Intruder alarm system Engineering Information

Intruder alarm systemEngineering InformationThe above Intruder systems are designed tocomply with the installation requirements ofBS 4737 1986 manual provides Information on Installationdesign, panel fixing, wiring , power up andprogramming of the Intruder 395 Optima G3 panelwith built-in keypad8EP 396 Optima compact G3 panelwith built-in keypadAttackTamperDay12345678 PowerAccentaG3mini01235678 ChimeOmitReset49 SetProgPAAttackTamperDay12345678 PowerAccentaG3miniPower01235678 ChimeOmitReset49 SetProgZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 ZONE 8 TamperAttackDayPowerPAAccenta01235678 ChimeOmitReset49 SetProgZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 ZONE 8 TamperAttackDayPowerPAAccenta8SP 401 Accenta G3 panelwith remote LED keypad8SP 400 Accenta mini G3 panelwith remote LED keypadFeatures 8 zones, all programmable for Security,Fire, 24H Fire, PTS or keyswitchapplications PA input Tamper input Outputs for Bell and Strobe 4 Access level Codes, User 1, User 2,Engineer and Duress, all programmable 3 fully selectable part set programs Chime on any zone 8 event memory Programmable timers including bell cut off Walk Test facilities Quick set feature Remote keypad with on board PA andilluminated keys standard for Accentapanels and Optional for Optima panels Option for connection of Lig

Intruder alarm system Engineering Information The above intruder systems are designed to comply with the installation requirements of BS 4737 1986/87.

Tags:

  Information, System, Engineering, Lamar, Intruder, Intruder alarm system engineering information

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Intruder alarm system Engineering Information

1 Intruder alarm systemEngineering InformationThe above Intruder systems are designed tocomply with the installation requirements ofBS 4737 1986 manual provides Information on Installationdesign, panel fixing, wiring , power up andprogramming of the Intruder 395 Optima G3 panelwith built-in keypad8EP 396 Optima compact G3 panelwith built-in keypadAttackTamperDay12345678 PowerAccentaG3mini01235678 ChimeOmitReset49 SetProgPAAttackTamperDay12345678 PowerAccentaG3miniPower01235678 ChimeOmitReset49 SetProgZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 ZONE 8 TamperAttackDayPowerPAAccenta01235678 ChimeOmitReset49 SetProgZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 ZONE 8 TamperAttackDayPowerPAAccenta8SP 401 Accenta G3 panelwith remote LED keypad8SP 400 Accenta mini G3 panelwith remote LED keypadFeatures 8 zones, all programmable for Security,Fire, 24H Fire, PTS or keyswitchapplications PA input Tamper input Outputs for Bell and Strobe 4 Access level Codes, User 1, User 2,Engineer and Duress, all programmable 3 fully selectable part set programs Chime on any zone 8 event memory Programmable timers including bell cut off Walk Test facilities Quick set feature Remote keypad with on board PA andilluminated keys standard for Accentapanels and Optional for Optima panels Option for connection of Lightingcontrollers Options to connect up to four remotekeypads / Lighting controllers NVM for protection of engineer programme 6 digital outputs for a wire-in digitalcommunicator, Red Care STU or dialler(Not applicable for Optima compact G3panel)

2 Service warning indicator, programmablebetween 100 and 800 set and unset events Battery capacity of up to in Accenta/Optima G3 mini enclosure7Ah in Accenta/Optima G3 enclosure Optima G3 and Optima G3 mini are suppliedwith built in keypad24PI175 issue 1_6/01 Engineering informationAccenta/Optima G3 Intruder systemFeaturesContentsFeatures---------- ---------2 Installation Design--------------3 Fixing--------------------3 Wiring the system --------------5 Tamper network---------------5 Connect Remote Keypads / Lighting controllers 5 Security zones----------------5 Push to set zone---------------6 Remote keyswitch zone-----------6 Fire zone------------------6PA circuit------------------6 Extension speaker--------------7 Bell Output (External sounder)--------713V Supply output--------------8 Set ---------------------8 Remote signalling Input and Outputs-----8 Filtering of Intruder alarms-----------9 Factory set condition-------------10 First Power up----------------11 Mains Connection--------------11 Testing the system --------------12 Engineer program mode-----------12To exit---------------------12 system indications--------------12To enter Engineer program mode-------12To Exit Engineer program mode-------12To reset panel to Factory set conditions----12 Access Codes----------------13 Programs------------------14 Zone Function per Program----------14 Exit Modes program-------------14 Programs 1.

3 2 and 3--------------15 alarm and Walk tests------------16 Communicator tests-------------17 Flag A Options---------------17 Flag B options---------------18 Viewing the event log------------18 Zone Type------------------19 Zone Attributes---------------20 Bell and Service Timers-----------21Re-arm and Anticode reset code-------22 Lighting controller--------------23 Faults--------------------24 Specification-----------------25 Servicing organisation Details--------27 Parts--------------------27 Quick Reference---------------288zRKP4 PARTSETMEM8 OUTPUT6 REMOTESET509 Installation DesignThe purchase of this alarm system represents amajor step forward in the protection of theproperty and its occupants. It is important to planthe installation before proceeding and the followthe procedures and advice contained in the position of each part ofthe alarm system and the be sitedwith particular regard to thedegree of coverage requiredand the function of each of the of the system wiring isconnected directly to Accenta panel may beconcealed inside a cupboard orloft space, but it must beinstalled within the protectedpremises and in a position which is convenientfor a mains supply.

4 The Optima panel may beinstalled near an entry/exit keypads(RKPs)should be mounted in positionswhich allows ease of operationfor the system users, typicallywithin the entry/exit route closeto the final door and the master internalsoundspeakersare recommended,these will provide high volumealarm tones and low volumeentry/exit tones. Speakers shouldbe positioned to provide good sound distributionthroughout the building and so that the exit toneis audible outside the main entry / exit will enable the system operator to checkthat the system is setting note that thetotalcurrentoutput of thiscontrol system (in alarmcondition) is 1 Amp whensupported by a fully chargedbattery. Calculate the totalcurrent consumption of every part of the systemincluding the panel, remote keypads,bell/sounders, strobes and detectors to ensurethat this rating is not on which areayou live, you may berequired, by law to notifytheLocal AuthorityandPolice of the new securityalarm installation.

5 Thelocal authority requirements may differ fromarea to area, therefore, it is advisable to contactlocal environmental officer to obtain full detailsof your area :When positioning the controlpanel ensure that it is located in a dryplace away from damp Accenta mini G3 enclosure is illustratedhere, however the procedures for the otherpanels are the front cover(s) from the transformer wires fromthe transformer markedACterminalson the board. Carefully remove thePCB by gently pushing down theholding clips on the bottom edge of thePCB and withdraw it from the issue 1_6/013 Accenta/Optima G3 Intruder systemEngineering informationInstallation DesignITOTALLA PowerAccentaG3mini01235678 ChimeOmitReset49 SetProgZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 ZONE 8 TamperAttackDayPowerPAAccentaNote:When replacing the PCB align iton the round support pillars to thebottom and allow it to click down pastthe clips at the top of the case.

6 Refit thetransformer wires into the the panel to the wall with suitablefixings. Ensure the wall surface is flat toprevent base distortion. There arecable entry holes provided in the rearof the base and around the outsideedges through the thinned out plasticsections which may be cut away hole provided adjacent to themains transformer is a dedicated mainscable entry are four fuses mounted on the circuitboard, all are 20mm quick - to protect the +ve line of 12V batteryF2 1A - to protect the RKP 13V supplyF3 1A - to protect the Speaker 13V supplyF5 1A - to protect the Bell and Strobe supplyAs supplied, wire links are fitted across the PAand Tamper terminals to represent a issue 1_6/01 Engineering informationAccenta/Optima G3 Intruder systemFixingJ2PA+TAMP-+13V 0V-STROBEJ6+-ACTAMP+TASCBDBBELL+ / SPEAKERBATTERYBATTJ4F1F3F5J50 VTAMP+13 VCOMMSSOUNDVR1 VOLUME214365871 ARKP FUSEF2 ABORTJ3+13VL/FAIL0 VFIRE PAINTSETCONFF actory fitted links01235678 CHIMEOMITRESET49 SETPROGC ommunicator is not fittedto Optima compact G3 panelKeypad and LEDs (except Power LED) are notfitted to Accenta G3 and Accenta mini G3 panelsD1D2D3D4D5D6D7D8D9D10D22D18 Mounting holesMounting holesCable entryholes Wiring the systemCaution:Alwayspower-downthe panelwhen wiring external circuits, to preventdamage to the panel wire and test each circuits.

7 : Zone, Tamper circuit and PA circuits Finish by wiring any additional extensionspeaker sounders, external bell/sounder,strobe and the 13V networkThe Tamper circuit is used to protect all cablesand detectors in the system from unauthorisedaccess including the panel and RKP zone and PA tampers should be series wiredand connected to the TAMP bell /sounder tamper. The TAMP terminals at thebottom left of the PCB are for the RKP alarms that occur in the Day modeoperate internal sounders only. Tamper alarms inSet cause a full alarm condition. Tamper isindicated on the control panel and RKPs by Remote Keypads /Lighting controllersNote:Where an Accenta G3 or Accentamini G3 panel is being installed ensurethere is at least one remote keypad wiredto the panel before first power combination of up to four remote keypads andlighting controller can be connected to the zonesNote:The G3 range of panels arenotsupplied with wire linksfor unusedzones.

8 All unused zones must beprogrammed out by setting them todisabledusing theZone Typefunctionsee page is recommended that no more than 10magnetic contacts are connected to the issue 1_6/015 Accenta/Optima G3 Intruder systemEngineering informationWiring the systemJ50 VTAMP+13 VCOMMSSOUND1 ARKP FUSEF2 PanelBoardSOUNDTAMPCOMMS13V0 VKeypadBoardCOMMS12 VSOUNDLD RMaximum of up to 4 Remote Keypad /OPTI-CAM Lighting Controllercombination allowedBoardSOUNDTAMPCOMMS13V0 VKeypadBoardGNDOPTI-CAM LightingController(See also the instructions suppliedwith the OPTI CAM lighting controller)If only one Remote keypadis being used then connect TAMP back to thepanelJ221436587 PanelAlarm+-PA+-TAMP+13V 0 VPIRU nused zones mustbe programmed blockis not suppliedTampPush to set zoneAny zone can be wired and configured as a Pushto Set input. This can be a standard door bellpush located outside the premises After startingthe exit timer the building is vacated.

9 As theswitch is then momentaraily closed, a chimetone is produced and the system referred to as Terminate Set thisfacility is mandatory for communicatingsystems installed to NACOSS guidelinesRemote keyswitch zoneAny zone can be wired and programmed as akeyswitch input and used with a remotekeyswitch or lock switch. For security reasons itis recommended that a tamper proof switch isused and that the switch wiring is not accessiblefrom outside the keyswitch may be used to Set (opencontacts) or Unset (closed contacts)independently of RKPs. However in thissituation the keyswitch may have to catch up with the system . For example if the system is Setvia an RKP and Unset with the keyswitch, itwould have to be momentarily turned to its Setposition then returned to its Unset keyswitch will always Set program 1. It willalso Unset the system or switch off an alarmactivation.

10 To Reset after an alarm and return toDay mode, the Reset key on the RKP will haveto be zoneAny zone may be programmed as a fire will automatically exclude the availabilityof the zone from programs and normal are two types of fire zone,Standardand24 hourtype. TheStandard firezone detectsfires only when the system is Set, where as the24 hour firezone detects fires all the time andwill operate whether the system is Set or fire will cause a distinctive internal soundertone. The external sounders will pulse on and offat 2 second intervals and all RKP indicators willflash the affected circuitAny quantity of normally closed type personalattack button may be wired in series and thenconnected to the PA in Day and Set, the PA circuit willcause a full alarm condition when activated. PAis indicated on the control panel or RKP issue 1_6/01 Engineering informationAccenta/Optima G3 Intruder systemPush to set zoneJ221436587 PanelPA+-TAMP+13V 0 VBoardKeyswitchNote: A keyswitch can beconnected to any zone must be programmedfor keyswitch +-TAMP+13V 0 VBoardFire detectorNote: Fire detector withrelay base for outputto Intruder +-TAMP+13V 0 VBoardPress to Set SwitchNote: The push to set switchcan be connected to any zone must be programmedfor PTS buttons may be fitted near the front door, orin a speakerExtension speaker may be connected to theloudspeaker terminals to produce high volumealarm tones and low volume entry / exit to two 16 ohm extension speakers may alsobe wired across the speaker terminals.