Example: bachelor of science

International Plumbing Code - iccsafe.org

1 Chapter 1 Administration No changes addressed Chapter 2 Defi nitions Chapter 3 General Regulations Chapter 4 Fixture, Faucets, and Fixtures Chapter 5 Water Heaters Chapter 6 Water Supply Distribution Chapter 7 Sanitary Drainage Chapter 8 Indirect/Special Waste Chapter 9 Vents Chapter 10 Traps, Interceptors, and Separator Chapter 11 Storm Drainage Chapter 12 Special Piping and Storage No changes addressed Chapter 13 Gray Water Recycling Systems Chapter 14 Referenced Standards No changes addressedChapter 1 of the International Plumbing code (IPC) clarifi es how the code will be enforced by code offi cials. Defi nitions of Plumbing code terminology are found in Chapter 2. General regula-tions in Chapter 3 identify requirements not listed in other code chapters, such as testing and inspections. Fixtures and water heaters are addressed in Chapters 4 and 5, respectively.

The new terminology now makes a clear distinction between the two types of grease interceptors, hydromechanical and gravity. The revision to the defi nition along with the changes made in Section 1003.3.4 place the IPC in better alignment ... 3. ® PART 1 International Plumbing Code ...

Tags:

  International, Code, Plumbing, International plumbing code

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of International Plumbing Code - iccsafe.org

1 1 Chapter 1 Administration No changes addressed Chapter 2 Defi nitions Chapter 3 General Regulations Chapter 4 Fixture, Faucets, and Fixtures Chapter 5 Water Heaters Chapter 6 Water Supply Distribution Chapter 7 Sanitary Drainage Chapter 8 Indirect/Special Waste Chapter 9 Vents Chapter 10 Traps, Interceptors, and Separator Chapter 11 Storm Drainage Chapter 12 Special Piping and Storage No changes addressed Chapter 13 Gray Water Recycling Systems Chapter 14 Referenced Standards No changes addressedChapter 1 of the International Plumbing code (IPC) clarifi es how the code will be enforced by code offi cials. Defi nitions of Plumbing code terminology are found in Chapter 2. General regula-tions in Chapter 3 identify requirements not listed in other code chapters, such as testing and inspections. Fixtures and water heaters are addressed in Chapters 4 and 5, respectively.

2 Chapters 6 and 7 regulate water and drainage piping systems, in that order. Indirect/special waste is covered in Chapter 8. Chapter 9 details acceptable venting methodologies with in-depth pip-ing arrangements. The provisions for traps with vari-ous receptors are found in Chapter 10. Storm drainage, with its piping collection system, is covered in Chapter 11. Installation, design, storage, handling, and use of nonfl ammable medical gas systems are addressed in Chapter 12. Gray-water recycling systems are now addressed in Chapter 13. Standards are identifi ed with clear guidelines in Chapter 14. Appendices A through F cover nonmandatory provisions for permit fees, rain-fall rates, vacuum drainage, degree design tempera-tures, a water sizing method, and structural protection methodology. International Plumbing CodeChapters 1 through 16/29/11 12:54 PM6/29/11 12.

3 54 PM2202 Plumbing Fixture Defi nition202 Plumbing Appliance Defi nition202 Grease Interceptor Defi , Identifi cation and Third-Party Certifi Water Distribution of Annular Spaces at PenetrationsTABLE Number of Required Plumbing Toilet Facilities in Group M or Assisted-Use Toilet Facilities Serving as Separate of Toilet Rooms and Food Preparation of Toilet Room Fountain Water Closet Compartment and Wall Waste Outlets and Overfl ows410 Minimum Required Number of Drinking Pan Liner Closet Personal Hygiene Heater Storage Tank Relief Heater Pans605 Polyethylene of Raised-Temperature (PE-RT) Plastic TubingTABLE (PE) Water Service PipeTABLE Water Service of Water Distribution Pipes in or Tempered Water Supply to Water Piping cation of Nonpotable , Branch ConnectionsTABLE Fixture Units for Bathroom Pump and Ejector Discharge Pipe and Pump Connection to the Drainage Protection from Sewage Backfl ow2 SGNSC 26/29/11 12:54 PM6/29/11 12:54 Drains in Multi-Level Parking and Grease Interceptor Grease Interceptors1105 Roof Drain Strainers1107 Siphonic Roof Drainage SystemsCHAPTER 13 Gray-Water Recycling Discharge of Food Preparation of Indirect Waste Locations for Waste , Admittance Valves for Chemical Waste Vent of Vent Waste and Vent System Sizing917 Single-Stack Vent 36/29/11 12:54 PM6/29/11 12:54 PM4 PART 1 International Plumbing CodeCHANGE TYPE: Modifi cationCHANGE SUMMARY.

4 The defi nition of Plumbing fi xture has been modifi ed to include fi xtures such as waterless code : Plumbing Fixture. A receptacle or device that is either permanently or temporarily connected to the a water distribution supply system or of the premises and demands a supply of water therefrom; discharges wastewater, liquid-borne waste materials or sewage either directly or indirectly to a the drainage system of the premises; or requires both. Such receptacles or devices require a water supply of water; connection and a or discharge liquid waste or liquid-borne solid waste; or require a supply of water and discharge waste to a the drainage system of the SIGNIFICANCE: The previous defi nition of Plumbing fi xture was outdated and incomplete. The defi nition now includes receptacles and devices that do not necessarily require connection to a water supply.

5 Waterless urinals and fl oor drains, now addressed in the revised defi nition, were not defi ned as Plumbing fi xtures in the Fixture Defi nitionInternational code Council Waterless urinalSGNSC 46/29/11 12:54 PM6/29/11 12:54 PMSignifi cant Changes to the IPC 2012 Edition 202 Plumbing Appliance Defi nition 5202 Plumbing Appliance Defi nitionCHANGE TYPE: Clarifi cationCHANGE SUMMARY: The defi nition of Plumbing appliance has been changed to clarify the difference between appliances and fi code : Plumbing Appliance. Any one of a special class of Plumbing fi xtures Water-connected or drain-connected devices intended to perform a special function. Included are fi xtures having the These devices have their operation or control dependent on one or more energized components, such as motors, controls, or heating elements or pressure or temperature sensing elements.

6 Such fi xtures devices are manually adjusted or controlled by the owner or operator, or are operated automatically through one or more of the following actions; a time cycle, a temperature range, a pressure range, a measured volume or SIGNIFICANCE: The modifi ed defi nition of Plumbing appliance provides a better distinction between appliances and fi xtures. The revised text updates and simplifi es the defi nition, now recognizing these two classes as different. Examples of Plumbing appliances include dishwashers, clothes washers, garbage disposals, water softeners, water purifi ers, and water garbage disposalInternational code Council 56/29/11 12:54 PM6/29/11 12:54 PM6 PART 1 International Plumbing Code202 Grease Interceptor Defi nitionCHANGE TYPE: Modifi cationCHANGE SUMMARY: The defi nition of grease interceptor has been modifi ed for consistency with current industry terms for the two general types of grease interceptors being used in Plumbing code : Grease Interceptor.

7 A Plumbing appurtenance that is installed in a sanitary drainage system to intercept oily and greasy wastes from a wastewater discharge. Such device has the ability to intercept free-fl oating fats and Plumbing appurtenances that are installed in the sanitary drainage system to intercept free-fl oating fats, oils and grease from wastewater discharge. Continuous separation is accomplished by air entrainment, buoyancy and interior baffl Plumbing appurtenances of not less than 500 gallons (1893 L) capacity that are installed in the sanitary drainage system to intercept free-fl oating fats, oils and grease from wastewater discharge. Separation is accomplished by gravity during a retention time of not less than 30 installation of a typical hydromechanical grease interceptor (Courtesy of Thermaco, Inc. 2010 )Solid manhole coverStepsGrout(typical)OutletCast irontee withcleanoutplugConcrete baffleCast ironlong 1/4 bend6" thickconcrete pad7"24"12"8"10" CO36" diameterprecastmanholebarrel sectionGrade or pavingAs requiredWaterlevelInletPrecastconcretegr easeinterceptorTypical concrete grease interceptorInternational code Council SGNSC 66/29/11 12:54 PM6/29/11 12:54 PMSignifi cant Changes to the IPC 2012 Edition 202 Grease Interceptor Defi nition 7 CHANGE SIGNIFICANCE: The provisions of Section addressing grease interceptors and automatic grease removal devices were never intended to apply to gravity grease interceptors.

8 The new terminology now makes a clear distinction between the two types of grease interceptors, hydromechanical and gravity. The revision to the defi nition along with the changes made in Section place the IPC in better alignment with product standards and industry terminology. Both types of grease interceptors require diligent effort by restaurant facility managers and staff to ensure that they are regularly maintained and properly serviced. For a grease collection device to work correctly, it must be properly designed, installed, maintained, and serviced 76/29/11 12:54 PM6/29/11 12:54 PM8 PART 1 International Plumbing , Identifi cation and Third-Party Certifi cationCHANGE TYPE: Clarifi cationCHANGE SUMMARY: The identifi cation requirements for Plumbing products and materials have been clarifi code : Identifi cation. Each length of pipe and each pipe fi tting, trap, fi xture, material, and device utilized in a Plumbing system shall bear the identifi cation of the manufacturer and any markings required by the applicable referenced Third-Party Testing and Certifi cation.

9 All Plumbing products and materials shall comply be listed by a third-party certifi cation agency as complying with the referenced standards, specifi cations and perfor-mance criteria of this code . and shall be identifi ed in accordance with Section When required by Table , Plumbing products and ma-terials shall either be tested by an approved third party testing agency or certifi ed by an approved third party certifi cation agency. Products and materials shall be identifi ed in accordance with Section Products and Materials Requiring Third-Party Testing and Third-Party Certifi cationProduct or MaterialThird-Party Certifi edThird-Party TestedPotable water supply system components and potable water fi xture fi ttingsRequired Sanitary drainage and vent system componentsPlastic pipe, fi ttings and pipe-related componentsAll OthersWaste fi xture fi ttingsPlastic pipe, fi ttings and pipe-related componentsAll OthersStorm drainage system componentsPlastic pipe, fi ttings and pipe-related componentsAll OthersPlumbing fi xtures RequiredPlumbing appliancesRequired Backfl ow prevention devicesRequired Water distribution system safety devicesRequired Special waste system components RequiredSubsoil drainage system components RequiredSGNSC 86/29/11 12:54 PM6/29/11 12.

10 54 PMSignifi cant Changes to the IPC 2012 Edition , Material Identifi cation 9 PEX tubing label with complete identifi cation and conformance information (Courtesy of Uponor Corporation)CHANGE SIGNIFICANCE: The modifi cation to the identifi cation provisions of Section clarifi es the intent of the code that products and materials shall bear the identifi cation of the manufacturer, as well as the identifi cation requirements that are referenced by the applicable standard. As a result of the modifi cations made to Section , all Plumbing products and materials must now be listed by a third-party certifi cation agency. Table was deleted as a result of the modifi cations made to Section 96/29/11 12:54 PM6/29/11 12:54 PM10 PART 1 International Plumbing Water Distribution SystemsCHANGE TYPE: Modifi cationCHANGE SUMMARY: In parallel water distribution systems, the hot and cold water piping may now be grouped in the same pipe code : Parallel Water Distribution Systems.


Related search queries