Transcription of J SLP - C A Technologies
1 HVLP AIR CAP AND FLUID NOZZLE CHART model CAPS *MAX GUN I NLET PRES S . FOR HVLPFAN CONTROLS CFM @ MAX GUN I NLETSTANDARD IN CAT PACKAVAILABLE FLUID NOZZLES TI PSNEEDLES / marking on needle23-130833-0208 (.022")40-1308 (308)23-1310W, W-PPS33-0210 (.040")40-1310 (310)23-131233-0212 (.046")40-1312 (312)23-1313W, A, PPS33-0213 (.052")40-1313 (313)23-131433-0214 (.055")40-1314 (314)23-1315W, A, PPS33-0215 (.059")40-1315 (315)23-131733-0217 (.070")40-1317 (317)23-1319W, A, PPS33-0219 (.075")40-1319 (319)23-132233-0222 (.086")40-1322 (322)Actual fluid nozzle and air cap combinations are determined by application (see application chart page 4)W = Wood *Note: Air cap test gages are available to confirm HVLP compliance.
2 A = Automotive*Gun inlet pressures may vary as required by application PPS = 3M PPS Jaguar SLP(JS LP)60-1504 (S) *GRAVITY FEED SPRAY GUNPRODUCT INFORMATIONC oating Atomization Technologies 337 South Arthur Avenue, Louisville CO 80027 Phone: , Fax: SLPO peration and Maintenance Instructions for JSLP Spray GunsOperation1. Connect air supply hose at handle of Screw the paint cup onto the gun s gravity feed fluid Fluid flow can be controlled using the fluid control knob, this restricts flow by limiting needle travel.
3 It is best to controlfluid flow by proper selection of fluid orifice size and use the fluid control knob to fine tune flow rate .4. Fan width can be adjusted using the fan control knob. Turning the knob clockwise narrows the ! Routine cleaning and maintenance is essential to insure proper gun states prohibit spraying solvent into the atmosphere and require the use of covered gun If a gun cleaner is being used, connect and clean the gun in the gun cleaner according to the If a gun cleaner is not being used:Remove air cap and clean separately using clean the gravity feed cup thoroughly, then spray clean solvent through the gun until : Gun head disassembly is not recommended for normal cleaning and head disassembly and reassembly instructions.
4 Have repair kit # 10-105 available before gun head disassemblyTo remove the nozzle carrier (5) and air cap adapter (7):1. Remove the air cap (1), fluid nozzle tip (2), fluid nozzle body (3), and needle (16).2. Remove the needle seal cartridge (17).3. Loosen the locknut (11) and remove fluid inlet (12) using a 11/16 open-end The nozzle carrier (5) and air cap adapter (7) will now slide forward from the gun body (13).Gun head reassembly1. Install a new o-ring (4 & 8) on the air cap adapter (7).2. Install the thread locknut (11) and seal (10) onto the fluid inlet (12) as far as Install a new fluid inlet seal (9) into the recess area on the nozzle carrier (5) inlet Install carrier seal (6) onto the back of the nozzle carrier (5).
5 5. Slide the nozzle carrier (5) into air cap adapter (7) and insert into the gun body (13) as far as possible. Be sure thenozzle carrier (5) extends into the hole at the back of the gun head. Install the needle seal (17) but do not Rotate the nozzle carrier (5) until the fluid inlet port in the nozzle carrier (5) is aligned with the threaded hole in thebody. While in this position, insert the fluid inlet (12) and tighten Tighten the needle seal (17) to approx. 12 Tighten the fluid inlet (12) to approx. 25 Tighten the locknut (11) to approx. 33 torque.**ITEM RT RT Air Cap Chart A ir Cap**1960-2101 Trigger2 See Air Cap ChartFluid Tip**2060-1520 Air Valve Assembly333-1202 Fluid Nozzle Body2160-302 Air Valve Poppet498-8026O-Ring*2260-125 Seal*560-J31 HNozzle Body Carrier2361-1003 Air Valve Spring*660-123 Seal*2460-119 Seal*760-34 HAir Cap A dapter2560-201 Rear Bushing860-131O-Ring*2660-204 Needle Return Spring*960-124 Seal*2760-205 Spring Seat*1060-130 Seal*2860-202 Fluid Control Knob*1160-118 Locknut2960-1510 Inlet Air Control (Optional)
6 1260-127 Fluid Inlet3060-122 Plug1360-1119 Jaguar Gun Body SLP3160-104A ir Inlet Fitting1498-0109 Allen Plug51-401 Standard 700 mL Gravity Feed Cup (Aluminum)15 See Air Cap ChartFan Control Assembly**51-400 Optional 700 mL Gravity Feed Cup (Plastic)16 See Air Cap ChartFluid Needle**51-403 Optional 1000 mL Gravity Feed Cup (Aluminum)1760-1400 Needle Seal*51-418 Gravity Cup Lid (401 & 403)1860-1033 Trigger Pivot Set51-413 Gravity Cup Lid (400)**See air cap selection chart on page 1*Indicates part included in repair kit # 10-1053233 HVLP AIR CAP TEST GAGES23-1308-G23-1310-G23-1312-GFORJSLPG UNS23-1313-G23-1314-G23-1315-G23-1322-G2 3-1317-G23-1319-GJSLP HVLP SPRAY GUNMATERIAL TYPE FLUID ORIFICE xAIR CAPMAXIMUMPATTERN WIDTHCFMVery Thin less than 16 sec.
7 Zahn #2inks , dyes, solvents, stainsThin16 to 20 sec. Zahn #2lacquers, enamels,primers, sealersMedium21 to 30 sec. Zahn #2automotive base coatenamels, primersepoxies, urethanesautomotive clear coatHeavyover 30 sec. Zahn #2heavy body primershigh solid enamelshigh solid automotive mm x mm x mm x mm x mm x mm x mm x NOZZLE / AIR CAP SELECTION CHARTSJAGUAR SLP Series - Gravity Feed Guns mm x mm x mm x 13131212 Revised 1/7/16CP-JSLP-PPSCP-JSLPEP-JSLP-(W or A) Includes:51-401700 mL Aluminum Gravity Cup98-01043/8 Socket98-0112 Ratchet Wrench60-8001 Gun Wrench98-0113 Gun Cleaning BrushAir Caps and Needles Shown on Page 1EP-JSLP-(W or A)-PPS Includes.
8 91-465650 mL PPS Cup and Collar91-466 Lids and Liners (Available in 50 Pack)91-474#2 PPS Adapter98-01043/8 Socket98-0112 Ratchet Wrench60-8001 Gun Wrench98-0113 Gun Cleaning BrushAir Caps and Needles Shown on Page 1CP-JSLP-(W or A) Includes:51-401700 mL Aluminum Gravity Cup52-300 Mini Regulator98-01043/8 Socket98-0112 Ratchet Wrench60-8001 Gun Wrench98-0113 Gun Cleaning Brush51-430 Gravity Gun HookAir Caps and Needles Shown on Page 1CP-JSLP-(W or A)-PPS Includes:91-465650 mL PPS Cup and Collar91-466 Lids and Liners (Available in 50 Pack)91-474#2 PPS Adapter52-300 Mini Regulator98-01043/8 Socket98-0112 Ratchet Wrench60-8001 Gun Wrench98-0113 Gun Cleaning BrushAir Caps and Needles Shown on Page 1