Read this manual before use of productIWAKI Magnetic Drive PumpMDM Series (ANSI)Instruction ManualT383-4 '03/08 SingaporeIndonesiaMalaysiaTaiwanThailand Hong : (65)6316 2028 TEL : (62)21 690 6606 TEL : (60)3 7803 8807 TEL : (886)2 8227 6900 TEL : (66)2 322 2471 TEL : (852)2 607 1168 TEL : (86)750 380 9018 TEL : (86)20 8435 0603 TEL : (86)10 6442 7713 TEL : (86)21 6272 7502 TEL : (63)2 888 0245 TEL : (82)2 3474 0523 TEL : (1)508 429 1440 TEL : (61)2 9899 2411 GermanyItaly Denmark Sweden FinlandNorway AustriaHolland SpainBelgiumTEL : (49)2154 9254 0 TEL : (39)02 990 3931 TEL : (45)48 24 2345 TEL : (46)8 511 72900 TEL : (358)9 2742714 TEL : (47)66 81 16 60 TEL : (33)1 69 63 33 70 TEL : (44)1743 231363 TEL : (41)26 674 9300 TEL : (43)2236 33469 TEL : (31)297 241121 TEL : (34)943 630030 TEL : (32)1367 0200: IWAKI Si

Thank you for selecting IWAKI Magnetic Drive Pump MDM Series. This instruction manual, which is divided into five sections, namely "Safety", "Outline of Product",

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of IWAKI Magnetic Drive Pump

1 Read this manual before use of productIWAKI Magnetic Drive PumpMDM Series (ANSI)Instruction ManualT383-4 '03/08 SingaporeIndonesiaMalaysiaTaiwanThailand Hong : (65)6316 2028 TEL : (62)21 690 6606 TEL : (60)3 7803 8807 TEL : (886)2 8227 6900 TEL : (66)2 322 2471 TEL : (852)2 607 1168 TEL : (86)750 380 9018 TEL : (86)20 8435 0603 TEL : (86)10 6442 7713 TEL : (86)21 6272 7502 TEL : (63)2 888 0245 TEL : (82)2 3474 0523 TEL : (1)508 429 1440 TEL : (61)2 9899 2411 GermanyItaly Denmark Sweden FinlandNorway AustriaHolland SpainBelgiumTEL : (49)2154 9254 0 TEL : (39)02 990 3931 TEL : (45)48 24 2345 TEL : (46)8 511 72900 TEL : (358)9 2742714 TEL : (47)66 81 16 60 TEL : (33)1 69 63 33 70 TEL : (44)1743 231363 TEL : (41)26 674 9300 TEL : (43)2236 33469 TEL : (31)297 241121 TEL : (34)943 630030 TEL : (32)1367 0200: IWAKI Singapore Pte.

2 Ltd.: IWAKI Singapore (Indonesia Branch): IWAKIm Sdn. Bhd.: IWAKI Pumps Taiwan Co., Ltd.: IWAKI (Thailand) Co.,Ltd.: IWAKI Pumps Co., Ltd.: IWAKI Pumps (Guandong) Co., Ltd.: GFTZ IWAKI Engineering & Trading (Guangzhou): IWAKI Pumps Co., Ltd. (Beijing): IWAKI Pumps (Shanghai) Co., Ltd.: IWAKI Chemical Pumps Philippines, Inc.: IWAKI Korea Co.,Ltd.: IWAKI WALCHEM Corporation: IWAKI Pumps Australia Pty. : 6316 3221 FAX : 21 690 6612 FAX : 3 7803 4800 FAX : 2 8227 6818 FAX : 2 322 2477 FAX : 2 607 1000 FAX : 750 380 9078 FAX : 20 8435 9181 FAX : 10 6442 7712 FAX : 21 6272 6929 FAX : 2 843 3096 FAX : 2 3474 0221 FAX : 508 429 1386 FAX : 2 9899 2421( )Country codesIWAKI CO.

3 , Kanda-Sudacho 2-chome Chiyoda-ku Tokyo 101-8558 JapanTEL:(81)3 3254 2935 FAX:3 3252 8892( ): IWAKI EUROPE GmbH: IWAKI Italia : IWAKI Pumper A/S : IWAKI Sverige AB: IWAKI Suomi Oy: IWAKI Norge AS: IWAKI France : IWAKI PUMPS (UK) LTD.: IWAKI (Schweiz) AG: IWAKI (Austria) GmbH: IWAKI Holland : IWAKI Iberica Pumps, : IWAKI Belgium : 2154 1028 FAX : 02 990 42888 FAX : 48 24 2346 FAX : 8 511 72922 FAX : 9 2742715 FAX : 66 81 16 61 FAX : 1 64 49 92 73 FAX : 1743 366507 FAX : 26 674 9302 FAX : 2236 33469 FAX : 297 273902 FAX : 943 628799 FAX : 1367 2030 Thank you for selecting IWAKI Magnetic Drive Pump MDM Series.

4 This instructionmanual, which is divided into five sections, namely "Safety", "Outline of Product","Installation", "Operation" and "Maintenance", deals with the correct handling andoperation procedures for the pump. To make maximum use of the pump and toensure safe and long time operation of the pump, please read this manual thoroughlyand carefully prior to operating the OF Unpacking and Model Conditions to be Structure and names of Electrical Precautions on Operation (Starting)..1610.

5 Pump Trouble Maintenance & Disassembling & Repair parts Mass of the Safe and Correct Handling of the Pump Before use of the pump, read carefully this "Safety Section" to prevent accidents and toavoid the damage or loss of other assets. Observe and abide by the instructions described in this "Safety Section". These instruc-tions are very important for protecting pump users or other persons from hazard orfrom loss of assets. Meaning of symbolsFollowing two symbols describe the extent of hazards and loss which may brought if theinstructions are not observed or if the pump is wrongly two symbols describe the content to be SECTIONW arningNonobservance or misapplication of the contents ofthe "Warning" could lead to a death or heavy injury or misapplication of the contents of the"Caution" could lead to a injury of person or damage action or procedure is indicated.

6 Inside ornear this circle, a concrete activity to be prohibited or procedure which must be performed withoutfail is indicated. Inside this circle, a concrete activityto be performed is Magnet field dangerThe magnet Drive pumps contain very strong magnets. The strong magnet fieldcould adversely affect persons who are assisted by electronic devices such aspacemakers etc. Always turn off power supply prior to maintenance works etc. Pay special attentionso that no other operator turns on by mistake the power supply while someone isworking on the pump.

7 In a noisy or poor visibility environment, display a sign nearpower supply switch to notify other person that someone is "WORKING" on thepump. Power supply mistakenly turned on during maintenance works may lead topersonal injury. Each operator must pay special attention. Wear protectorsWhen piping is removed or pump is disassembled/assembled, wear protective gearsuch as safety goggles and protective gloves etc. Lifting pumpWhen pump is lifted, apply chain or belt to eye bolt and motor to keep the pump &motor horizontally.

8 No remodelingRemodeling of pump may result in serious personal injury or damage of the not attempt remodeling pump because it is very offWear protective gearNo Remodeling Dangerous liquidWhen the pump is used to transfer dangerous liquids mentioned as below, thepump must always be checked and watched so that the liquid can not be operation of pump leaking the liquid may result in personal injury, explosion orfire accident. Explosive or flammable liquids Corrosive or stimulus toxic liquids Liquids harmful to human healthSafety Section-3-CAUTION Attention to Magnetic forceThis pump employs strong magnets.

9 Special attention must be paid not to be injuredby attracting force of magnets. Follow the procedure "Disassembling andAssembling" when the maintenance works are done. Do not run pump dryDo not run pump dry (without liquid). If the pump run dry, heat is generated by rub-bing, which causes pump damage. If the pump is operated with suction side valveclosed, the pump runs dry. Countermeasures for static electricityWhen low electric conductivity liquid such as ultra-pure water and fluor inactive liq-uid ( Fluorinert are handled, the static electricity may be generated in thepump, which may cause static discharge and pump break down.)

10 Take countermea-sures to avoid and remove the static electricity. Qualified operatorThe pump must be handled or operated by the person who has enough knowledgeand well acquainted with the pump. For specified application onlyThe use of pump in any application other than those clearly specified may result inthe failure or damage of the not run dry Disposal of used pumpDisposal of used or damaged pump must be done in accordance with local laws andregulations. (Consult a licensed industrial waste products disposing company.) Ventilate the siteWhen handling the liquid which may generate toxic gas, safety measures such asventilation must be taken to prepare for the accidental liquid leakage.