Insulation Fastening System - Ramset

Insulation Fastening SystemThe Thermal Break Fastener that Installs in Seconds 2-3/8" Holding Diameter The fastener assembly is clearly branded Ramset along with the length of the fastener assemblyRamset-I-F Insulation Fastening System and up to 4X faster than stick-pin fasteners: No need to pre-measure fastener location or prepare substrate No need to wait for fastener plate adhesive to dry No need for fastener pins base plate No need to push washers on pins and trim pin length No need to tape over washersSafer than gun-powder-driven Fastening : Delivers less recoil to the installer No spent powder casings on the jobsite Does not require installer licensingSafer and faster than screw and washer fasteners: Delivers less torque to the installer's wrist and elbow Does not require assembly Drives faster than a screw tapsSubstrateInsulationFastenersMax Embedment DepthMineral WoolExtruded PolystyreneExpanded PolystyreneFiberglassPolyisocyanurateBeh ind cla

Insulation Fastening System The Thermal Break Fastener that Installs in Seconds ... Mineral Wool Extruded Polystyrene Expanded Polystyrene Fiberglass Polyisocyanurate ... High Density Polyethylene (HDPE) • Pin Diameter: 0.125 • 2-3/8" Holding Diameter

Tags:

  High, Polystyrene, Insulation, Density, Extruded, High density, Extruded polystyrene

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Insulation Fastening System - Ramset

1 Insulation Fastening SystemThe Thermal Break Fastener that Installs in Seconds 2-3/8" Holding Diameter The fastener assembly is clearly branded Ramset along with the length of the fastener assemblyRamset-I-F Insulation Fastening System and up to 4X faster than stick-pin fasteners: No need to pre-measure fastener location or prepare substrate No need to wait for fastener plate adhesive to dry No need for fastener pins base plate No need to push washers on pins and trim pin length No need to tape over washersSafer than gun-powder-driven Fastening : Delivers less recoil to the installer No spent powder casings on the jobsite Does not require installer licensingSafer and faster than screw and washer fasteners: Delivers less torque to the installer's wrist and elbow Does not require assembly Drives faster than a screw tapsSubstrateInsulationFastenersMax Embedment DepthMineral WoolExtruded PolystyreneExpanded PolystyreneFiberglassPolyisocyanurateBeh ind cladding over steel stud wallsBehind cladding over concrete block wallsBehind cladding over wood stud wallsInterior walls on concrete blockFoundations & basementsAbove acoustical ceilingsRamset-I-F will fasten into.

2 CONCRETE OR BLOCK1"1-1/2"2"2-1/2"3"3-1/2"4"5"6"Integ rated Cap For improved thermal efficiency and estheticsFlanges to ensure the Insulation remains in place, the Insulation panel does not slide on fastener during the installation processSpecialty Shaped Shaft Reduces friction and force required to insert fastener into insulationPoint designed to pierce difficult insulationmaterialEngineered curved design limits Insulation compression which enables full thermal performanceC Series pin provides exceptional performance in the hardest Series pin is equipped with a 2" spiral steel stud pin which fastens Insulation through exterior gypsum sheathing to exterior steel or wood studsPARTNUMBERDESCRIPTIONINSULATION THICKNESSBOX QTYIFC-100v21" Ramset -I-F w/Concrete Pin1"500 IFC-112v21-1/2" Ramset -I-F

3 W/Concrete Pin1-1/2"500 IFC-200v22" Ramset -I-F w/Concrete Pin2"500 IFC-212v22-1/2" Ramset -I-F w/Concrete Pin2-1/2"500 IFC-300v23" Ramset -I-F w/Concrete Pin3"500 IFC-312v23-1/2" Ramset -I-F w/Concrete Pin3-1/2"500 IFC-400v24" Ramset -I-F w/Concrete Pin4"500 IFC-500v25" Ramset -I-F w/Concrete Pin5"500 IFC-600v26" Ramset -I-F w/Concrete Pin6"400T3IF-6v2T3 Ramset -I-F Tool (6" Capacity)-1T3 FUELFuel Cells-1 FASTENERS FOR CONCRETE AND CMUPARTNUMBERDESCRIPTIONINSULATION THICKNESSBOX QTYIFS-1001" Ramset -I-F w/Steel Pin1"500 IFS-1121-1/2" Ramset -I-F w/Steel Pin1-1/2"500 IFS-2002" Ramset -I-F w/Steel Pin2"500 IFS-2122-1/2" Ramset -I-F w/Steel Pin2-1/2"500 IFS-3003" Ramset -I-F w/Steel Pin3"500 IFS-3123-1/2" Ramset -I-F w/Steel Pin3-1/2"500 IFS-4004" Ramset -I-F w/Steel Pin4"500 IFS-5005" Ramset -I-F w/Steel Pin5"500 IFS-6006" Ramset -I-F w/Steel Pin6"400T3IF-6T3 Ramset -I-F Tool (6" Capacity)-1T3fuelFuel Cells-1 FASTENERS FOR STEEL OR WOOD STUDSS election Charts.

4 STEEL OR WOOD1"1-1/2"2"2-1/2"3"3-1/2"4"5"6"Insula tion Thickness1 in2 in3 in4 in5 in6 inReferenceU Factor (W/m2 C) (%) PinU Factor (W/m2 C) (%) Factor (W/m2 C) (%) 700 high Grove Blvd. Glendale Heights, IL 60139 phone: 800-848-5611 : ICC-ESR-1955 ASTM E331 (Water Penetration) ASTM (Air Leakage)ASTM 84 (Surface Burning Characteristics) Pin Material: Heat treated carbon steel Pin Finish: Mechanical Zinc Plated Washer Material: high density Polyethylene (HDPE) Pin Diameter: 2-3/8" Holding Diameter The fastener assembly is clearly branded Ramset along with the length of the fastener assemblyFastener Specifications: 2017 Illinois Tool Works, Inc.

5 (INCH) (INCH)INSTALLED IN STONE AGGREGATE CONCRETEMINIMUM CONCRETE COMPRESSIVE STRENGTH (PSI)2000 PSI4000 - 414109 - 61178 - 42680 - 5743/4107 - 541156 - 855104 - 593195 - 977 HOLLOW CONCRETE BLOCKPART NUMBER PSI LT WT CONCRETEHOLLOW CONCRETE MASONRY UNITS (CMU) - ANY - 418108 - 54020 - 24334 - 2643/4108 - 540173 - 864----------STEEL STUDSPART NUMBER SERIESSHANK DIAMETER (INCH)INSTALLED IN COLD FORMED STEEL FRAMING (lbf)22 Gage20 Gage18 Gage16 Gage14 gage12gageIFS (Knurled) - 12033 - 20046 - 28060 - 36062 - 37175 - 448 WOODPART NUMBER SERIESSHANK DIAMETER (INCH)INSTALLED IN 15/32" (1/2 NOMINAL) 4 PLY PLYWOOD SHEATHING (lbf)IFS (Knurled) tool repair, please visit or call : CSI Division07-Thermal and moisture protection Insulation shall bemechanically fastened to the building substrate or component with Ramset -I-F Thermal-Break Insulation fasteners from ITW Ramset , Glendale Heights, this specification to the