Example: dental hygienist

Internal Measurement - tesatool.com

Internal MeasurementInternal MeasurementC-1C-2 Internal MeasurementInternal Measuring and RequirementsInternal measuring of bores is more demanding than external Measurement ofworkpieces. Not only the tight tolerances given for the measuring job must berespected, but also the measuring components that have a direct influence onthe uncertainty of Measurement must be designed in such a way that they canenter into the bore to be of 3-Line contactTESA IMICRO, TRIOMATIC, TRI-O-BOR and ETALON INTALOMETER are self-centring and self-aligninginternal measuring instruments that make bore Measurement reliableindependently of the sensitivity of the 3 measuringbolts spaced 120 apart provide opti-mum contact of the 3 measuring bolts allowsthe instrument to align itself parallel to thecontact contactdoes not allow theinstrument to alignitself in relation tothe bore contact measuring instruments arenot self-centring.

C-2 Internal Measurement Internal Measuring and Requirements Internal measuring of bores is more demanding than external measurement of workpieces.

Tags:

  Internal, Measurement, Internal measurement

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Internal Measurement - tesatool.com

1 Internal MeasurementInternal MeasurementC-1C-2 Internal MeasurementInternal Measuring and RequirementsInternal measuring of bores is more demanding than external Measurement ofworkpieces. Not only the tight tolerances given for the measuring job must berespected, but also the measuring components that have a direct influence onthe uncertainty of Measurement must be designed in such a way that they canenter into the bore to be of 3-Line contactTESA IMICRO, TRIOMATIC, TRI-O-BOR and ETALON INTALOMETER are self-centring and self-aligninginternal measuring instruments that make bore Measurement reliableindependently of the sensitivity of the 3 measuringbolts spaced 120 apart provide opti-mum contact of the 3 measuring bolts allowsthe instrument to align itself parallel to thecontact contactdoes not allow theinstrument to alignitself in relation tothe bore contact measuring instruments arenot self-centring.

2 To make bore measure-ment easier, auxiliary means will addition-ally be single measuring instrument can replacehundreds of plug gaugesUnlike plug gauges that check onlyone toleranced size, a single instru-ment can measure many on the model that is beingused, through bores and blind boresas well as short centring shoulderscan be measured, form errorsForm errors are established by meas-urements made at several points onthe instruments with 3-line contact determine run-out errors in a triangular instruments with 2-pointcontact measure medium-size diam-eters only. They do not allow the userto differentiate diameters measuredat various C-3 TESA IMICRO capa system with Digital DisplayNew TESA capacitive measuring system (patented) associated with the unique cone of the TESA IMICRO Internal micrometers.

3 DIN 863 T4(style C1)0,001 mm inmm / inConversionLCD, 7 mmdigit heightFloatingzeroDisplay lock Measuringfaces for application ranges3,5 to 12 mm: hardenedsteel (770 HV)11 to 100 mm : TIN hard-coating, 0,05 4000 to 6000 HV100 to 300 mm : carbidetipped (1300 HV)Opto-coupledRS 232 interface, bidirectional3 V lithiumbattery1 to 2 a( 2000 h/a)Automaticshut down after10 min. Display settingis retained as long aspower supply C to 40 C 10 C to 60 C80 %, with nocondensation Protection ofthe meas. ele-ment IP 54 (IEC 60529)or IP 40 with use of digi-tal outputPlasticcaseIdentificationnumberIn- house calibra-tion certificateDeclaration of conformitymmin m ,5 , 4, , ,5 5, , ,5 6, , ,52, ,52, ,52, , , , Lithium battery - 3 V, 190 mAh, type CR 2032 For ordering information on cables etc.

4 , see section cases on page MicrometersABCC-4 TESA IMICRO Partial Sets with capa system and Digital DisplayNew TESA capacitive measuring system (patented) associated with the unique cone of the TESA IMICRO Internal sets including:Meas. element Measuring headsSetting ,5 6, ,5 4, , ,5 5, ,5 6, 50 200 DIN 863 T4(style C1)0,001 mm inmm / inconversionLCD, 7 mmdigit heightFloatingzeroDisplay lock Measuringfaces for application ranges3,5 to 12 mm: steelhardened to 770 HV11 to 100 mm: TIN hard-coating, hardnessto 0,05 2300 to 300 mm : carbidetipped (1300 HV)Opto-coupledRS 232 interface, V lithiumbattery1 to 2 a( 2000 h/a)Automaticshut down after10 min.

5 Display settingis retained as long aspower supply C to 40 C 10 C to 60 C80 %, with nocondensation Protection ofthe meas. ele-ment IP 54 (IEC 60529)or IP 40 with use of digi-tal outputPlasticcaseIdentificationnumberIn- house calibra-tion certificiateDeclaration of conformityInternal MicrometersC-5 TESA IMICRO Full Sets with capa system and Digital DisplayNew TESA capacitive measuring system (patented) associated with the unique cone of the TESA IMICRO Internal sets including:Single instrumentSetting ,5 6, ,5 4, , ,5 5, ,5 6, 200 DIN 863 T4(style C1)0,001 mm inmm / inconversionLCD, 7 mmdigit heightFloatingzeroDisplay lock Measuringfaces for application ranges6 to 12 mm : hardenedsteel (770 HV)11 to 100 mm.

6 TIN hard-coating, 0,05 4000 to 6000 HV100 to 300 mm : carbidetipped (1300 HV)Opto-coupledRS 232 interface, V lithiumbattery1 to 2 a( 2000 h/a)Automaticshut down after 10 min. Display setting is retained aslong as power supplyremains C to 40 C 10 C to 60 C80 %, with nocondensation Protection ofthe meas. ele-ment IP 54 (IEC 60529)or IP 40 with use of digital outputPlasticcaseIdentificationnumberIn- house calibra-tion certificateDeclaration of conformityInternal MicrometersC-6mmmm m ,5 40,0014421, 4,50,0014421, ,5 5,50,0014421, ,5 6,50,0014421, 80,001442,52, 100,001442,52, 120,001442,52, 140,005443, 170,005443, 200,005443, 250, 300, 350, 400, 500, 600, 70 0, 800, 900, 1000, 1250, 1500, 1750, 2000, 2250, 2500, 2750, 3000,0188261881 TESA IMICRO with Analogue Indication, MetricSelf-centring and self-aligning Internal micrometers.

7 The high-precision thread, machined into the measuring cone, combined with the measuring bolts specially arranged to provide 3 line contact make the Imicros the onlymicrometers in the world that respect the ABBE to measure depths, reliably. DIN 863 T4(style C1)NF E 11-099 Models from3,5 to 12 mmwith vernier readingMeasuring faceson models from3,5 to 12 mm: steelhardened to 770 HV 11 to 100 mm:titanium nitride hard-coating (TIN), hardness0,05 2300 to 300 mm : tungstencarbide tipped,hardness 1300 from 3,5 to 200 mm:shipping box200 to 300 mm:wooden case with:1 extension 150 mm( )Identification numberInspection report with a declaration of conformityACBI nternal MicrometersC-7mmmmmmmmFull sets including:Single instrumentsSetting ,5 6, ,5 4, , ,5 5, ,5 6, 200 DIN 863 T4(style C1)NF E 11-099 Measuring faceson models from3,5 to 12 mm :hardened steel11 to 100 mm.

8 Titanium nitride hard-coating (TIN), hardness0,05 2300 to 200 mm :tungsten carbide tippedAdditionaltechnical data :see on previous page C-6 Setting rings on page C-24 Plastic caseor suitcaseIdentification numberInspectionreport with adeclaration of conformityTESA IMICRO with AnalogueIndicationin Full Metric SetsInternal MicrometersC-8 DIN 863 T4(style C1)NF E 11-099 Models to inwith vernierMeasuring faceson models to in :hardened to in :hardenedsteel4 to 12 in :tungsten carbide tippedAdditional-technical data :see page rings on page C-24 Single instruments :shipping box. Full sets :plastic case or suitcaseIdentificationnumberInspection report with adeclaration of sets including:Single instr.

9 Setting IMICRO with AnalogueIndication Inch ModelsInternal MicrometersC-9 Centring Devices for TESA IMICRO Optional Accessories for TESA IMICRO and TESA IMICRO capa system DIN 863 T4(Form C1)Extensions for Deep Hole for single instruments ,5 6, Cases for Single Instruments, Full Setsand Partial SetsmminCases forCases for fullfull setsor partial ,5 6, 100 200 200 Internal MicrometersC-10 Internal Micrometers DIN 863 C1 formodels 6 to 10 mm or C2 for all other models0,001 mm inmm / inconversionLCD, height ofdigits : 7 mmFloatingzeroDisplaylockMeasuringinsert s for application ranges6 to 10 mm : steelhardened to 30 550 HV10 to 300.

10 Tungsten car-bide tipped 70 HRCOpto-coupled RS 232 interface, V lithium battery1 to 2 a( 2000 h/a)Automatic shut down after 10 min. Display setting is retained as longas power supply C to 40 C 10 C to 60 C80 %, with nocondensation For the meas- uring element :IP54 (IEC 60529) or IP 40 with use of the digital output 100 mm in aplastic case > 100 mm in a wood caseIdentificationnumberInspectionreport with adeclaration of conformityTESA ALESOMETER capa system with Digital DisplayNew patented TESA s capacitive measuring systemInternal micrometers with 3-line contact. All TESA ALESOMETER are speciallysuited for through and blind bores as well as short centring shoulders, exceptfor the models covering the application ranges from 6 to 10 m mAmm* , , 12, , ,5 , 17, , ,5 , , , , , , , , , , Lithium battery - 3 V, 190 mAh, type CR 2032* Not applicable to the models from 10 mm since the measuring inserts are close to the instrument s front ordering information on setting rings, see both pages C-13 and C-24.