Example: air traffic controller

ISOTECH Calibrator - Venus - AcezOnline

Temperature ISOTECH Calibrator Venus Calibrator Features - Calibrate Whole Measurement Loop, using a heat source rather than an electrical simulator a test instrument and probe can be calibrated as a system. - Calibrate as a Dry or Liquid Bath, thermocouples, platinum resistance Pressure thermometers, thermistors, liquid in glass, thermostats, semiconductor types. - Covers key calibration points from below to above ambient, 0 C, 121 C (250 F), 135 C. - Simple To Use - Outstanding Value for Money! - S Model Includes Universal Input Temperature Indicator allowing for Humidity up to ve correction points to be programmed. - Windows Software and PC Interface as Standard. - Free Evaluation Report dataloggers Recorder &. SPECIFICATIONS OPTIONS. Temperature 55 C below ambient to +140 C 1. Metal Block Insert 951-02-15 Standard Insert Included Range (absolute minimum -55 C) 951-02-15A Blank Insert Insert without Absolute stability Dry Block Bath C pockets for local machining over 30 minutes Stirred Liquid Bath C 951-02-15C Special Insert Ice/Water Bath C Contact us with your Blackbody Source C requirements Surface Sensor Calibrator C Alternative Metal Block Inserts Air Flow ITS-90 Fixed Point Apparatus 951-06-07 Standard Insert type B.

Acez Instruments Pte Ltd | www.acez.com.sg Pressure Humidity Recorder & Dataloggers Air Flow Level & Flow Portable Instruments EX Proof / IS Calibrator

Tags:

  Calibrator, Dataloggers

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of ISOTECH Calibrator - Venus - AcezOnline

1 Temperature ISOTECH Calibrator Venus Calibrator Features - Calibrate Whole Measurement Loop, using a heat source rather than an electrical simulator a test instrument and probe can be calibrated as a system. - Calibrate as a Dry or Liquid Bath, thermocouples, platinum resistance Pressure thermometers, thermistors, liquid in glass, thermostats, semiconductor types. - Covers key calibration points from below to above ambient, 0 C, 121 C (250 F), 135 C. - Simple To Use - Outstanding Value for Money! - S Model Includes Universal Input Temperature Indicator allowing for Humidity up to ve correction points to be programmed. - Windows Software and PC Interface as Standard. - Free Evaluation Report dataloggers Recorder &. SPECIFICATIONS OPTIONS. Temperature 55 C below ambient to +140 C 1. Metal Block Insert 951-02-15 Standard Insert Included Range (absolute minimum -55 C) 951-02-15A Blank Insert Insert without Absolute stability Dry Block Bath C pockets for local machining over 30 minutes Stirred Liquid Bath C 951-02-15C Special Insert Ice/Water Bath C Contact us with your Blackbody Source C requirements Surface Sensor Calibrator C Alternative Metal Block Inserts Air Flow ITS-90 Fixed Point Apparatus 951-06-07 Standard Insert type B.

2 C 13mm, 10mm, 8mm, 5mm, Computer Interface Included with Software and diameter holes Cools from 140 C to 0 C in 15 minutes all 157mm deep. Heats from -30 C to 140 C in 15 minutes 951-06-08 Special Insert type C 8mm, Best Performance See Graph 6 x diameter holes, Level & Flow Calibration volume 35mm diameter by 160mm deep all 157 deep Standard Insert 6 pockets, , , , 2. Stirred Liquid Bath 951-06-01 Includes a container, , , , all 157mm deep 3. Water/Ice Bath magnetic stirrer and Uniformity C probe guide Display Resolution ( to ) Thermometer 951-06-03 Allows three thermometers ( to and to ) Support Kit to be suspended in the PC can display across bath, including liquid in whole range with the software included glass types Instruments Indicator units C, F, K Oil 520-05-01 Portable Power 100 to 120V (50 / 60 Hz) or -35 C to 140 C. 200 to 240V (50 / 60 Hz) 4. Blackbody Target 951-06-04 Use with Standard Probe 150 Watts (935-14-82). Overall dimensions Height 302mm 5.

3 Surface Sensor Kit 951-06-02 Includes an Insert and Width 176mm an angled PRT. Depth 262mm 6. Fixed Point Cells D8 Water Slim Cell Weight 17401 Slim Gallium Slim Cell EX Proof / IS. Includes as standard Standard insert, traceable certi cate, serial Standard Probe 935-14-82 Platinum Resistance communications, Cal Notepad software Thermometer UKAS Calibration UKAS Calibration available to Order MODEL DESCRIPTION Carrying Case 931-22-64 Sturdy case accommodates the unit with room for Venus Plus 2140 (Basic) Basic Multifuction Calibrator accessories Venus Plus 2140 (On site) On site Multifuction Calibrator Environment (Optional accessories refer to above). Acez Instruments Pte Ltd | 67.