IXT7 AInstallationManualEnglishMAEN016F,2013- 09 ForewordInstallationmanualforiXT7 AForewordAlloperator panels aredeveloped tosatisfy thedemands ofhuman-machinecommunication. Built-infunctions such as displaying and controllingtext,dynamic indication, time channels,alarm and recipe handling are works primarily in an object-orientedway, makingit easy tounderstand and use. Configuration is carriedout on a PCusingtheiXDeveloperconfigurationtool. The project can then be transferred and stored in the operatorpanel types ofautomationequipment such PLCs,servosordrives can beconnected to the operator panels. In thismanual,the term the controller refersto explains how to install the operatorpanel. Please referto theiX Developer reference manual for further no: MAEN016 FCopyright 2013-09 Beijer Electronics in thisdocumentissubjectto changewithoutnoticeandisprovidedasavaila bleatthetime ofprinting. BeijerElectronicsAB, including all its group companies, reservesthe rightto change anyinformation without updating this publication.

TechnicalData 3TechnicalData Parameter iXT7A Frontpanel,W×H×D 204×143×7mm Cutoutdimensions, W×H 187×126mm Mountingdepth 43mm(143mmincludingclearance)

Tags:

  Ixt7a

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of iXT7A - Beijer Electronics

1 IXT7 AInstallationManualEnglishMAEN016F,2013- 09 ForewordInstallationmanualforiXT7 AForewordAlloperator panels aredeveloped tosatisfy thedemands ofhuman-machinecommunication. Built-infunctions such as displaying and controllingtext,dynamic indication, time channels,alarm and recipe handling are works primarily in an object-orientedway, makingit easy tounderstand and use. Configuration is carriedout on a PCusingtheiXDeveloperconfigurationtool. The project can then be transferred and stored in the operatorpanel types ofautomationequipment such PLCs,servosordrives can beconnected to the operator panels. In thismanual,the term the controller refersto explains how to install the operatorpanel. Please referto theiX Developer reference manual for further no: MAEN016 FCopyright 2013-09 Beijer Electronics in thisdocumentissubjectto changewithoutnoticeandisprovidedasavaila bleatthetime ofprinting. BeijerElectronicsAB, including all its group companies, reservesthe rightto change anyinformation without updating this publication.

2 Beijer Electronics AB,including all its groupcompanies,assumesnoresponsibilityfo ranyerrorsthatmayappearinthisdocument. Readtheentireinstallationmanual priorto installing and usingthis equipment. Only qualified personnel mayinstall,operateor repairthis equipment. Beijer Electronics AB,including allits groupcompanies,are not responsible for modified,altered orrenovatedequipment. Becausethe equipment hasa wide rangeof applications, usersmust acquiretheappropriate knowledge to use theequipment properly in their specific applications. Persons responsiblefor the application and the equipment must themselves ensure that each application is in compliance withall relevant requirements, standards andlegislationinrespecttoconfigurationan dsafety. Onlypartsandaccessoriesmanufactured according to specificationsset by Beijer Electronics AB,including all its groupcompanies,maybe ELECTRONICSAB,INCLUDING ALL ITSGROUPCOMPANIES, SHALL NOTBE LIABLETO ANYONEFOR ANYDIRECT,INDIRECT,SPECIAL,INCIDENTAL OR CONSEQUENTIALDAMAGES RESULTING FROM THE INSTALLATION, USE ORREPAIR OF THIS EQUIPMENT,WHETHERARISINGIN TORT,CONTRACT,OR 'SSOLE REMEDY SHALLBETHE REPAIR,REPLACEMENT,OR REFUNDOFPURCHASEPRICE,ANDTHECHOICE OF THE APPLICABLEREMEDY SHALLBEAT THE SOLEDISCRETION OFBEIJERELECTRONICSAB,INCLUDINGALL , MAEN016 FContentsContents1 SafetyPrecautions.

3 General .. ULand cUL Installation .. DuringInstallation .. DuringUse .. Serviceand Maintenance .. Dismantlingand Appearance of Air in Touch Screen ..72 Installation .. SpaceRequirements .. InstallationProcess ..113 TechnicalData .. 124 ChemicalResistance .. MetalCasing .. Touch Screen and Overlay ..165 OperatorPanelDrawings .. Connectors .. CommunicationPorts .. iXT7 AOutline ..196 AdditionalInstallation Tips .. GroundingtheOperatorPanel .. Ethernet Connection in theOperator Panel .. To Achieve BetterEMC Protection .. AmbientTemperature .. Safety .. GalvanicIsolation .. Cable and Bus TerminationRS485 ..27 BeijerElectronics, MAEN016 FSafety Precautions1 SafetyPrecautionsBoth theinstaller and the owner and/oroperatorof theoperatorpanel must readand understand thisinstallation General Read the safety precautionscarefully. Check the delivery for transportationdamage.

4 Ifdamage is found, notifythesupplier assoon aspossible. Donot use the operator panelinan environment with high explosive hazards. The supplier is not responsible formodified, altered orreconstructedequipment. Use only parts and accessories manufactured according to specifications ofthesupplier. Read the installation and operatinginstructions carefully before installing,usingor repairingtheoperatorpanel. Neverallowfluids,metalfilingsorwiringdeb ristoenteranyopeningsintheoperator panel. This may cause fire orelectricalshock. Onlyqualified personnel may operate the operatorpanel. Storing the operator panelwhere the temperature islower/higherthanrecommended in this manualcan causetheLCDdisplay liquidtocongeal/becomeisotopic. The LCDdisplay liquidcontainsa powerful irritant. Incase of skincontact,wash immediately with plenty ofwater. In caseof eyecontact, holdtheeyeopen,flushwithplentyofwaterand getmedicalattention. associated with any particular installation,the supplier cannotassume responsibility for actual use based onthe figures.

5 The supplierneither guarantees thatthe operator panel is suitable foryourparticularapplication, nor assumesresponsibilityforyour product design,installation or operation. It is recommended to turn on and shut down theoperatorpanel at least oncebefore installinganycomponents/cards orbefore connecting the operatorpaneltoexternaldevices,likefor exampleserial ULandcULInstallationCaution:Thissectioni sonlyvalidforULlabelediXT7 Apanels. This equipment is suitable forusein Class 2non-hazardous locations only.[Combinations ofequipment in yoursystem aresubject to investigation bythe local authorityhavingjurisdiction at the time ofinstallation].BeijerElectronics, MAEN016F4 Safety Precautions All deviceshavetobesupplied bya Class :Donotdisconnectequipmentunlesspowerhasb eenremovedortheareaisknowntobenon-hazard ous ForCanada also AVERTISSEMENT AVANTDE DECONNECTERL EQUIPEMENT, COUPERLECOURANT OUS ASSURERQUEL EMPLACEMENTEST DESIGNENON :OnlyULandcULapprovedexpansionunitsareal lowedtobeconnectedtotheportdesignated EXPANSION.

6 :Donotreplaceexpansionunitunlesspowerhas beenswitchedoffortheareaisknowntobenon-h azardous. This product contains a battery;this must onlybechangedin an areaknowntobenon-hazardous. Replace the battery with aBR 2032 battery. Use of another type ofbatterymaypresent a risk offire :Batterymayexplodeifmistreated. Donotrecharge,disassembleordisposeofinfi re. Foruseon a flat surfaceof a type4 Xenclosureindooruse only. Use75degree conductors only Usecopperconductors only Tomake wiring connections to the power supply connector,follow the tablewith cable and torque 125 7X1/X100 AnytekconnectorsAWG24 ThesedevicesareClass2suppliedprogrammabl econtrollers(industrialPCs)fortheuse in industrial controlequipment and are intended to be (front)panel mounted (Type 1 and 4x for indooruse only).BeijerElectronics, MAEN016F5 Safety DuringInstallation Theoperatorpanel is designed forstationary installation on aplanesurface,wherethefollowingcondition sarefulfilled: no high explosive risks no strong magnetic fields no direct sunlight no large,suddentemperature changes Install theproduct accordingtotheaccompanyinginstallationin structions.

7 Ground the product according tothe accompanyinginstallation instructions. Onlyqualified personnel mayinstall the operatorpanel. Separate the high voltage, signal and supply cables. Makesurethat thevoltageand polarity of thepowersourceiscorrectbeforeconnectingt heproduct to thepoweroutlet. Peripheral equipment must beappropriatefortheapplication and DuringUse Keep the operatorpanel clean. Emergency stopand othersafety functions may notbe controlledfromtheoperator panel. Do not use toomuch force or sharp objects when touchingthekeys,touchscreen ServiceandMaintenance Onlyqualified personnel shouldcarry outrepairs. Theagreed warranty applies. Before carryingout any cleaningormaintenance operations, disconnect theequipment from theelectrical supply. Clean the display and surroundingfront cover with asoft cloth and milddetergent. Replacing the battery incorrectly mayresultin explosion. Only use batteriesrecommended by thesupplier.

8 Duringthewarrantyperiod, thebatteryneedstobe replaced byan authorized Beijer Electronics service DismantlingandScrapping Theoperatorpanel orparts thereofshall berecycledaccording to localregulations. Thefollowingcomponentscontain substancesthat might behazardoustohealth and theenvironment: lithiumbattery, electrolytic , MAEN016F6 Safety AppearanceofAirinTouchScreen Thelayerstructureofthetouchscreencontain sairandinrarecasesappearance ofbubbles can arise. This is purely cosmeticanddoes notaffectanyfunctionalityof thepanel. The appearancecan occurundercertainenvironmental conditions such as temperature, humidity, , SpaceRequirements Maximum installation plate thickness: 11 mm Space requirements in millimeterswhen installingthe operatorpanel:50 mm50 mm100 mm100 mm100 mm204 mm143 mmNote:Thedimensionsonthe drawingare , InstallationProcessThefollowingis needed: A check the delivery. If damage isfound,notify the ,foundin sectionOperator PanelDrawingsand in theTechnical Datatable,to cutacorrectopeningin thecabinet.

9 A separatecut out drawingisavailablefordownload from panel in position usingallthefasteningholes and theprovided brackets and screws:x - NmBeijerElectronics, the cables in the specified order,according to the drawing and : Ensurethattheoperatorpanelandthecontroll ersystemhavethesameelectricalgrounding(r eferencevoltagelevel),otherwiseerrorsinc ommunicationmayoccur. Theoperatorpanelmustbebroughttoambientte mperaturebeforeitisstartedup. Ifcondensationforms,ensurethattheoperato rpanelisdrybeforeconnectingittothepowero utlet. Ensurethatthevoltageandpolarityofthepowe rsource is correct. Useonlyshieldedcommunicationcables. DCRS232/RS422/RS485 24V DCADC ontrollerPowerBEthernetC Connect cable A. Connect cable B, usingan M5 screwand agroundingconductor(asshortas possible)with a cross-section of minimum Connect cable C. Connect cable D. The recommended cross-sectionofthe cable remove the laminated film overthe operatorpanel display,to avoidstaticelectricity that could damage :OnlyforiXT7 Apanelswithpartnumber630000201:Whenconne ctingtheoperatorpaneltothepoweroutletfor thefirsttime,makesurenottointerruptpower foraminimumof48hoursinordertochargetheba tterycompletely.

10 Afterthat, , ConnectionstotheControllerFor information aboutthecables to be used when connecting theoperator paneltothe controller, please refer to thehelpfilefor the driverin OtherConnectionsandPeripheralsCables,per ipheral equipment and accessories must besuitablefortheapplicationand itsenvironment. Forfurtherdetailsor recommendations, , MAEN016F11 TechnicalData3 TechnicalDataParameteriX T7 AFrontpanel,W H D 204 143 7mmCutoutdimensions,W H187 126mmMountingdepth43mm(143mmincludingcle arance)Standalonemounting VESA75 75 Note: Maximumscrew panel sealIP 20 TouchscreenmaterialPolyesteronglass, : AutoflexEBA180L(1).Touchscreenoperations 1millionfingertouchoperationsReverse sidematerialPowder-coated kgSerialportforCOM1RS232andCOM2RS422/RS4 859-pinD-subcontactwithRS232 RTS/CTS,chassis-mountedfemalewithstandar dlockingscrews4-40 UNCS erialportforCOM3RS232andCOM4RS422/RS4859 -pinD-subcontactwithRS232 RTS/CTS,chassis-mountedfemalewithstandar dlockingscrews4-40 UNCE thernet1 10 Base-T/100 Base-T(shieldedRJ45)USB1 ,maxoutputcurrent200mAProcessor400 MHzARM9 Externalstoragemedia1 SDcard(optional).