Key: Builders Hardware Door: Swinging Security Level ...

FA Rev. 02-10A25 For more information, please call Series Deadlatches are pintumbler, solenoid-operated locks forswinging doors. Specify buildershardware cylinders and keying asfollows:NS402E & NS402 EFSK eyed one sideNS406E & NS406 EFSK eyed both sidesNote: See optional features for factory or customer-supplied key cylinders. For modelsNS400E and NS400 EFS, no cylinders are for minimum/medium securityswinging cell, corridor or administrationareas of institutions with 2" wide hollowmetal jamb remote switch is used to control thelock electrically, or it may be operatedmechanically by Builders hardwarecylinder. These locks offer theconvenience of remote, electricunlocking or locking and automaticdeadlocking when the door is ModelsUnlock when solenoid is de-energized(1):by switch or power failure, and thelatch remains retracted while the door isopen. Upon closure, with powerrestored, the latchbolt extends ModelsUnlock when solenoid is energized(1): by a momentary-contact remains retracted mechanicallyuntil the door is opened.

FA Rev. 02-10 A31 For more information, please call 210.533.1231. FOLGER ADAM ELECTRIC LOCKS HOW TO SPECIFY NS400 SERIES LOCKS 14 2 3 5 6 7 8 9 Keying 10 Location

Tags:

  Adams

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Key: Builders Hardware Door: Swinging Security Level ...

1 FA Rev. 02-10A25 For more information, please call Series Deadlatches are pintumbler, solenoid-operated locks forswinging doors. Specify buildershardware cylinders and keying asfollows:NS402E & NS402 EFSK eyed one sideNS406E & NS406 EFSK eyed both sidesNote: See optional features for factory or customer-supplied key cylinders. For modelsNS400E and NS400 EFS, no cylinders are for minimum/medium securityswinging cell, corridor or administrationareas of institutions with 2" wide hollowmetal jamb remote switch is used to control thelock electrically, or it may be operatedmechanically by Builders hardwarecylinder. These locks offer theconvenience of remote, electricunlocking or locking and automaticdeadlocking when the door is ModelsUnlock when solenoid is de-energized(1):by switch or power failure, and thelatch remains retracted while the door isopen. Upon closure, with powerrestored, the latchbolt extends ModelsUnlock when solenoid is energized(1): by a momentary-contact remains retracted mechanicallyuntil the door is opened.

2 Upon closure,the latchbolt extends automatically(mechanical latchback).Unlock when solenoid is energized(2): by a momentary-contact is electrically held retractedonly as long as control switch is tripped(no mechanical latchback). The doormust be opened while control switch isin the unlocked position. Upon closure,the latchbolt deadlocks feature is standard tohold bolt retracted for extended periods(no latchback, continuous-duty powermodulator).Unlock when solenoid is energized(3):by a momentary-contact is held electrically retracteduntil door is opened, then it extendsautomatically (electric holdback).Standards Compliance____ All deadlatch models UL1034 Burglary-resistant electric deadbolts. Non-fail-safe models, UL10B Electrically controlled single pointlocks or latches, three-hour rating, A label. ASTM F-1577 Grade 1 ImpactStandard Features_____ Instant solenoid actuation Heavyduty solenoid provides fast, audiblelatchbolt operation.

3 Fail-safe model operation Solenoidholds latchbolt extended anddeadlocked. Compact size Designed for hollowmetal frames with standard 2" face. Power modulator Allows solenoidmodels to operate on either 24 VAC or24 VDC - reduces power listed and patented (Pat. ,797,779). Two-piece, twelve-pin plug connector Simplifies wiring, allowspre-wiring of the lock opening. Heavy duty lock mechanism Designed with heavy duty, corrosion-resistant working parts tested over1,000,000 cycles. Stainless steel strike Angled lip-type, furnished with tamper-resistantscrews. Requires less force to closeand lock the door. Mechanical latchback (ModelNS400E-01) Holds latchboltretracted until door opens. Notavailable in fail-safe models. Mechanical unlocking by key Offers manual control at the door inevent of power failure or at any othertime. Stainless steel latchbolt 3/4" throw,hardened to resist ADAM ELECTRIC LOCKSKey: Builders HardwareDoor:SwingingSecurityLevel: Minimum/MediumNS400 ESOLENOID-OPERATED DEADLATCHESA26 Printed in USAFA Rev.

4 Box 2021, San Antonio, TX 78297 Ph: Fx: : Email: Holdback switch (ModelsNS400 EFS, NS400E with electricalholdback) Maintains electricalholdback. Requires a relay in thecentral control console. Finish US32D satin stainless steel. Indication switch An internal switchto monitor the positions of thedeadlock actuator. Signals Features_____ Builders Hardware cylinders Highsecurity six-pin tumbler cylinder maybe specified. Special keying requestswill be accommodated, if : Customer-supplied key cylinders may beused to adapt NS400 Series locks to a specifickeying system. These cylinders must have:a) 1-5/32" diameter, full bar stock ) 1-1/8" length, including ) Standard, removable Yale-type and all keys should be sent to SouthernFolger Detention Equipment Company and arerequired with cylinder extenders. Local electric key (LEK) Inmate keyoperates lock electrically.

5 Staff keysalways operate the lock manually andcan operate it electrically. Feature isenabled or canceled from a remotecontrol : When key cylinders for LEK are suppliedby customer, contact factory before ordering orsending cylinders. Inmate push button Allowsoperation of the lock from inside theroom or cell. May be canceled fromcentral control console. A double-pole,double-throw switch is available foradditional functions. Key cylinder extension Requiredwhen lock is keyed on the stop side ofthe door frame. Five standard lengthsare offered:JambCylinderSizeExtension4-1/2" 5"4-3/4"5" 6"5-3/4"6" 7"6-3/4"7" 8"7-3/4"8" 9"8-3/4"NOTE: Please specify appropriate cylinderextension length when ordering. Special lengthsmay be provided for other jamb factory for pricing and availability. Finish Key Cylinder: US26 DSpecifications_____ Lock case Investment-caststainless steel.

6 Latchbolt Investment-caststainless steel hardened. Latchbolt throw 3/4" Operating lever Stainless steel. Deadbolt lever/trigger bolt Investment-cast stainless steel. Strike Stainless steel stamping,angled Solenoid Tubular, continuous-duty power modulator. Voltage 24 VAC or DC, , 82 watts inrush; .25 amps6 watts seated. Indication switch SPDT, UL listed. Switch rating 5 amp @ 125 or 250 Data_____Note: Dimensions are for informationand planning purposes only, and shouldnot be used as complete details, see How toSpecify in this ADAM ELECTRIC LOCKSKey: Builders HardwareDoor:SwingingSecurityLevel: Minimum/MediumNS400 ESOLENOID-OPERATED DEADLATCHESMODELOPERATIONINDICATIONSWITC HLATCHBACKOPERATIONALSWITCHHOLDBACKLEKOP TIONCONTINUOUSDUTYMODULATORWITHWITHOUTEL ECTRICNS400E-011 AvailableStandardNS400E-042 AvailableStandardNS400E-073 AvailableStandardNS400 EFS-041 AvailableStandardFeature/Option ChartFA Rev.

7 02-10A31 For more information, please call ADAM ELECTRIC LOCKSHOW TO SPECIFYNS400 SERIES LOCKS14235678910 KeyingLocationNS400No CylinderNS402 Keyed 1 SideNS406 Keyed 2 SidesBasic ModelsDeadlatchesESolenoidMMotorMC2-Posi tion MotorDeadboltMCD2-Position MotorSwitchFunctions01 DeadlockIndication SwitchWith Latchback04 DeadlockIndication SwitchNo Latchback07 DeadlockIndication SwitchNo LatchbackAuxiliary SwitchFor ElectricHoldback09 DeadlockIndication SwitchNo LatchbackAuxiliary SwitchFor ElectricRelockMode ofOperation(E Solenoid OnlyFor Fail-Safe)NFSNon-Fail-SafeFSFail-SafeCyl inderOptionsBCPrep For BuildersHardwareCylinder,CustomerSupplie dB2 High SecurityBuilders HardwareCylinder LatchboltHanding*RHRB LHRBRHSB LHSBD eadboltHandingLHRHV oltageSolenoid24 VAC24 VDCO ptionalLocal ElectricKeyOptionalInmate PushButtonFaceplateFinishStandardUS32D11 OptionalCylinderExtensionSelect StandardOffered Length12345 67 8 9 1011NS400 EFS01B2 RHRB 24 VAC LEKPB-1 US32D Cyl.

8 "* For application handing, see the handing chart on the following in USAFA Rev. Box 2021, San Antonio, TX 78297 Ph: Fx: : Email: ADAM ELECTRIC LOCKSHOW TO SPECIFYNS400 SERIES LOCKSS pecify circled swing number when ordering.