- 3 - INVERTER WALL MOUNTED TYPEROOM AIR-CONDITIONER( split system , air to air heat pump type )SRK50 ZHX-S, SRK60 ZHX-SManual No. 08 . SRK-T . 079 CONTENTS1 GENERAL INFORMATION .. Specific features .. How to read the model name .. 12 SELECTION DATA .. Specifications .. Range of usage & limitations .. Exterior dimensions .. Piping system .. Selection chart .. 63 ELECTRICAL DATA .. Electrical wiring .. 74 OUTLINE OF OPERATION CONTROL BY MICROCOMPUTER .. Operation control function by remote control switch .. Unit ON/OFF button .. Auto restart function .. Custom cord switching procedure .. Flap and louver control .. 3D auto operation.

-3 -INVERTER WALL MOUNTED TYPE ROOM AIR-CONDITIONER ( Split system, air to air heat pump type ) SRK50ZHX-S, SRK60ZHX-S Manual No. ’08 . SRK-T . 079

Tags:

  System, Types, Walls, Mounted, Room, Conditioners, Split, Inverter, Inverter wall mounted type room air, Inverter wall mounted type room air conditioner, Split system

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of INVERTER WALL MOUNTED TYPE ROOM AIR …

1 - 3 - INVERTER WALL MOUNTED TYPEROOM AIR-CONDITIONER( split system , air to air heat pump type )SRK50 ZHX-S, SRK60 ZHX-SManual No. 08 . SRK-T . 079 CONTENTS1 GENERAL INFORMATION .. Specific features .. How to read the model name .. 12 SELECTION DATA .. Specifications .. Range of usage & limitations .. Exterior dimensions .. Piping system .. Selection chart .. 63 ELECTRICAL DATA .. Electrical wiring .. 74 OUTLINE OF OPERATION CONTROL BY MICROCOMPUTER .. Operation control function by remote control switch .. Unit ON/OFF button .. Auto restart function .. Custom cord switching procedure .. Flap and louver control .. 3D auto operation.

2 Timer operation .. Installation location setting .. Outline of heating operation .. Outline of cooling operation .. Outline of automatic operation .. Protective control function .. 155 APPLICATION DATA .. Selection of location for installation .. Installation of indoor unit .. Installation of outdoor unit .. Connection of refrigerant pipings .. Test run .. Precautions for wireless remote control installation andoperation .. 296 MAINTENANCE DATA .. Troubleshooting procedures for electrical equipment .. Servicing .. 487 REFRIGERANT PIPING INSTALLATION / SERVICING MANUALFOR AIR conditioners USING R410A .. Outline .. Refrigerant piping installation .. Installation, removal and servicing.

3 Refrigerant recovery .. 61- 1 -Over heat of compressorError of signal transmissionOutdoor fan motor error1 GENERAL Specific featuresThe MITSUBISHI HEAVY INDUSTRIES, LTD room air-conditioner: SRK series are of split and wall MOUNTED type and the unitconsists of indoor unit and outdoor unit with refrigerant precharged in factory. The indoor unit is composed of room air cooling orheating equipment with operation control switch and the outdoor unit is composed of condensing unit with compressor.(1) INVERTER (Frequency converter) for multi-steps power control Heating/CoolingThe rotational speed of a compressor is changed in step in relation to varying load, interlocked with the indoor and outdoor unitfans controlled to change frequency, thus controlling the capacity.

4 Allowing quick heating/cooling operation during start-up period. Constant room temperature by fine-tuned control after the unithas stabilized.(2) Fuzzy control Fuzzy control calculates the amount of variation in the difference between the return air temperature and the setting temperaturein compliance with the fuzzy rules in order to control the air capacity and the INVERTER frequency.(3) Remote control flap & louverThe flap & louver can be automatically controlled by operating wireless remote control. Flap swing: The flaps swing up and down successively. Louver swing: The louvers swing left and right successively. 3D auto operation : Fan speed and air flow direction are automatically controlled, allowing the entire room to be efficientlyconditioned.

5 Memory flap: Once the flap & louver position is set, the unit memorizes the position and continues to operate at thesame position from the next time.(4) Self diagnosis function We are constantly trying to do better service to our customers by installing such judges that show abnormality of operation heat exchanger liquidpipe sensor errorDischarge pipe sensor errorOutdoor temperature sensor error2 time flash4 time flashRUN lightkeeps flashing1 time flashTrouble of outdoor unitOver currentCurrent cut2 time flash3 time flashRUN lightON1 time flash5 time flashTIMER lightR410A modelsSeries typeProduct capacityWall MOUNTED typeSplit type room How to read the model nameExample :SR K 50 Z HX - SRoom temperature sensor errorHeat exchanger sensor 3 errorHeat exchanger sensor 1 error2 time flash3 time flashTIMER lightON1 time flashRUN lightRotor lock6 time flash7 time flash2 time flashRUN light2 time flash4 time flashPower transistor error6 time flashIndoor fan motor errorCooling high pressure protectionkeep flashingActive filter voltage errorONRUN light5 time flashTIMER light- 2 -Model SRK50 ZHX-S (Indoor unit)SRC50 ZHX-S (Outdoor unit)ItemModelSRK50 ZHX-SSRC50 ZHX-SCooling capacity(1)W5000 (700~6200)Heating capacity(1)W6000 (700~8800)Power source1 Phase, 220-240V, 50 HzCooling inputkW ( ~ )Running current (Cooling) ( ~ )Running current (Heating) : Heating.

6 Cooling Sound levelHi 45, Me 38, Lo 2648 Noise level Power leveldB6062 Heating Sound levelHi 45, Me 38, Lo 3248 Power level6262 Exterior dimensionsHeight Width Depthmm309 890 220640 800 290 ColorFine snowStucco whiteNet weightkg1543 Refrigerant equipmentCompressor type & Q ty 5CS130 XGB04 [Scroll type] 1 MotorkW method Line startingHeat exchangerNew Louver fins & inner grooved tubingNew M fins & inner grooved tubingRefrigerant controlCapillary tubes + Electronic expansion valveRefrigerant(3)kgR410A (Pre-Charged up to the piping length of 15m)Refrigerant (RB68A or Freol Alpha 68M)Deice controlMicrocomputer controlAir handling equipmentFan type & Q tyTangential fan 1 Propeller fan 1 MotorW2734(Cooling)Hi Me 11 Lo flow(Heating)CMMHi Me Lo filter, Q tyPolypropylene net (washable) 2 Shock & vibration absorber Cushion rubber (for compressor)Electric heater Operation controlOperation switchWireless-Remote control room temperature controlMicrocomputer thermostat Pilot lampRUN (Green), TIMER (Yellow), HI POWER (Green), 3D AUTO (Green), ECONO (Blue)Safety (in)Liquid line: (1/4 )Gas line: (1/2 )Connecting methodFlare connectingAttached length of pipingLiquid line: mGas line.

7 M InsulationNecessary (Both sides)Drain hoseConnectablePower source cord Size Core mm2 4 cores (Including earth cable)Connection wiringConnecting methodTerminal block (Screw fixing type)Accessories (included)Mounting kit, Clean filter (Allergen clear filter x1, Photocatalytic washable deodorizing filter x1)Optional partsInterface kitNotes (1) The data are measured at the following air temperatureOutdoor air temperatureStandardsOperationDBWBDBWBC ooling27 C19 C35 C24 CISO-T1, JIS C9612 Heating20 C 7 C6 CISO-T1, JIS C9612(2) The operation data are applied to the 220/230/240V districts respectively.(3) The refrigerant quantity to be charged includes the refrigerant in 15 m connecting piping. (Purging is not required even for the short piping.)

8 If the piping length is longer, when it is 15 to 30m, add 20 g refrigerant per meter.(4)If the interface kit (SC-BIKN-E) (sold separately) is connected to the terminals on the indoor unit s circuit board, a wired remote control (sold separately)can be connected, a Super Link (with SC-ADN-E sold separately) can be connected, and the unit can be turned on and off from a CNT data(1)RefrigerantpipingCompressor overheat protection, Heating overload protection (High pressure control), Overcurrent protection,Frost protection, Serial signal error protection, Indoor fan motor error protection, Cooling overload protectionThe piping length is (220/230/240V)2 SELECTION Specifications- 3 -Model SRK60 ZHX-S (Indoor unit)SRC60 ZHX-S (Outdoor unit)ItemModelSRK60 ZHX-SSRC60 ZHX-SCooling capacity(1)W6000 (800~6800)

9 Heating capacity(1)W6800 (800~9700)Power source1 Phase, 220-240V, 50 HzCooling inputkW ( ~ )Running current (Cooling) ( ~ )Running current (Heating) : Heating: Cooling Sound levelHi 47, Me 38, Lo 2651 Noise level Power leveldB6265 Heating Sound levelHi 45, Me 39, Lo 3351 Power level6265 Exterior dimensionsHeight Width Depthmm309 890 220640 800 290 ColorFine snowStucco whiteNet weightkg1543 Refrigerant equipmentCompressor type & Q ty 5CS130 XGB04 [Scroll type] 1 MotorkW method Line startingHeat exchangerNew Louver fins & inner grooved tubingNew M fins & inner grooved tubingRefrigerant controlCapillary tubes + Electronic expansion valveRefrigerant(3)kgR410A (Pre-Charged up to the piping length of 15m)Refrigerant (RB68A or Freol Alpha 68M)

10 Deice controlMicrocomputer controlAir handling equipmentFan type & Q tyTangential fan 1 Propeller fan 1 MotorW2734(Cooling)Hi Me Lo flow(Heating)CMMHi Me Lo filter, Q tyPolypropylene net (washable) 2 Shock & vibration absorber Cushion rubber (for compressor)Electric heater Operation controlOperation switchWireless-Remote control room temperature controlMicrocomputer thermostat Pilot lampRUN (Green), TIMER (Yellow), HI POWER (Green), 3D AUTO (Green), ECONO (Blue)Safety (in)Liquid line: (1/4 )Gas line: (1/2 )Connecting methodFlare connectingAttached length of pipingLiquid line: mGas line : m InsulationNecessary (Both sides)Drain hoseConnectablePower source cord Size Core mm2 4 cores (Including earth cable)Connection wiringConnecting methodTerminal block (Screw fixing type)Accessories (included)Mounting kit, Clean filter (Allergen clear filter x1, Photocatalytic washable deodorizing filter x1)Optional partsInterface kitNotes (1) The data are measured at the following air temperatureOutdoor air temperatureStandardsOperationDBWBDBWBC ooling27 C19 C35 C24 CISO-T1, JIS C9612 Heating20 C 7 C6 CISO-T1, JIS C9612(2) The operation data are applied to the 220/230/240V districts respectively.