . Take medication asprescribed by your physician. Only a physician is qualified todiagnose and treat High blood monitor is not intended to be a diagnostic battery fluid should get in your eyes, immediately rinse withplenty of clean water. Contact a physician all of the information in the INSTRUCTION MANUAL and any otherliterature in the box before operating the INFORMATIONOPERATING THE DEVICE (continued)This device is intended for use in measuring blood pressure andpulse rate in the adult population. Do not use this device on infantsor persons who cannot express their the Special Conditions section (page 34) of the instructionmanual if your systolic pressure is known to be more than 220mmHg.

5 Inflating to a higher pressure than necessary may result inbruising where the cuff is the device only as intended. Do not use the device for anyother of the device, components and optional accessoriesaccording to applicable local regulations. Unlawful disposal maycause environmental not use a cellular phone near the device. It may result in anoperational only Omron authorized parts and accessories. Parts andaccessories not approved for use with the device may damage only alkaline batteries with this device. Do not use other types of batteries. This may damage the INFORMATION6 RISK OF ELECTRICAL SHOCKDo not plug or unplug the power cord into the electrical outlet withwet not overload power outlets. Plug the device into the appropriatevoltage AND MAINTENANCEDo not subject the monitor to strong shocks, such as dropping theunit on the not submerge the device or any of the components in the device and the components in a clean, safe or modification not approved by Omron Healthcare willvoid the user warranty.

6 Do not disassemble or attempt to repair theunit or INFORMATION78 BEFORE TAKING A MEASUREMENTTo ensure a reliable reading follow these recommendations:1. Avoid eating, drinking alcohol, smoking, exercising, and bathing for30 minutes prior to taking a measurement. Rest for at least 15minutes prior to taking the Stress raises blood pressure . Avoid taking measurements duringstressful Measurements should be taken in a quiet Remove tight-fitting clothing from your Sit on a chair with your feet flat on the floor. Rest your arm on a table so that the cuff is at the same level as your Remain still and do not talk during the Keep a record of your blood pressure and pulse readings for yourphysician. A single measurement may not provide an accurate indication of your true blood pressure . You need to take and recordseveral readings over a period of time. Try to measure your bloodpressure at about the same time each day for YOUR UNITMain Unit:Air JackBattery CompartmentStart/Stop ButtonUSER IDSelectionSwitchMorning/Evening Average() ButtonMemory () ButtonDisplayAC Adapter JackOperating InstructionsUp/Down (/) ButtonsCalibrationCheck SystemSET ButtonKNOW YOUR UNIT10 Components.

7 Arm CuffAir TubeAir Plug (Connects to Air Jack)AC AdapterStorage CaseHousingCordQuick Start GuideInstruction MANUAL 11 UNIT DISPLAYD iastolic blood PressureSystolic blood PressureMovement SymbolPulse Display / Memory NumberDate/Time DisplayLow Battery IndicatorDeflation SymbolMorning Average SymbolHeartbeat SymbolIrregular Heartbeat SymbolEvening Average SymbolAverage Value SymbolMemory SymbolUSER ID Symbol (A or B)Morning Hypertension SymbolWeek DisplayTruReadTMSymbolBlood pressure Level IndicatorCuff Wrap Guide12 IRREGULAR HEARTBEAT SYMBOL ()When the monitor detects an irregular rhythm two or more times duringthe measurement, the Irregular Heartbeat Symbol () will appear on thedisplay with the measurement irregular heartbeat rhythm is defined asa rhythm that varies by less than 25% fromthe average rhythm or 25% more than theaverage rhythm detected while the monitoris measuring the systolic and diastolic the irregular heartbeat symbol ()displays with your measurement results, werecommend you consult your the directions of your ERROR SYMBOL ()The Movement Error Symbol is displayed if you move your body duringthe measurement.

8 Please remove the arm cuff, and wait 2-3 another measurement, remain still during ID SYMBOL(/)The USER ID Symbol indicates USER A or USER B as selected by the user to take a measurement or when using the memory function. The USER ID Symbol is not displayed when using the Guest Mode totake a HeartbeatIrregular HeartbeatPulseBlood pressurePulseBlood pressureShortLongDISPLAY SYMBOLSThe American Heart Association1recommends the following guidelinefor upper limit of normal for home blood pressure readings:AHA Home Guideline for Upper Limit of Normal BPSystolic blood pressure 135 mmHgDiastolic blood pressure 85 mmHgThis is a general guideline because blood pressure depends onage and morbidity. The AHA recommends a lower home bloodpressure goal for certain patients, including diabetic patients,pregnant women, and patients with renal failure1. The monitor is not intended to be a diagnostic device. MORNING HYPERTENSION SYMBOL ()The Morning Hypertension Symbol is displayed if the morning averagereading for a week is above 135 for the Systolic blood pressure valueand/or 85 for the Diastolic blood pressure value when viewing theMorning Averages and the Evening Averages in the Healthcare recommends you contact your physician if theMORNING HYPERTENSION SYMBOL and/or the HEARTBEATSYMBOL appear on the display with your measurement SYMBOLS131 American Heart Association Scientific Statement 2004 HEARTBEAT SYMBOL ()TAKING A MEASUREMENTThe Heartbeat Symbol flashes on the display during themeasurement.

9 The Heartbeat Symbol flashes at every heartbeat. AVERAGE VALUE SYMBOL ()The Average Value Symbol is displayed when you press the memorybutton. The most recent average reading appears on the display AVERAGE SYMBOL ()The Morning Average symbol is displayed when viewing MorningAverages using the Memory AVERAGE SYMBOL ()The Evening Average symbol is displayed when viewing EveningAverages using the Memory Function. CUFF WRAP GUIDE SYMBOL(/)When the cuff is applied correctly, () is displayed while taking ameasurement or using the memory function. If the cuff is not appliedcorrectly, () is SYMBOLS14 IMPORTANT SAFETY INSTRUCTIONSSAVE THESE INSTRUCTIONSNOTES: Use only the authorized Omron AC Adapter that came withthis monitor . We recommend you install the batteries even if the ACAdapter is used. If no batteries are installed, you may need toreset the date and time if the AC Adapter is measurement results will not be only Omron authorized parts and accessories.

10 Parts andaccessories not approved for use with the device may damage THE AC ADAPTER15- DANGER -TO REDUCE THE RISK OFFIRE OR ELECTRIC SHOCK,CAREFULLY FOLLOW THESE connection to a power supply not in the , use anattachment plug adapter of the proper configuration for the power unit (AC Adapter) is intended to be correctly orientedin a vertical or floor mount CONNECT THE AC ADAPTER Insert the AC Adapter Plug intothe AC Adapter Jack on the backside of the monitor as illustrated. Plug the AC Adapter into a 120 VAC outlet (60 cycles).TO DISCONNECT THE AC ADAPTER Hold the Housing to remove the AC Adapter from the electricaloutlet. Remove the AC Adapter plug from the not plug or unplug the power cord into the electrical outlet withwet not overload power outlets. Plug the device into the appropriatevoltage THE AC ADAPTER16 HousingCord1. Remove the battery cover with pulling thehook up while pushing it in the directionof the Install 4 AA size batteries so the +(positive) and - (negative) polarities matchthe polarities of the battery compartmentas Replace the battery INSTALLATION17 Battery CoverBATTERY REPLACEMENTWhen the Low Battery Indicator appears on the display screen turn themonitor off and remove all the batteries.