Transcription of 規格別イミュニティ試験要求の ... - jel.co.jp
1 2013 7 25 EN 61000-6-1:2007EN 61000-6-2:2005 CISPR 24:2010EN 55024:2010EN 55024:1998+ A1:2001 + A2:2003 1: 2: (ITE) (ITE) (ITE) (B) 8kV( ) 4kV( ) 8kV( ) 4kV( ) 8kV( ) 4kV( ) 8kV( ) 4kV( ) 8kV( ) 4kV( ) EN 61000-4-2EN 61000-4-2 IEC 61000-4-2:2008EN 61000-4-2:2009EN 61000-4-2:1995 (A)80 MHz-1000 MHz (3V/m), (3V/m), (1V/m),80% AM(1kHz)80 MHz-1000 MHz (10V/m), (3V/m), (1V/m), 80%AM(1kHz), ITU 3V/m 80 MHz-1000 MHz3V/m, 80% AM(1kHz)Annex 80 MHz-1000 MHz3V/m, 80% AM(1kHz)Annex 80 MHz-1000 MHz3V/m, 80% AM(1kHz)Annex EN 61000-4-3EN 61000-4-3 IEC 61000-4-3:2006 +A1:2007 + A2:2010EN 61000-4-3:2006+ A1:2008 + A2:2010EN 61000-4-3:1996 (A) ( ) (B) AC : 1kV DC L>3m: L>3 (CC) : 5kHz AC : 2kV DC L>3m: 2kV L>3m: 1kV(CC).
2 5kHzL>3m & : xDSL Annex H DC : AC : >3m & : xDSL Annex H DC : AC : >3m & : DC : AC : EN 61000-4-4EN 61000-4-4 IEC 61000-4-4:2004EN 61000-4-4:2004EN 61000-4-4:1995 (B) DC (CM) (DM) AC :2kV(CM) :1kV(DM) DC (CM) (DM) AC :2kV(CM) :1kV(DM) L>30m: 1kV (line to earth) :1kV(CM) (CM) (10/700): ( ) DC (CM) AC :2kV(CM),1kV(DM) ( ) :1kV(CM) (CM) (10/700): ( ) DC (CM) AC :2kV(CM),1kV(DM) ( ) : (CM) ( 8/20) DC : (CM) AC :2kV(CM),1kV(DM) EN 61000-4-5EN 61000-4-5 IEC 61000-4-5:2005EN 61000-4-5:2006EN 61000-4-5:1995 (A)3V(rms) 80% AM(1kHz) AC , L>3m DC 10V(rms) 80% AM(1kHz) AC , DC ,L>3m 3V(rms) 80% AM(1kHz) DC , AC L>3m 3V(rms) 80% AM(1kHz) DC , AC L>3m 3V(rms) 80% AM(1kHz) DC , AC L>3m EN 61000-4-6EN 61000-4-6 IEC 61000-4-6:2008EN 61000-4-6:2009EN 61000-4-6.
3 1996 (A)3A/m, 50/60 HzCRT 1A/m 30A/m, 50/60 HzCRT 1A/m 1A/m(rms), 50Hz 60 HzAnnex B 1A/m(rms), 50Hz 60 HzAnnex B 1A/m(rms), 50Hz 60 HzAnnex B EN 61000-4-8EN 61000-4-8 IEC 61000-4-8:2009EN 61000-4-8:2010EN 61000-4-8:1993 (B or C) : 100% red. , 1cycle B 30% red. 50/60Hz, 25/30cycle C : 100% red. 50/60Hz, 250/300cycle C : 100% red. 1cycle B 60% red. 50/60Hz,10/12cycle, 30% red. 50/60Hz, 25/30cycle C : 100% red.
4 50/60Hz, 250/300cycle C : 95% red. B 30% red. 25pr C : >95% red. 250pr C : 95% red. B 30% red. 25pr C : >95% red. 250pr C : 95% red. B 30% red. 25pr C : >95% red. 250pr C EN 61000-4-11EN 61000-4-11 IEC 61000-4-11:2004EN 61000-4-11:2004 IEC 61000-4-11:1994 ) JEL Form SA029B (2013-07-25)Page 1 of 2 Copyright (C) JEL LimitedEN 50130-4:1995+ A1:1998 + A2:2003EN 50130-4:2011EN 55014-2:1997+ A1:2001 + A2:2008 EMC ( ) EMC ( ) EMC ( ) (B) 8kV( ) 6kV( ) 8kV( ) 6kV( ) 8kV( ) 4kV( ) 4kV/ 4kV 8kV/ 4kV 8kV/ 4kV EN 61000-4-2:1995EN 61000-4-2:2009EN 61000-4-2.
5 1995EN 61000-4-2:1995+A1+A2EN 61000-4-2:1995+A1+A2EN 61000-4-2:1995+A1+A2 (A)80 MHz-2000 MHz10, 3, 1V/m,80% AM(1kHz) 80 MHz-2700 MHz10, 3, 1V/m,80% AM(1kHz) 80 MHz-1000 MHz3V/m, 80% AM(1kHz)80 MHz-1000 MHz (3V/m), (3V/m), (1V/m)80 MHz-1000 MHz (10V/m), (3V/m), (1V/m)80 MHz-1000 MHz (1V/m), (1V/m), (1V/m) EN 61000-4-3:1996EN 61000-4-3:2006+ A1:2008 + A2:2010EN 61000-4-3:2006 + A1:2008EN 61000-4-3:2002EN 61000-4-3:2002EN 61000-4-3:2002 (A)80 MHz-2000 MHz1, 3, 10V/m,1Hz PM( ON/OFF) 80 MHz-2700 MHz1, 3, 10V/m,1Hz PM( ON/OFF) EN 61000-4-3:1996EN 61000-4-3:2006+ A1:2008 + A2:2010 ( ) (B)AC : 2kV / : 1kVAC : 2kV / : 1kV : 100kHz AC : 1kV(CDN) DC : (CC) & L>3m: (CC) 2 AC : 1kVDC L>3m: 1kVI/O L>3m: I/O :1kV : 5kHzAC : 2kVDC L>3m: 2kVI/O L>3m: 15kV I/O :2kV : 5kHzAC : 1kVDC L>3m: 1kVI/O L>3m: : 5kHz EN 61000-4-4.
6 1995EN 61000-4-4:2004+A1:2010EN 61000-4-4:2004EN 61000-4-4:2004EN 61000-4-4:2004EN 61000-4-4:2004 (B)AC : , 1, 2kV(CM)AC : , 1kV(DM) / ,1kV(CM) AC : , 1, 2kV(CM)AC : , 1kV(DM) / ,1kV(CM) : 2kV(CM) : 1kV(DM) 5 AC : 1kV(CM), (DM)DC L>3m: 1kV(CM), (DM) I/O L>30m or :1kV (line to earth) I/O :1kV(CM), (DM)AC : 2kV(CM), 1kV(DM)DC L>3m: 2kV(CM),1kV(DM) I/O L>30m or : 1kV(line to earth) I/O :2kV(CM), 1kV(DM)AC : 1kV(CM), (DM) EN 61000-4-5:1995EN 61000-4-5:2006EN 61000-4-5:2006EN 61000-4-5:1995+A1:2001EN 61000-4-5:1995+A1:2001EN 61000-4-5:1995+A1:2001 (A) : , 3, 10 Vrms,80% AM(1kHz),1Hz PM( ON/OFF) : , 3, 10 Vrms,80% AM(1kHz),1Hz PM( ON/OFF) (230)MHz AM 80% AC : 3 Vrms(CDN) DC : 1 Vrms(CDN) & L>3m: 1 Vrms3V(rms), , L>3m DC I/O , I/O 3V(rms), , L>3m DC I/O , I/O 1V(rms), , L>3m DC I/O EN 61000-4-6:1996EN 61000-4-6:2009EN 61000-4-6:2007 + Corr.
7 2007EN 61000-4-6:1996+A1:2001EN 61000-4-6:1996+A1:2001EN 61000-4-6:1996+A1:2001 (A) 30A/m CRT 1A/m EN 61000-4-8:1993+A1:2001EN 61000-4-8:1993+A1:2001EN 61000-4-8:1993+A1:2001 (B or C) : +10%,-15% :30% red. 10, 20, 100, 200ms60% red. 10, 20, 100, 200ms100% red. 10, 20, 100ms : +10%,-15% :20% red. 250cycle30% red. 25cycle60% red. 10cycle100% red. 250cycle :30% red. 500ms C 60% red. 200ms C : 100% red. 10ms C : 100% red. , 1 cycle B 30% red. 50/60Hz, 25/30cycle C : 100% red. 50/60Hz, 250/300cycle C : 100% red.
8 1 cycle B 60% red. 50/60Hz, 10/12cycle, 30% red. 25/30 cycle C : 100% red. 50/60Hz, 250/300cycle C : 100% red. cycle B EN 61000-4-11:1994EN 61000-4-11:2004EN 61000-4-11:2004EN 61000-4-11:2004EN 61000-4-11:2004EN 61000-4-11:2004EN 61000-4-3:2002EN 61000-4-6:1996+A1:2001EN 61000-4-8:1993+A1:2001EN 61000-4-11:2004EN 61000-4-5:1995+A1:2001EN 61000-4-4:20042013 7 25 ) EN 61326-1:2006 (EN 50130-4 & EN 61326-1 ) EN 61000-4-2:1995+A1+A2 8kV/ 4kV80 MHz-1000 MHz (3V/m), (3V/m), (1V/m)JEL Form SA029B (2013-07-25)Page 2 of 2 Copyright (C) JEL Limit