Example: bachelor of science

Integrated Power Console (IPC™) - kebomed.dk

Service Manual Console and AttachmentsRx Only Integrated Power Console (IPC ) Models EC300 and 18980012 Released documents are available for viewing/printing @ are trademarks and are registered marks of Medtronic, Chuck is a registered mark of Jacobs Chuck Manufacturing Company The information contained in this document was accurate at time of publication. Medtronic reserves the right to make changes in the product de-scribed in this manual without notice and without incorporating those changes in any products already sold. NoticeThis manual is provided primarily for information purposes. Although there are certain troubleshooting actions that may be attempted by the customers as specifically listed in this manual, the majority of repairs must be undertaken by Medtronic Xomed or its authorized representative it otherwise being unsafe to maintain or repair this NumberDo not dispose of this product in the unsorted munici-pal waste stream.

3 Symbols N Serial Number Do not dispose of this product in the unsorted munici-pal waste stream. Dispose of this product according to local regulations. See http ...

Tags:

  Number

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Integrated Power Console (IPC™) - kebomed.dk

1 Service Manual Console and AttachmentsRx Only Integrated Power Console (IPC ) Models EC300 and 18980012 Released documents are available for viewing/printing @ are trademarks and are registered marks of Medtronic, Chuck is a registered mark of Jacobs Chuck Manufacturing Company The information contained in this document was accurate at time of publication. Medtronic reserves the right to make changes in the product de-scribed in this manual without notice and without incorporating those changes in any products already sold. NoticeThis manual is provided primarily for information purposes. Although there are certain troubleshooting actions that may be attempted by the customers as specifically listed in this manual, the majority of repairs must be undertaken by Medtronic Xomed or its authorized representative it otherwise being unsafe to maintain or repair this NumberDo not dispose of this product in the unsorted munici-pal waste stream.

2 Dispose of this product according to local regulations. See for instructions on proper disposal of this not use if package is open or damagedPackage Contents1 Pump Head 12 Pump Head 2 Use by DateDo not ReuseLOTLot NumberFuse ACCA ccessoryREFREFC atalog NumberAC powerOutputIs approximately equal toSTERILE RSterilized by radiation. Do not use if package is open or damagedSTERILENon sterileSTERILE EOSterilized by ethylene oxide. Do not use if package is open or damagedEC REPA uthorized representative in the european community0123 0086 This device complies with medical device directive 93/42/EECRx OnlyCaution: federal law ( ) Restricts this device to sale by or on the order of a physician! USAUSA OnlyQuantity ManufacturerDate of ManufactureROHS - Environmental friendly use period - China (SJ/T11364-2006.)

3 Table of ContentsSymbols ..4 General ..4 Definitions ..4 Warnings and Precautions ..4 Warnings ..4 Precaution ..5 System Description ..5 Sales and Customer Customers ..5 Medtronic Xomed, Inc.. Help Line ..5 Medtronic Powered Surgical Solutions .. Help Line ..5 International Service ..5 Components ..5 Integrated Power Console ..5 Console Front ..5 Connector Panel ..6 Connector Panel Cable Connection ..6 Connector Panel Cable Disconnection (multi pin) ..6 Cable Disconnection (single pin) ..6 Console Rear ..6 Console Pump Specifications ..7 Irrigation/Coolant Pumps ..7 Pump Cartridge Set-up ..7 Visao Pump Cartridge ..8 Visao Coolant Pump Set-Up ..8 Standard Pump Set-up ..8 Accessories/attachments ..8 Multifunction Foot Control Unit (FCU).

4 8 Intelliflow Irrigation Remote Control ..8 Endo-Scrub 2 ..8 Endo-Scrub 2 Assembly ..9 Suction Irrigator Adapter Kit ..9 Handpieces Microdebriders and SC1 ..9 Straightshot M4, Microdebriders, and Midas Rex SC1 9 Technical Specifications ..10 Straightshot Magnum II and Straightshot III Microdebriders ..10 Technical Specifications ..10 Handpieces Drills ..10 Visao High-Speed Otologic Drill (Water-Cooled) ..10 Technical Specifications ..10 Skeeter Ultra-Lite Oto-Tool System Set-Up and Use 10 Technical Specifications ..10 Midas Rex Legend EHS Motor ..10 Technical Specifications ..11 Midas Rex Legend EHS Stylus Motor ..11 Technical Specifications ..11 System Overview ..11 Set-Up ..12 Inspect: ..12 Configure System: ..12 Functional Test.

5 12 Main Screen ..12 Power Down ..13 Cleaning ..13 Calibration ..13 Settings Test-Electrical Safety Specifications ..13 Troubleshooting ..15 Error Code ..16 Changing the Fuse ..174>120 VACNot greater than 120VA CON<120sOFF>180sApplied part duty cycle <XX C XX C XX C>X CRecommended storage temperature and to ANSI/AAMI ES 60601-1, IEC/EN 60601-1. Certified to CSA handpieceEUR USA JPN AUS EMC compliance markProtective EarthEquipotentialConsult instructions for useAttention see instructions for useIPX1 Protected against vertical water dropsIPX7 Protected against the effects of temporary immersion in waterMType bF applied partManual Start/StopRF transmitter (interference may occur)Precaution: Pinch hazard. Keep fingers clear of rollersBURSTIM b UR connectorNIMNIM Console connectorEHSE lectrical high speed handpiece connectorFoot pedal connectorFrWorld Wide Standard for medical tubing irrigant adjustmentLeft foot control unit buttonRight foot control unit buttonTop foot control unit buttonLockedUnlockedOn/Off (main Power )

6 Use withInstrument CaseInstrument caseLubricant/DiffuserLubricant/Diffuser Dissecting ToolDissecting ToolAttachmentAttachmentControl UnitControl UnitRefurbishedRefurbishedAccessoryAcces soryRegulatorRegulatorBone Millbone MillMotorMotorBrushbrushAdapterAdapterTO OLTool controlTUbETube controlMult i-Use Disp osable Atta chmentMulti-Use Disposable AttachmentNOTEIT IS IMPORTANT THAT THE OPERATOR BE FAMILIAR WITH THIS MANUAL AND THE USER S GUIDE WITH THEIR WARNINGS, PRECAUTIONS, PROCEDURES AND SAFETY Alphabetic list (A. b. C. etc.) contain introductory information where Numeric list (1. 2. 3. etc.) are How To Explaining the essential meaning of a word or acronym as used in this manual. Also explains changes in words or phrases variations from one product generation to the Foot Control UnitIPC - Integrated Power - IntravenousNIM - Nerve Integrity Monitor - One or all of the following units: NIM-Response , NIM-Pulse , NIM-Response , NIM-Pulse , NIM-Neuro , NIM-Response , NIM-Pulse , NIM-Neuro The act or process or an instance of namingWarnings and PrecautionsWarningsW1 The IPC shall only be serviced by trained technicians at an authorized Medtronic service facilityW2 The IPC contains live circuitry that can cause injury or death if the enclosure is IPC contains live circuitry that can cause injury or death to operators or patients if assembled incorrectly.

7 This document and the documents referenced herein are not sufficient to guarantee correct assembly and operation of the device. Product specific training and product specific test equipment is required to ensure the correct operation and assembly of the IPC .W4 This system requires insulated connectors for the StraightShot M4 Microdebrider, Straightshot Magnum II Microdebrider, Straightshot III Microdebrider, Midas Rex SC1, Visao , or Skeeter handpieces and the Multi Function Foot Control Power Outlet with protective cover is for use with the HydroDebrider , or bone Mill consoles Priming is a feature designed to purge air out of the tubing set(s) during setup. The first time a Prime or Flush button is pressed it will turn on pump 1 and/or 2 long enough to purge air out of the tubing set(s).

8 Turning Power Off and On resets the Prime feature. Once pressed all Prime buttons will change to Flush DescriptionThe IPC System is a powered microdebrider, drill and saw system that will remove soft tissue, hard tissue, bone, and biomaterials during surgical procedures. The system consists of a Power control Console , footswitch, connection cables, and assorted handpieces to drive various burs, blades, drills, rasps, cannulae, and saws. It includes Integrated irrigation pumps for irrigation of blades, burs and for motor coolant. The Nerve Integrity Monitor (NIM ) is a separate device that stimulates and monitors the nerve. This system has connections that allow the NIM to be connected with the Visao handpiece and Stimulating bur Guard enabling the NIM to stimulate and monitor the nerve at the surgical system can be used to clear the end of a rigid rod endoscope in order to maintain good visualization of endoscopic procedures without having to remove the scope from the surgical site.

9 This device is intended for use by physicians trained in the procedures and Customer CareMedtronic is committed to provide the highest standard of workmanship in manufacturing its products. Your system requires minimal maintenance and and/or modification to the system, or any accessory/attachment by anyone other than qualified service personnel may significantly compromise the systems performance and void the equipment warranty. For best performance, it is recommended that all service be performed by Medtronic Xomed service recommends preventative maintenance and screen calibration scheduled at yearly intervals. Comprehensive testing and calibration should be performed by returning the entire system to Medtronic Customer Service. CustomersShould your Console or related equipment malfunction, Medtronic provides, at no charge, loaner equipment shipped to your facility by UPS or Federal Express for use while your equipment is being serviced by Medtronic.

10 Please adhere to the following guidelines:When a loaner Console is ordered, please reuse the shipping material 1. and carton when you return your Console to Medtronic. Insure the a loaner is not ordered, please package the Console as safely as 2. possible and return goods authorization number is required on repairs. A copy 3. of your purchase order is required. Make certain the purchase order includes the following:Shipping and billing information Purchase order number Contact person Phone number Description of malfunction Your Medtronic account number Please indicate preferred method of return shipment. Otherwise the 4. unit will be shipped back via UPS the malfunctioning unit is not covered by warranty, 5. Medtronic will contact your facility promptly with a repair cost estimate if requested.


Related search queries